MedPath

Nasal Intermittent Positive Pressure Ventilation During Neonatal Intubation

Not Applicable
Completed
Conditions
Newborn Morbidity
Ventilator Lung; Newborn
Respiratory Distress Syndrome
Intubation; Difficult or Failed
Desaturation of Blood
Interventions
Device: Nasal intermittent positive pressure ventilation (NIPPV) via binasal cannula during neonatal intubation
Registration Number
NCT06549283
Lead Sponsor
Muğla Sıtkı Koçman University
Brief Summary

The study aims to determine whether the use of nasal intermittent positive pressure ventilation (NIPPV) during neonatal endotracheal intubation increases the rate of successful intubation without physiological instability during all intubation attempts.

The present study was designed as a prospective, multicenter, randomized, controlled study conducted with neonates undergoing endotracheal intubation. The infants were assigned randomly to either the NIPPV group or the standard care group.

Detailed Description

The present study was designed as a prospective, multicenter, randomized, controlled trial. The study was conducted at two tertiary Neonatal Intensive Care Units (Mugla Training and Research Hospital, Mugla, Turkey; Akdeniz University School of Medicine, Antalya, Turkey) between May 2023 and May 2024. Written informed consent was obtained from the parents of each neonatal patient prior to enrollment in the study.

Participants:

Infants of a gestational age of 22-41 weeks and undergoing oral endotracheal intubation in the neonatal intensive care unit within the first 28 days of life were eligible for inclusion in the present study. The infants who required urgent intubation, those intubated in the delivery room or the operating room, infants with a heart rate of \<120/min prior to randomization, those with airway or lung anomalies, the ones with cyanotic congenital heart disease, and the ones for whom nasal intermittent positive pressure ventilation (NIPPV) treatment was contraindicated (congenital nasal anomaly, congenital diaphragmatic hernia, or abdominal wall defect) were excluded from the study.

Randomization:

Each infant was randomly assigned to either the intervention group or the standard-care group. Sequential numbers were generated in the neonatal intensive care unit's computer with an allocation ratio of 1:1. The numbers were concealed in opaque, sequentially numbered, sealed envelopes. The physician on call opened sequentially numbered sealed opaque envelopes and randomized infants to respective groups before procedure.

Definitions:

An attempt was defined as an airway maneuver, which commenced with the insertion of the laryngoscope blade (conventional) into the mouth of the patient and ended with the removal of the blade. Successful airway management was defined as the placement of an endotracheal tube in the trachea, confirmed based on chest elevation, auscultation, second independent laryngoscopy, carbon dioxide detection, and/or chest radiography. First-attempt success was defined as successful intubation by the first practitioner on the first attempt. Multiple-attempt success was defined as the requirement of over two attempts (≥3) for successful intubation. The requirement for single, two, or multiple attempts for successful intubation was defined as all intubation attempts. Severe oxygen desaturation during intubation was defined as a decrease of ≥20% in oxygen saturation relative to the highest level of oxygen saturation recorded prior to the first attempt. Bradycardia was defined as a heart rate of \<100 beats per minute. Physiological instability was defined as severe desaturation (a decrease of \>20% in oxygen saturation relative to that immediately prior to pre-laryngoscopy) or bradycardia (a heart rate of \<100 beats per minute) during the intubation attempts.

Interventions:

All neonates were monitored using a Philips monitor (IntelliVue MX450) that displayed the real-time peripheral oxygen saturation (SpO2) and heart rate prior to, during, and after the procedure. The patients were divided into two groups: the NIPPV group and the standard care group. In the NIPPV group, NIPPV was implemented during the entire intubation process (pre-intubation to intubation to the end of successful intubation). Appropriately-sized bi-nasal cannulae (Optiflow Junior, Fisher and Paykel, Auckland, New Zealand) were placed prior to laryngoscopy as interface for NIPPV implementation. NIPPV was implemented using Drager Babylog 8000 (Draeger Medicals Inc., Lubeck, Germany) or Leoni Plus (Löwenstein Medical, Bad Ems, Germany) mechanical ventilator. Non-synchronized NIPPV was implemented. NIPPV was initiated prior to intubation, with the peak inspiratory pressure set to 16-20 cmH2O (selected according to the infant's birth weight and chest wall expansion), positive-end expiratory pressure set to 6 cmH2O, breathing rate set to 40-50 breaths/min, inspiratory time set to 0.40-0.45 s, and flow rate set to 8-12 L/min. After the first successful intubation attempt, NIPPV was discontinued. Prior to laryngoscopy, the fraction of inspired oxygen (FiO2) was adjusted to maintain SpO2 above 90%. In the standard care group, the intubation attempt proceeded without NIPPV or supplemental oxygen. In the event of failure in the intubation attempt, SpO2 was increased above 90%, and the heart rate was increased above 120/min by applying positive pressure ventilation using a face mask prior to initiating the next intubation procedure. The size of the intubation tube was determined based on the baby's body weight \[12\]. Stylet was not used during intubation. Endotracheal intubations were performed either by pediatric research assistants or a neonatologist. A conventional laryngoscope with a straight blade was used for the intubation. Video laryngoscope was not used. Data accuracy was ensured by videotaping the monitor-displayed heart rate and SpO2 during the intubation procedure. After intubation, an independent assessor who was not part of the intubation team reviewed all recorded videos to document the obtained data on a case report form.

Data collection and management:

Data for demographic and clinical characteristics were collected for all patients. A pre-assigned staff member who was not a part of the intubation team noted the vital signs, adverse outcomes, and complications during and after the procedure and also collected blood gas one hour after the intubation for each patient.

Trial outcomes:

The primary outcome was successful intubation without physiological instability during all intubation attempts in the neonate. The secondary outcome was the lowest SpO2 level, lowest heart rate, bradycardia, severe desaturation, duration of severe desaturation, successful intubation on the first attempt without physiological instability, and time to successful intubation.

Sample size:

Hodgson et al. reported that the rate of successful intubation on the first attempt without physiological instability was 31% in newborns who did not receive additional respiratory support during intubation. In the present study, it was hypothesized that the success rate of intubation on the first attempt without physiological instability would increase from 31% to 54% upon the implementation of NIPPV during intubation. The sample size was calculated using the "G\*Power 3.1.9.4" program with a type I error of 5% level and a power of 80%. Accordingly, it was concluded that 75 intubation episodes were required for each group, and 150 intubation episodes were required in total.

Statistical analysis:

Statistical analysis was performed using Statistical Package for the Social Sciences (SPSS) software (version 25; Armonk, NY: IBM Corp.). The Kolmogorov-Smirnov and Shapiro-Wilk tests were conducted to determine the normal distribution of data. Student's t-test was conducted to compare the continuous parametric variables. The Mann-Whitney U-test was conducted to compare variables with non-normal distribution. Chi-squared or Fisher's exact test was conducted to analyze the categorical variables. Categorical variables were expressed as numbers (%). Normally distributed variables were expressed as mean ± standard deviation values. Non-parametric continuous variables were expressed as median values (interquartile range). The difference with p \< 0.05 was considered statistically significant.

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
146
Inclusion Criteria
  • Infants of a gestational age of 22-41 weeks and undergoing oral endotracheal intubation in the neonatal intensive care within the first 28 days of life
Exclusion Criteria
  • The infants who required urgent intubation,
  • Infants intubated in the delivery room or the operating room,
  • Infants with a heart rate of <120/min prior to randomization,
  • Infants with airway or lung anomalies,
  • Infants with cyanotic congenital heart disease,
  • Infants NIPPV treatment was contraindicated (congenital nasal anomaly, congenital diaphragmatic hernia, or abdominal wall defect)

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Arm && Interventions
GroupInterventionDescription
NIPPV groupNasal intermittent positive pressure ventilation (NIPPV) via binasal cannula during neonatal intubationNasal intermittent positive pressure ventilation (NIPPV) was implemented during the entire intubation process (pre-intubation to intubation to the end of successful intubation). Appropriately-sized bi-nasal cannulae were placed prior to laryngoscopy as interface for NIPPV implementation. Non-synchronized NIPPV was implemented. NIPPV was initiated prior to intubation, with the peak inspiratory pressure set to 16-20 cmH2O (selected according to the infant's birth weight and chest wall expansion), positive-end expiratory pressure set to 6 cmH2O, breathing rate set to 40-50 breaths/min, inspiratory time set to 0.40-0.45 s, and flow rate set to 8-12 L/min. After the first successful intubation attempt, NIPPV was discontinued. Prior to laryngoscopy, the fraction of inspired oxygen (FiO2) was adjusted to maintain SpO2 above 90%.
Primary Outcome Measures
NameTimeMethod
Successful intubation without physiological instability during all intubation attemptsOne year

Successful intubation was defined as the placement of an endotracheal tube in the trachea, confirmed based on chest elevation, auscultation, second independent laryngoscopy, carbon dioxide detection, and/or chest radiography.

Physiological instability was defined as severe desaturation (a decrease of \>20% in oxygen saturation relative to that immediately prior to pre-laryngoscopy) or bradycardia (a heart rate of \<100 beats per minute) during the intubation attempts.

All intubation attempts was defined as the requirement for single, two, or multiple attempts for successful intubation.

Secondary Outcome Measures
NameTimeMethod
Lowest SpO2 levelOne year

Lowest peripheral oxygen saturation level during intubation

Lowest heart rateOne year

Lowest heart rate during intubation

BradycardiaOne year

Bradycardia was defined as a heart rate of \<100 beats per minute

Severe desaturationOne year

Severe desaturation was defined as a decrease of ≥20% in oxygen saturation relative to the highest level of oxygen saturation recorded prior to the first attempt

Time to successful intubationOne year

Time until successful intubation is achieved. Successful intubation was defined as the placement of an endotracheal tube in the trachea, confirmed based on chest elevation, auscultation, second independent laryngoscopy, carbon dioxide detection, and/or chest radiography.

Successful intubation on the first attempt without physiological instabilityOne year

Successful intubation was defined as the placement of an endotracheal tube in the trachea, confirmed based on chest elevation, auscultation, second independent laryngoscopy, carbon dioxide detection, and/or chest radiography.

Physiological instability was defined as severe desaturation (a decrease of \>20% in oxygen saturation relative to that immediately prior to pre-laryngoscopy) or bradycardia (a heart rate of \<100 beats per minute) during the intubation attempts.

Duration of severe desaturationOne year

Duration of severe desaturation during intubation attempts. Severe desaturation was defined as a decrease of ≥20% in oxygen saturation relative to the highest level of oxygen saturation recorded prior to the first attempt

Trial Locations

Locations (2)

Mugla Training and Research Hospital, Department of Neonatology

🇹🇷

Mentese, Mugla, Turkey

Akdeniz University School of Medicine, Department of Neonatology

🇹🇷

Antalya, Turkey

© Copyright 2025. All Rights Reserved by MedPath