Visual and Refractive Outcomes of The ClarVista HARMONI™ Modular Intraocular Lens System (HMIOL)
- Conditions
- AphakiaCataract
- Interventions
- Device: Harmoni Modular Intraocular LensProcedure: Optic Exchange
- Registration Number
- NCT03681886
- Lead Sponsor
- ClarVista Medical
- Brief Summary
The purpose of this study was to evaluate visual and refractive outcomes with the use of the HARMONI™ Modular Intraocular Lens (HMIOL) System implantation, assembly, and optic exchange in subjects undergoing cataract surgery.
- Detailed Description
All subjects were implanted with the HARMONI™ Modular Intraocular Lens (HMIOL) System in the right eye, left eye, or both eyes based on the best interest of the subject and the clinical judgment the Investigator (Day 0, primary implantation) (Cohort 1). At Month 1 post primary implantation, subjects were given the option to undergo an optic exchange procedure. Subjects who underwent the optic exchange (Cohort 2) (Day 0, optic exchange) were followed for an additional month. Subjects who did not undergo an optic exchange were exited from the study, except at 1 site, which followed subjects up to Month 12.
Alcon Research, LLC, acquired ClarVista Medical in 2017. This study was designed and conducted by ClarVista Medical, Inc. The study results were collected, analyzed, and provided by ClarVista Medical, Inc. to Alcon Research, LLC.
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 150
- Able to understand and sign an approved Informed Consent Form (ICF);
- Willing and able to return for scheduled treatment and follow-up examinations;
- Planned removal of cataracts (cortical, nuclear, subcapsular, or a combination) by manual phacoemulsification cataract extraction;
Key
- Any ocular conditions which could affect the stability of the IOL in either eye;
- Traumatic or congenital cataract;
- Pregnancy or planned pregnancy during the study period;
- Medications that may confound the outcome or increase risk to the subject;
- Any clinical finding or intraocular complication during primary cataract surgery or Implantation of the lens system likely to increase complications or risk to the subject;
- Other protocol-specified exclusion criteria may apply.
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- SINGLE_GROUP
- Arm && Interventions
Group Intervention Description Primary Implantation (Cohort 1) Harmoni Modular Intraocular Lens Primary implantation with HMIOL through Month 1 visit, followed by study exit. 1 site followed up to Month 12. Optic Exchange (Cohort 2) Harmoni Modular Intraocular Lens Subset of Cohort 1 with optic exchange at Month 1 post primary implantation, followed up to Month 1 post optic exchange Optic Exchange (Cohort 2) Optic Exchange Subset of Cohort 1 with optic exchange at Month 1 post primary implantation, followed up to Month 1 post optic exchange
- Primary Outcome Measures
Name Time Method Percentage of Eyes With Uncorrected Distance Visual Acuity (UCDVA) by Visit - Cohort 1 Day 1 post primary implantation, Week 1 post primary implantation, Month 1 post primary implantation, Month 3 post primary implantation, Month 6 post primary implantation, Month 12 post primary implantation Visual acuity of the eye was tested while reading charts at 20-foot equivalent distance from the participant with an optical infinity adjustment of +0.25 diopter (D). UCDVA was recorded in Snellen, with 20/20 considered to be 'normal' vision. A visual acuity of 20/40 means the participant is able to read a certain size letter 20 feet away that a person with 'normal' vision would be able to read from 40 feet away. A larger denominator, therefore, indicates a lower visual acuity. No formal statistical hypothesis testing was planned.
Percentage of Eyes With Uncorrected Distance Visual Acuity (UCDVA) by Visit - Cohort 2 Day 0 pre optic exchange, Day 1 post optic exchange, Week 1 post optic exchange, Month 1 post optic exchange Visual acuity of the eye was tested while reading charts at 20-foot equivalent distance from the participant with an optical infinity adjustment of +0.25 diopter (D). UCDVA was recorded in Snellen, with 20/20 considered to be 'normal' vision. A visual acuity of 20/40 means the participant is able to read a certain size letter 20 feet away that a person with 'normal' vision would be able to read from 40 feet away. A larger denominator, therefore, indicates a lower visual acuity. No formal statistical hypothesis testing was planned. The optic exchange occurred 1 month following primary implantation with HMIOL.
Percentage of Eyes With Best Corrected Distance Visual Acuity (BCDVA) by Visit - Cohort 1 Baseline (Day -90 to Day 0 preoperative), Week 1 post primary implantation, Month 1 post primary implantation, Month 3 post primary implantation, Month 6 post primary implantation, Month 12 post primary implantation Visual acuity of the eye was tested while reading charts at 20-foot equivalent distance from the participant with subject manifest refraction in place. BCDVA was recorded in Snellen, with 20/20 considered to be 'normal' vision. A visual acuity of 20/40 means the participant is able to read a certain size letter 20 feet away that a person with 'normal' vision would be able to read from 40 feet away. A larger denominator, therefore, indicates a lower visual acuity. No formal statistical hypothesis testing was planned.
Mean Manifest Refraction Spherical Equivalent (MRSE) by Visit - Cohort 2 Baseline (Day 0 pre optic exchange), Week 1 post optic exchange, Month 1 post optic exchange A manifest refraction (manual vision test) was conducted using letter charts and a phoropter. The subject was manually refracted to his/her best correction. The manifest refraction spherical equivalent (MRSE) was measured in diopters (D) and calculated as follows: sphere + 1/2 cylinder. A less negative value indicates a more accurate IOL power calculation. No formal statistical hypothesis testing was planned.
Mean Manifest Refraction Spherical Equivalent (MRSE) by Visit - Cohort 1 Baseline (Day -90 to Day 0 preoperative), Week 1 post primary implantation, Month 1 post primary implantation, Month 3 post primary implantation, Month 6 post primary implantation, Month 12 post primary implantation A manifest refraction (manual vision test) was conducted using letter charts and a phoropter. The subject was manually refracted to his/her best correction. The manifest refraction spherical equivalent (MRSE) was measured in diopters (D) and calculated as follows: sphere + 1/2 cylinder. A less negative value indicates a more accurate IOL power calculation. No formal statistical hypothesis testing was planned.
Number of Secondary Surgical Interventions (SSI) (Other Than Optic Exchange) Cohort 1: Up to one month post primary implantation, with one site followed up to 12 months. Cohort 2: Up to one month post exchange, for a total of up to 2 months. A secondary surgical intervention (SSI) was defined as a surgical procedure that occurred after primary implantation and was conducted for the purpose of resolving residual refractive error (RRE) and optimizing visual outcomes, as determined by the investigator. No formal statistical hypothesis testing was planned.
Percentage of Eyes With Best Corrected Distance Visual Acuity (BCDVA) by Visit - Cohort 2 Baseline (Day 0 pre optic exchange), Week 1 post optic exchange, Month 1 post optic exchange Visual acuity of the eye was tested while reading charts at 20-foot equivalent distance from the participant with subject manifest refraction in place. BCDVA was recorded in Snellen, with 20/20 considered to be 'normal' vision. A visual acuity of 20/40 means the participant is able to read a certain size letter 20 feet away that a person with 'normal' vision would be able to read from 40 feet away. A larger denominator, therefore, indicates a lower visual acuity. No formal statistical hypothesis testing was planned.
Number of Surgeon Responses to Optic Exchange Surgery Question: How Would You Rate the Surgical Difficulty of the Optic Disassembly? - Cohort 2 Day 0 post-exchange The surgeon's response was collected on a study-specific questionnaire after each surgery. No formal statistical hypothesis testing was planned.
Number of Surgeon Responses to Primary Surgery Question: How Would You Rate the Surgical Difficulty of the Base Implantation? - All HMIOL Cohort Day 0 primary implantation The surgeon's response was collected on a study-specific questionnaire after each surgery. No formal statistical hypothesis testing was planned.
Number of Surgeon Responses to Optic Exchange Surgery Question: How Would You Rate the Surgical Difficulty of the Optic Implantation and Assembly (Exchange)? - Cohort 2 Day 0 post-exchange The surgeon's response was collected on a study-specific questionnaire after each surgery. No formal statistical hypothesis testing was planned.
Number of Surgeon Responses to Primary Surgery Question: How Would You Rate the Surgical Difficulty of the Optic Implantation and Assembly? - All HMIOL Cohort Day 0 primary implantation The surgeon's response was collected on a study-specific questionnaire after each surgery. No formal statistical hypothesis testing was planned.
Number of Surgeon Responses to Optic Exchange Surgery Question: How Would You Rate the Surgical Difficulty of the Optic Explantation? - Cohort 2 Day 0 post-exchange The surgeon's response was collected on a study-specific questionnaire after each surgery. No formal statistical hypothesis testing was planned.
Number of Device Deficiencies Cohort 1: Up to one month post primary implantation, with one site followed up to 12 months. Cohort 2: Up to one month post exchange, for a total of up to 2 months. A device deficiency was defined as a failure of the device to meet its performance specifications or expectations, or otherwise not perform as intended. This could include either a malfunction or damage to the device or any part thereof, regardless of the source of malfunction or damage, including user error, and regardless of the presence of injury (or lack thereof) to subject, user, or bystander. No formal statistical hypothesis testing was planned.
- Secondary Outcome Measures
Name Time Method