跳至主要内容
临床试验/NCT05974540
NCT05974540已完成不适用

Ultrasound Versus Physical Examination for Cricothyroid Membrane Determination in Pediatric Patients

Marmara University1 个研究点 分布在 1 个国家目标入组 100 人开始时间: 2023年7月1日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
100
试验地点
1
主要终点
Distance between palpation-based and USG-based determination of the cricothyroid membrane

研究概览

简要总结

Emergency cricothyroidotomy is a very important technique to ensure airway safety in acute situations. Problem in identifying the cricothyroid membrane is a major contributor to high failure, as the most common complication during cricothyrotomy is the misplacement of the cannula. The success rate of emergency airway access performed by anesthesiologists and emergency medicine specialists was found to be low due to the low frequency of the procedure. The aim in this study is to compare the palpation method with the ultrasonugraphy (USG)-based method in determining the cricothyroid membrane. The hypothesis is that USG is more successful than palpation in identifying the cricothyroid membrane. In addition, the relationship between difficult intubation and measurements such as the cricothyroid membrane length, the cricoid cartilage and the skin distance, the distance between the cricoid cartilage and the second tracheal ring will be evaluated.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
1 Year 至 18 Years(Child, Adult)
性别
All
接受健康志愿者

入选标准

  • American Society of Anaesthesiologists (ASA) I and II physical status
  • Elective pediatric surgery
  • Patients going to be intubated

排除标准

  • ASA III or above physical status
  • Emergency surgery
  • Patients having tracheostomy
  • Patients going to have laryngeal mask

结局指标

主要结局

Distance between palpation-based and USG-based determination of the cricothyroid membrane

时间窗: On the 1 day of the surgery. After the anesthesia induction and intubation.

Regarding the determination point of the cricothyroid membrane the distance between palpation-based method performed by pediatric surgeon and USG-based method performed by anesthesiologist will be measured.

次要结局

  • Cricothyroid membrane length(On the 1 day of the surgery. After the anesthesia induction and intubation.)
  • Skin distance from cricoid cartilage(On the 1 day of the surgery. After the anesthesia induction and intubation.)
  • Distance between cricoid cartilage and 2nd tracheal ring(On the 1 day of the surgery. After the anesthesia induction and intubation.)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Ruslan Abdullayev

Assoc. Prof.

Marmara University

研究点 (1)

Loading locations...