Study Overview

Brief Summary

This study compares the short-term effects of a new humidification system (Hygrovent Gold) and two other humidification devices (heated and moisture exchanger and heated humidifier) on respiratory pattern and work of breathing, during invasive ventilation.

Detailed Description

Three humidifying devices are commonly and indifferently used during mechanical ventilation, but their impact on respiratory mechanics and, eventually, mechanical ventilation efficacy, particularly in patients highly dependent from mechanical ventilation, are not superimposable.

It has already been described that heated and moisture exchangers (HME), increasing dead space, can negatively affect ventilatory function and gas exchange, in comparison to heated humidifiers (HH).

The Hygrovent Gold, mainly because of its position between the tracheostomy and the Y-piece of the ventilatory circuit and its structure, may lead to analogous or even worse effects, determining and increase in inspiratory resistances and dead space and consequently an increase in the work of breathing.

Study Design

Study Type
Interventional
Allocation
Na
Intervention Model
Single Group
Primary Purpose
Other
Masking
None

Eligibility Criteria

Ages
18 Years to — (Adult, Older Adult)
Sex
All
Accepts Healthy Volunteers
No

Inclusion Criteria

  • Chronic hypercapnic respiratory failure (PaCO2 of 45 mmHg or more)
  • Long-term mechanical ventilation via tracheostomy
  • Clinical stability

Exclusion Criteria

  • Non collaborative subjects
  • Acute respiratory failure
  • Haemodynamic instability
  • Encephalopathy

Outcomes

Primary Outcomes

Change in muscle pressure-time product (PTPoes)

Time Frame: Baseline and 60 minutes

Secondary Outcomes

No secondary outcomes reported

Investigators

Sponsor Class
Other
Responsible Party
Principal Investigator
Principal Investigator

Annia Schreiber

MD

Fondazione Salvatore Maugeri

Study Sites (2)

Loading locations...

Similar Trials

Completed
Not Applicable
Comparison of two types of airway humidifier in ventilated patients on pulmonary parameters and infection ratesMoisturizers act in a ventilator like an artificial nose. Oxygen, along with the volume produced, which is a dry gas, is heated and humidified by Humidifier, and is passed to the patient's lungs. Without proper moisturizing, it can damage the lungs and increase lung parameters and even infection (Ventilator Associated Pneumonia) causing Prolonging the process of separating patients from the device..
IRCT20171202037703N1Zanjan University of Medical Sciences80
Completed
Not Applicable
The impact of different humidification techniques in newly tracheotomized patients - an ex vivo studyZ93.0Tracheostomy status
DRKS00004865niversitätsklinikum Mannheim20
Completed
Not Applicable
To investigate the effect of the humidifying device in a driving simulator on driving performance and visual functio
JPRN-UMIN000015535Department of Ophthalmology, Keio University School of Medicine16
Completed
Not Applicable
High flow humidified nasal oxygen versus face mask oxygen for preoxygenation of pregnant women – a prospective randomised controlled crossover studyPregnancyPreoxygenationAnaesthesiology - AnaestheticsReproductive Health and Childbirth - Childbirth and postnatal careRespiratory - Normal development and function of the respiratory system
ACTRN12619000620123Department of Anaesthesia, The Royal Women's Hospital - Parkville70
Terminated
Not Applicable
Gases Humidification During Noninvasive Ventilation : Heat and Moisture Exchanger or Heated Humidifier ?PneumoniaAcute Heart FailureAcute Lung InjuryChronic Obstructive Pulmonary Disease
NCT00221819University Hospital, Bordeaux