Skip to main content
Clinical Trials/NCT03226535
NCT03226535
Unknown
Not Applicable

Ultrasound-CT Fusion System for Interventional Radiology Procedures

Clear Guide Medical1 site in 1 country20 target enrollmentJune 22, 2017

Overview

Phase
Not Applicable
Intervention
Not specified
Conditions
CT Guided Biopsy
Sponsor
Clear Guide Medical
Enrollment
20
Locations
1
Primary Endpoint
Number of CT scans or CT fluoroscopic images
Last Updated
8 years ago

Overview

Brief Summary

The objective of this research is to use the Clear Guide SCENERGY technology, an FDA approved Ultrasound-CT fusion imaging system, that allows the user to fuse CT images onto a real-time ultrasound that is being performed on the patient. This fusion system will be used to perform ultrasound guided needle placements for patients undergoing percutaneous CT guided needle-based intervention. This study will consist of 20 patients, 10 patients using the CGM SCENERGY US-CT system and 10 patients using guidance only. The primary goal of the study is to prove that the new imaging fusion system is comparable to using either CT or US guidance alone to guide needle placement.

Detailed Description

A simple 20 patient study will be performed using the CG SCENERGY system. This fusion system will be used to perform image guided needle placements for patients undergoing percutaneous CT guided needle-based intervention (CT guided biopsy, CT guided drain placement within the abdomen or pelvis, and CT guided injection of muscle or nerve within the pelvis). Only patients who are already scheduled for a CT guided procedure will be screened. The study design is as follows: * 10 patients will have their procedure performed using the CGM SCENERGY US-CT fusion system and 10 patients will have their procedure performed using CT guidance only. * Proper informed consent will be obtained * Perform a CT scan with the optical adhesive skin markers in place. Markers are placed around the expected site of needle skin entry. * The first 10 patients Group#1 (1-10) will be assigned to using the SCENERGY fusion system to complete the needle placement, and the next 10 patients Group #2 (11-20) will be assigned of continuing with CT guidance only to complete the needle placement. * If in Group #1, the procedure will proceed as usual using the SCENERGY system to guide the needle to target. If in the Group #2, CT guidance will be used to place the needle to target. * Once the needle is at the target, a confirmatory CT will be performed. * If the target is reached (i.e., the software directed the interventional radiologist to the right place, e.g. for correctly biopsying a lesion), the trial is considered a "success" and the procedure continues as normal. * If the needle is not in the right place, the trial is considered a "failure", and the procedure continues as normal without using the CGM software any further.

Registry
clinicaltrials.gov
Start Date
June 22, 2017
End Date
June 22, 2018
Last Updated
8 years ago
Study Type
Interventional
Study Design
Parallel
Sex
All

Investigators

Sponsor
Clear Guide Medical
Responsible Party
Sponsor

Eligibility Criteria

Inclusion Criteria

  • Undergoing percutaneous CT guided needle-based intervention (CT guided biopsy, CT guided drain placement within the abdomen or pelvis, and CT guided injection of muscle or nerve within the pelvis)
  • Able to give written informed consent

Exclusion Criteria

  • Unable to give informed consent
  • Patients undergoing CT guided needle-based interventions other than the procedures mentioned in the inclusion criteria
  • Prisoners, pregnant women, and children

Outcomes

Primary Outcomes

Number of CT scans or CT fluoroscopic images

Time Frame: Immediately following intervention (within 2 hours)

Secondary Outcomes

  • Total procedure time(Immediately following intervention (within 2 hours))
  • Time to target(Immediately following intervention (within 2 hours))
  • Success of needle placement(Immediately following intervention (within 2 hours))