跳至主要内容
临床试验/NCT05187988
NCT05187988已完成不适用

Comparative Study Between Two Different Approaches of Brachial Plexus Block: Supraclavicular Approach and Retroclavicular Approach

Sohag University1 个研究点 分布在 1 个国家目标入组 100 人开始时间: 2022年1月5日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
入组人数
100
试验地点
1
主要终点
Block success rate

研究概览

简要总结

In this study investigators will compare two different approaches of brachial plexus block ;supraclavicular approach and retroclavicular approach regarding success rate, duration of block, complications

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 60 Years(Adult)
性别
All
接受健康志愿者
是

入选标准

  • •100 patients doing distal arm surgery, elective , 18 to 60 years old , will be included in double blinded randomized study.

排除标准

  • •Patient refusal .
  • •local infection or deformity at the block site.
  • •Patient with significant neurological , psychiatric or neuromuscular disease.
  • •Pregnancy or lactating women .
  • •Coagulopathy .
  • •Morbid obesity .
  • •History of allergy to local anaesthetics

研究组 & 干预措施

Supraclavicular approach group

Active Comparator

probe placed firmly over the supraclavicular fossa, parallel to the clavicle to obtain a short-axis view of the divisions of the brachial plexus and the subclavian artery, lying on the first rib After skin infiltration with lidocaine 2% a 23-gauge 70mm block needle inserted in-plane with the ultrasound beam, in a lateral-to-medial direction, until the needle tip's positioned at the junction of the first rib and subclavian artery

干预措施: supraclavicular brachial plexus block (Procedure)

Retroclavicular approach group

Active Comparator

the probe will be placed below and perpendicular to the clavicle, in a paramedian sagittal plane, medial to the coracoid process, to obtain a short-axis view of the cords of the brachial plexus and the axillary vessels. The needle will be then inserted in the supraclavicular fossa, approximately 1 cm posteriorly to the clavicle, and advanced in plane and strictly parallel to the ultrasound transducer. After passing the initial blind zone of about 2 cm caused by the acoustic shadow of the clavicle, the needle tip is constantly seen, until it is positioned posterior to the axillary artery

干预措施: Retroclavicular brachial plexus block (Procedure)

结局指标

主要结局

Block success rate

时间窗: one year

Investigator will compare success rate of both types of block and which one is more likely to be successfully administrated

Duration of sensory and motor blockade

时间窗: one year

Time which each procedure will take to block sensory and motor stimuli

Complications

时间窗: one year

Investigators will compare complications like pneumothorax,nerve injury,bleeding and which one is more likely to cause complications

次要结局

  • Duration of procedure(one year)
  • Number of needle passes(one year)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Mahmoud Adel Mahmoud

resident doctor at anasthesia department sohag university hospital

Sohag University

研究点 (1)

Loading locations...

相似试验