NCT05876936终止不适用

A Prospective, Open Label Study to Assess the 24-hour Intraocular Pressure Pattern Recorded With Triggerfish® in Patients With Open Angle Glaucoma Before and After DSCI

University Hospital, Geneva1 个研究点 分布在 1 个国家目标入组 5 人开始时间: 2013年12月1日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
终止
入组人数
5
试验地点
1
主要终点
Changes between the nycthemeral IOP patterns recorded with TF during two 24-hour periods in patients with OAG

研究概览

简要总结

A prospective, open label study to assess the 24-hour intraocular pressure pattern recorded with SENSIMED Triggerfish® in patients with open angle glaucoma before and after deep sclerectomy with collagen implant

详细描述

This is a prospective, open label study to assess the 24-hour IOP pattern recorded by SENSIMED Triggerfish® in Open Angle Glaucoma (OAG) patients before and after deep sclerectomy with collagen implant (DSCI).

After having signed and dated the patient informed consent form, patients will undergo an initial ophthalmic examination. The contact lens sensor (CLS) SENSIMED Triggerfish® will be placed on the study eye as selected for DSCI, for a baseline 24-hour IOP pattern recording session (S1), within 7 days preceding the surgical procedure. Patients will remain ambulatory and will be encouraged to follow a schedule as close to his/her usual lifestyle as possible. A patient diary will be distributed for the capture of patient activities during the IOP pattern recording. Upon completion of S1, the contact lens sensor (CLS) SENSIMED Triggerfish® will be removed and a final ophthalmic examination will be conducted. The patient diary will be collected and concomitant medication will be reported. The surgery will be scheduled within 2 days following S1.

Unless contraindicated (e.g. large filtering bleb precluding placement of the contact lens sensor (CLS) SENSIMED Triggerfish®), patients will undergo a second 24-hour contact lens sensor (CLS) SENSIMED Triggerfish® IOP pattern recording session (S2) on the study eye 3 months after the surgical procedure. S2 will start at the same time of day ± 30 min as S1, preferably at a time that allows for sufficient recording of the wake-to-sleep and the sleep-to-wake phases. Prior to S2 and upon completion of thereof, ophthalmic examinations will be conducted and patient diary will be collected. In addition, any specifics regarding the DSCI and medication will be reported. A visual field (VF) assessment will also be performed to evaluate the changes after deep sclerectomy with collagen implant.

Patients will undergo a third 24-hour SENSIMED Triggerfish® IOP pattern recording session (S3) on the study eye 12 months after the surgical procedure. S3 will start at the same time of day ± 30 min as S2, preferably at a time that allows for sufficient recording of the wake-to-sleep and the sleep-to-wake phases. Prior to S3 and upon completion of thereof, ophthalmic examinations will be conducted and patient diary will be collected. In addition, any specifics regarding the deep sclerectomy with collagen implant (DSCI) and medication will be reported. A visual field assessment will also be performed to evaluate the changes after deep sclerectomy with collagen implant (DSCI).This concludes the study for the patients.

Hence, the overall study duration for the patient is limited to 13 months. The study has been planned to recruit at least 40 eligible patients within 11 months from initiation. Hence the overall study duration from the first patient accrued into the study until last patient out equates to about 24 months or less. Allowing for a database lock within 4 weeks of study completion, a preliminary statistical report on the primary efficacy endpoint is foreseen within 2 weeks thereafter.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Prevention
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者
否

入选标准

  • •Diagnosis of Open Angle Glaucoma (OAG)
  • •Documented glaucomatous Visual Field damage with MD more negative than -2 dB
  • •Progressing glaucomatous damage justifying a deep sclerectomy with collagen implant (DSCI)
  • •Aged ≥18 years, of either sex
  • •Not more than 6 diopters spherical equivalent on the study eye
  • •Have given written informed consent, prior to any investigational procedures

排除标准

  • •• History of ocular surgery within the last 3 months on the study eye
  • •History of ocular laser treatment on the study eye
  • •Corneal or conjunctival abnormality precluding contact lens adaptation on the study eye
  • •Severe dry eye syndrome on the study eye
  • •Patients with allergy to corneal anesthetic
  • •Patients with contraindications for silicone contact lens wear
  • •Patients not able to understand the character and individual consequences of the investigation
  • •Participation in other clinical research within the last 4 weeks
  • •Any other contra-indication listed in the SENSIMED Triggerfish® user manual

研究组 & 干预措施

contact lens sensor Triggerfish® in patients selected for deep sclerectomy with collagen implant

Other

The contact lens sensor (CLS) SENSIMED Triggerfish® in will be placed on the study eye as selected for deep sclerectomy with collagen implant (DSCI)

干预措施: contact lens sensor (CLS) SENSIMED Triggerfish® (Device)

结局指标

主要结局

Changes between the nycthemeral IOP patterns recorded with TF during two 24-hour periods in patients with OAG

时间窗: Baseline, 3 months and 12 months

Nycthemeral IOP patterns differences will be evaluated with SENSIMED Triggerfish® recording for two 24hs periods in Open Angle Glaucoma patients comparing from baseline to 3 and 12 months

次要结局

  • Changes in diurnal and nocturnal IOP patterns(3 months and 12 months after deep sclerectomy with collagen implant (DSCI))
  • Changes in visual field(3 months and 12 months after deep sclerectomy with collagen implant (DSCI))
  • Number of Adverse Events(3 months and 12 months after deep sclerectomy with collagen implant (DSCI))

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Dr. Kaweh Mansouri

Chef de clinique

University Hospital, Geneva

研究点 (1)