Does the Cap Increase the Finding of Polyps When Water Exchange Colonoscopy is Used

Not Applicable
Recruiting
Conditions
Colonoscopy
Polyp of Colon
Interventions
Device: CAP-straight
Device: CAP-daisy
Other: water
Registration Number
NCT03566615
Lead Sponsor
VA Greater Los Angeles Healthcare System
Brief Summary

This is a study to compare two different, but normally, used methods of colonoscopy in patients that require a routine or repeat colonoscopy. There will be three arms in this study: WE water control, water plus Cap-1, and water plus Cap-2. The patient will prepare himself/herself for the colonoscopy as per normal instructions and he/she will be given the information for the study at that time so that he/she can make a decision to participate in the study. The control method will use water instead of air inserted into the colon. The study method will use a new accessory, a cap that will fit onto the end of the colonoscope plus water during the procedure. This study will also confirm if using the cap method with water is a better way of detecting polyps in the colon and possibly cancer.

Detailed Description

This will be a multi-site, multi-national, unblinded investigators, prospective Random Control Trial (RCT). Randomization (WE, WE Cap-1, WE Cap-2) will be based on computer generated random numbers placed inside opaque sealed envelopes. The envelope (in pre-arranged order) will be opened to reveal the code when the colonoscopist is ready to insert the endoscope to begin the examination. This will be a comparison of two different methods with three arms (WE, WE Cap-1, WE Cap-2) to see which one is better at detecting adenomas.

Patients who are willing to participate will sign an informed consent before starting the colonoscopy procedure. Separate parallel randomization will be set up at each site, stratified by investigator and type of colonoscopy (screening or surveillance). Mode of sedation will include unsedated (China, US West Los Angeles VA), minimally sedated (Taiwan), on demand sedation (Italy, Czech Republic, US West Los Angeles VA), conscious sedation (US Sacramento VA and Palo Alto VA) or full sedation with propofol (Taiwan). Randomization (prepared by statistics consultant) will be carried out by the method of random permuted block design (based on computer generated random numbers) with variable block sizes of 3 and 6. Gender will be used as a stratification factor.

Control Method: One arm of the study will include sedated/unsedated colonoscopy with water (WE) as the control method. Residual air in the colon will be removed and water will be infused to guide insertion through an airless lumen. Infused water will be removed by suction, along with residual fecal debris, predominantly during insertion.

Study method: The other two arms entail the addition of a simple commercially available accessory to the colonoscopy device: Cap -1 (Disposable Distal Attachment) or Cap-2, fitted to the colonoscope per manufacturer instruction. The two arms include sedated/unsedated colonoscopy with either a Cap-1 plus water or Cap-2 plus water.

Recruitment & Eligibility

Status
RECRUITING
Sex
All
Target Recruitment
1630
Inclusion Criteria
  1. Male and female 50-75 yrs of age.
  2. Positive screening for Fecal Immunochemical Test (FIT) or Fecal Occult Blood Test (FOBT).
  3. Subjects willing to undergo routine screening and surveillance colonoscopy.
Exclusion Criteria
  1. Patients who decline to provide informed consent.
  2. Patients known to have colonic obstruction, inflammatory bowel disease, or active GI bleeding requiring interventions.
  3. Patients know to have prior history of severe diverticulitis/diverticulosis.

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Arm && Interventions
GroupInterventionDescription
CAP-straightCAP-straightA straight transparent cap was fitted to the colonoscope per manufacturer instruction.Residual air in the colon will be removed, water will be infused to guide insertion through an airless lumen. Infused water will be removed by suction, along with residual fecal debris, predominantly during insertion.
CAP-daisyCAP-daisyA daisy cap transparent cap was fitted to the colonoscope per manufacturer instruction.Residual air in the colon will be removed, water will be infused to guide insertion through an airless lumen. Infused water will be removed by suction, along with residual fecal debris, predominantly during insertion. Note: IRB Approval date for the use of Endocuff at St. Barbara Hospital, Iglesias (CA), Italy, was obtained on 3/8/2017. IRB Approval date for the use of Endocuff at Evergreen General Hospital, Taipei, Taiwan, was obtained on 3/18/2021.
WaterwaterResidual air in the colon will be removed, water will be infused to guide insertion through an airless lumen. Infused water will be removed by suction, along with residual fecal debris, predominantly during insertion.
CAP-daisywaterA daisy cap transparent cap was fitted to the colonoscope per manufacturer instruction.Residual air in the colon will be removed, water will be infused to guide insertion through an airless lumen. Infused water will be removed by suction, along with residual fecal debris, predominantly during insertion. Note: IRB Approval date for the use of Endocuff at St. Barbara Hospital, Iglesias (CA), Italy, was obtained on 3/8/2017. IRB Approval date for the use of Endocuff at Evergreen General Hospital, Taipei, Taiwan, was obtained on 3/18/2021.
CAP-straightwaterA straight transparent cap was fitted to the colonoscope per manufacturer instruction.Residual air in the colon will be removed, water will be infused to guide insertion through an airless lumen. Infused water will be removed by suction, along with residual fecal debris, predominantly during insertion.
Primary Outcome Measures
NameTimeMethod
Adenoma detection rate2 years

The proportion of individuals undergoing a complete screening colonoscopy who have one or more adenomas, or polyps, detected.

Secondary Outcome Measures
NameTimeMethod
Cecal intubation2 hours: Data collected during colonoscopy procedure

Visualization of ileocecal valve/appendix orifice and the medial wall of the cecum with colonoscope tip touching floor of cecum

Willing to repeat2 hours: Data collected during colonoscopy procedure

Visual analogue scale (0=not willing, 10=willing)

Boston bowel preparation score2 hours: Data collected during colonoscopy procedure

Three segments (Right, transverse, left colon), each with 0 to 3 (poor to excellent); total scores = sum (10 point scale)

Cecal intubation time2 hours: Data collected during colonoscopy procedure

Total time from insertion into the anus to arrival in the cecum

Visual analogue scale (0=not satisfied, 10=very satisfied)2 hours: Data collected during colonoscopy procedure

Patient satisfaction

Trial Locations

Locations (7)

St. Barbara Hospital

🇮🇹

Iglesias, Italy

Hualien Tzu Chi Hospital

🇨🇳

Hualien City, Taiwan

Veterans Affairs Palo Alto Healthcare System

🇺🇸

Palo Alto, California, United States

Dalin Tzu Chi General Hospital

🇨🇳

Chiayi City, Taiwan

Xijing Hospital of Digestive Diseases

🇨🇳

Xian, China

Sacramento VAMC, VA Northern California Healthcare System

🇺🇸

Mather, California, United States

Evergreen General Hospital

🇨🇳

Taipei, Taiwan

© Copyright 2025. All Rights Reserved by MedPath