Clinical Investigation of the Medtronic EnTrust™ Implantable Cardioverter Defibrillator (ICD), Model D153ATG
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- 入组人数
- 500
- 试验地点
- 41
- 主要终点
- Safety and efficacy at three months.
研究概览
简要总结
People who have a dangerously fast heart beat, or whose heart is at risk of stopping beating, may be in need of an electronic device called an implantable cardioverter defibrillator (ICD). An ICD is implanted surgically just under the skin in the upper chest area and it sends a strong electrical impulse, or shock, to the heart to return it to a normal rhythm.
The purpose of this study was to evaluate the safety and efficacy of the EnTrust ICD device. A feature of this device allows it to send small, painless electrical impulses (Anti-tachycardia pacing or ATP) to the heart instead of shocking it out of a rhythm that is too fast. Stopping a dangerous heart rhythm this way does not cause any pain whereas a shock to the heart can feel like a punch in the chest. This device also allows the heart to beat on its own when it can and helping it (by pacing, or sending it electrical signals) when it needs help. This feature is important because previously studies have shown that pacing the heart too often can increase the risk for heart failure or for atrial fibrillation (having too rapid of heart beats in the atrium).
This study is now complete and the device has since been approved by the FDA.
研究设计
- 研究类型
- Interventional
- 分配方式
- Non Randomized
- 干预模型
- Single Group
- 主要目的
- Treatment
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Subjects with failure but no symptoms (NYHA Class I) or subjects with mild heart failure that only sometimes interferes with daily activities (NYHA Class II)
- •Subjects who have, or are risk of having, a heart beat that is too fast and his/her doctor has determined he/she needs an implantable cardioverter defibrillator (ICD)
- •Subjects who have, or are at risk of developing, rapid beats in the upper chambers of the heart (atrial tachyarrhythmias)
排除标准
- •Subjects with rapid heart beats in their ventricles (lower chambers of the heart) associated only with reversible causes
- •Subjects with mechanical tricuspid heart valves (A structure in the heart, located between the right atrium and right ventricle, which allows blood to flow down from the atrium into the ventricle.)
结局指标
主要结局
Safety and efficacy at three months.
次要结局
- To evaluate how well the device distinguished between arrhythmias originating in the atrium versus those that originate in the ventricle.
- To evaluate how well the anti-tachycardia pacing function works.
- To observe the overall performance of the device system.