跳至主要内容
临床试验/NCT02173847
NCT02173847已完成不适用

Laser Assisted Procedures in Penetrating Keratoplasty: Femtosecond Laser Anvil-shaped Cuts and Laser Welding of the Surgical Wounds

Ospedale Santo Stefano2 个研究点 分布在 1 个国家目标入组 22 人开始时间: 2011年1月1日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
22
试验地点
2
主要终点
Change in best spectacle-corrected distance visual acuity (CDVA)

研究概览

简要总结

Laser- assisted procedures in penetrating keratoplasty (PK) are proposed to improve the surgical outcomes: minimally invasive procedures, improved biomechanical stability of the transplanted flap, reduction of rejection risks, reduction of inflammation, reduction of infections risk, faster healing process.

In order to achieve these goals, two different lasers were used during PK surgery:

  • a femtosecond laser to cut an anvil shaped profile
  • a diode laser to weld the surgical wound

详细描述

The femtosecond laser is used to cut an anvil-shaped laser incision used in PK. This design has the purpose to create a more structurally stable and predictable wound configuration with the aim of a faster recovery of vision and higher optical quality, compared with the conventional blade trephination and the most common laser-cut patterns. The "anvil" profile is designed as described in the followings. Donor and recipient corneal trephination are performed using a 150 kHz FS laser (iFS150TM, IntralaseTM FS Laser, Abbott Medical Optics -AMO, Santa Ana, CA, USA). As concerned iFS150 settings, we refer to the following technical parameters: in the donor graft, the outer and inner diameters of the ring lamellar cut at 350 µm in depth were set at 8.5 mm and 6.6 mm, respectively; the anterior-side cut started with an angle of 135° at a diameter of 7.7 mm, while the straight posterior side cut diameter was 6.7 mm. In the recipient eye, the diameters were designed to be 0.2 mm shorter (8.3 mm outer diameter, 6.4 mm inner diameter, 7.5 mm anterior side cut and 6.5 mm posterior side cut). After completion of the trephination, the corneal button was gently lifted from the host and the donor graft was secured in place on the recipient bed by means of 10-0 nylon cardinal sutures, which were removed after the final 16-running 10-0 nylon suture was completed. A similar FS-laser cut procedure producing a 0.2 mm-narrower corneal bed -diameter is performed on the patient's recipient eye. After completion of the trephination, the corneal button is lifted gently from the host and the donor graft is secured into place with 10-0 nylon cardinal sutures, that are removed as a running 10-0 nylon suture is placed.

The particular "anvil" shape of the graft provides a larger contact surface in between donor and recipient cornea, which enables an effective application of the diode laser welding technique of corneal wounds we have previously set up in cataract and PK applications (Menabuoni et al. 2007, Rossi et al. 2008). This laser-assisted suturing technique is based on the photothermal activation of the stromal collagen, providing an immediate sealing of the surgical wound and a good stabilization of the graft. Once the donor graft was sutured in its final position, diode laser welding was performed. A sterile saturated water solution of 10% w/v Indocyanine Green (ICG) (Pulsion Medical System AG, Munich, Germany) was prepared and applied to the walls of the surgical wound at the donor-recipient interface. A mild photothermal effect was induced by means of a near infrared diode laser (Mod. WELD 800, El.En., Calenzano, FI, Italy) that emitted at 810 nm. The laser light was delivered through a 300-micron core diameter optical fiber that was mounted on a handpiece and used "as a pencil" by the surgeon under a surgical microscope. In a slow, continuous/fluid motion, the surgeon moved the fiber tip along the wound edge at a distance of 1.5 mm from the external surface of the cornea. The power radiation emitted was a 60 mW continuous wave, which resulted in an 8 W/cm2 power density on the tissue surface. The laser welding treatment time was set at 130s.

Thanks two the combine laser assisted procedures, the possible reduction of suture materials allows a faster and improved the healing process, with minimal inflammation and reaction. Thus the combination of FS laser trephination with the diode laser welding technique may provide extremely precise, and minimally invasive surgical procedures in PK.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Treatment
盲法
None

入排标准

年龄范围
16 Years 至 75 Years(Child, Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Corneal dystrophy
  • keratoconus in its final stages
  • post-herpetic leukoma
  • corneal scar

排除标准

  • systemic diseases
  • previous corneal surgery

结局指标

主要结局

Change in best spectacle-corrected distance visual acuity (CDVA)

时间窗: 1 day, 7 days, 1 month, 3 months, 6 months, and 12 months after surgery

documentation of the visual acuity of patients

次要结局

  • Change in objective astigmatism and specular corneal topography(1 day, 7 days, 1 month, 3 months, 6 months, and 12 months after surgery)

研究者

发起方
Ospedale Santo Stefano
申办方类型
Other
责任方
Sponsor

研究点 (2)

Loading locations...

相似试验