Short-term Effects of Humidification Devices on Respiratory Pattern and Work of Breathing During Invasive Ventilation

Not Applicable
Completed
Conditions
Chronic Respiratory Failure
Interventions
Device: Hygrovent Gold
Device: Heated and moisture exchanger (HME)
Device: Heated humidifier (HH)
Registration Number
NCT02499796
Lead Sponsor
Fondazione Salvatore Maugeri
Brief Summary

This study compares the short-term effects of a new humidification system (Hygrovent Gold) and two other humidification devices (heated and moisture exchanger and heated humidifier) on respiratory pattern and work of breathing, during invasive ventilation.

Detailed Description

Three humidifying devices are commonly and indifferently used during mechanical ventilation, but their impact on respiratory mechanics and, eventually, mechanical ventilation efficacy, particularly in patients highly dependent from mechanical ventilation, are not superimposable.

It has already been described that heated and moisture exchangers (HME), increasing dead space, can negatively affect ventilatory function and gas exchange, in comparison to heated humidifiers (HH).

The Hygrovent Gold, mainly because of its position between the tracheostomy and the Y-piece of the ventilatory circuit and its structure, may lead to analogous or even worse effects, determining and increase in inspiratory resistances and dead space and consequently an increase in the work of breathing.

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
15
Inclusion Criteria
  • Chronic hypercapnic respiratory failure (PaCO2 of 45 mmHg or more)
  • Long-term mechanical ventilation via tracheostomy
  • Clinical stability
Exclusion Criteria
  • Non collaborative subjects
  • Acute respiratory failure
  • Haemodynamic instability
  • Encephalopathy

Study & Design

Study Type
INTERVENTIONAL
Study Design
SINGLE_GROUP
Arm && Interventions
GroupInterventionDescription
Single ArmHygrovent GoldEvery patient receives 20 minutes of invasive mechanical ventilation with each of the three humidification systems in random sequence: * Heated and moisture exchanger (HME) * Heated humidifier (HH) * Hygrovent Gold
Single ArmHeated and moisture exchanger (HME)Every patient receives 20 minutes of invasive mechanical ventilation with each of the three humidification systems in random sequence: * Heated and moisture exchanger (HME) * Heated humidifier (HH) * Hygrovent Gold
Single ArmHeated humidifier (HH)Every patient receives 20 minutes of invasive mechanical ventilation with each of the three humidification systems in random sequence: * Heated and moisture exchanger (HME) * Heated humidifier (HH) * Hygrovent Gold
Primary Outcome Measures
NameTimeMethod
Change in muscle pressure-time product (PTPoes)Baseline and 60 minutes
Secondary Outcome Measures
NameTimeMethod

Trial Locations

Locations (1)

Fondazione Salvatore Maugeri

🇮🇹

Pavia, Italy