SonoVue®-Enhanced Ultrasound Versus Unenhanced US for Focal Liver Lesion Characterization

Phase 3
Completed
Conditions
Liver Neoplasms
Interventions
Drug: SonoVue-enhanced ultrasound
Other: Unenhanced ultrasound
Registration Number
NCT00788697
Lead Sponsor
Bracco Diagnostics, Inc
Brief Summary

The purpose of this study is to demonstrate the superiority of SonoVue®-enhanced ultrasound versus unenhanced ultrasound for characterization of Focal Liver Lesions using final diagnosis based on histology or combined imaging/clinical data as truth standard.

Detailed Description

Unit of analysis for the outcome measures was the lesion, equivalent to the subject, since each subject had a single lesion that was to be characterized.

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
349
Inclusion Criteria
  • Male/female.
  • Provides written Informed Consent and is willing to comply with protocol requirements.
  • Is at least 18 years of age.
  • Has at least 1 focal liver lesion (FLL) (target lesion) requiring work-up for characterization. Target lesions may include those:
  • Incidentally detected,
  • In subjects with chronic hepatitis or liver cirrhosis,
  • In subjects with known history of malignancy.
  • Is scheduled for surgical removal or biopsy of the target lesion from 24 hours to 30 days after the SonoVue® administration OR
  • In case tissue biopsy is not indicated nor surgery planned, is scheduled for or has performed a contrast-enhanced (CE) CT and/or CE-MRI of the target lesion from 30 days to 48 hours prior to or from 24 hours to 30 days after the administration of SonoVue®.
Exclusion Criteria
  • Has an acoustic window insufficient for adequate ultrasound examination of the liver.

  • Has a FLL that cannot be identified with unenhanced ultrasound.

  • Has received or is scheduled for antineoplastic chemotherapy or an invasive procedure in the time period between test procedures and truth standard assessments which may have modified the target lesion.

  • Is receiving any other contrast medium, within the 48 hours before and up to 24 hours following the administration of SonoVue®.

  • Has previously been enrolled in and completed this study.

  • Known right to left cardiac shunt, bidirectional or transient.

  • Has any known allergy to 1 or more of the ingredients of the investigational product (sulfur hexafluoride or to any components of SonoVue®).

  • Has any contraindication to 1 of the planned imaging procedures (ultrasound, CT or MRI), e.g., implants, claustrophobia, inadequate medical conditions etc.

  • Has received an investigational compound within 30 days before admission into this study.

  • Has any medical condition or other circumstances which would significantly decrease the chances of obtaining reliable data, achieving study objectives, or completing the study and/or post-dose follow-up examinations.

  • Is determined by the Investigator that the subject is clinically unsuitable for the study.

  • Is a pregnant or lactating female. Exclude the possibility of pregnancy by:

    • testing on site at the institution serum beta-human chorionic gonadotropin (βHCG) within 24 hours prior to the start of SonoVue® administration,
    • surgical history (e.g., tubal ligation or hysterectomy),
    • post menopausal with a minimum 1 year without menses.

Study & Design

Study Type
INTERVENTIONAL
Study Design
SINGLE_GROUP
Arm && Interventions
GroupInterventionDescription
Patients who received SonoVueSonoVue-enhanced ultrasoundPatients with at least 1 target lesion requiring work-up for characterization to undergo * Unenhanced ultrasound of the target lesion (UE-US): gray scale and Doppler (color or power imaging) ultrasound investigations of the target lesion using commercially available ultrasound equipment and standard techniques (B-mode or Harmonic imaging) to study the anatomy of the target lesion and surrounding parenchyma; * SonoVue-enhanced ultrasound of the target lesion (CE-US): procedures described in protocol Section 7.5.1.2, to study the lesion vascularity in comparison to the surrounding parenchyma; and * Truth standard
Patients who received SonoVueUnenhanced ultrasoundPatients with at least 1 target lesion requiring work-up for characterization to undergo * Unenhanced ultrasound of the target lesion (UE-US): gray scale and Doppler (color or power imaging) ultrasound investigations of the target lesion using commercially available ultrasound equipment and standard techniques (B-mode or Harmonic imaging) to study the anatomy of the target lesion and surrounding parenchyma; * SonoVue-enhanced ultrasound of the target lesion (CE-US): procedures described in protocol Section 7.5.1.2, to study the lesion vascularity in comparison to the surrounding parenchyma; and * Truth standard
Primary Outcome Measures
NameTimeMethod
Sensitivity: Percentage of True Positive Lesions Among All Malignant Lesions Per Truth Standard24 hours to 6 months

Sensitivity of SonoVue-enhanced ultrasound (SonoVue CE-US) versus unenhanced ultrasound (UE-US) for characterization of malignant focal liver lesions (FLLs), using the diagnosis provided by each of the 3 off-site assessors (blinded to patient data) for the Intent-to-Diagnose (ITD) population. Unit of analysis was the lesion, equivalent to the subject, since each subject had a single lesion that was to be characterized.

True positive: subject with a target lesion characterized as malignant by both ultrasonography and the truth standard.

Truth standard: contrast-enhanced computed tomography (CE CT) and /or contrast-enhanced magnetic resonance imaging (CE-MRI) examination OR tissue pathology/histology from surgical resection/biopsy OR 6-month follow up. Calculated as (number of true positive lesions/number of malignant lesions per truth standard) x 100.

Specificity: Percentage of True Negative Lesions Among All Malignant Lesions Per Truth Standard24 hours to 6 months

Specificity of SonoVue-enhanced versus unenhanced ultrasound for characterization of benign FLLs, using the diagnosis provided by each of the 3 off-site assessors (blinded to patient data) for the ITD population. Unit of analysis was the lesion, equivalent to the subject, since each subject had a single lesion that was to be characterized.

True negative: subject with a target lesion characterized as benign by both ultrasonography and the truth standard.

Truth standard: CE-CT and /or CE-MRI examination OR tissue pathology/histology from surgical resection/biopsy OR 6-month follow up. Calculated as (number of true negative lesions/number of benign lesions per truth standard) x 100.

Secondary Outcome Measures
NameTimeMethod
Negative Predictive Value (NPV): Percentage of True Negative Lesions Among All Malignant Lesions Per Ultrasound24 hours to 6 months

Negative Predictive Value of SonoVue-enhanced versus unenhanced ultrasound for characterization of FLLs, using the diagnosis provided by each of the 3 off-site assessors (blinded to patient data) for the ITD population. Unit of analysis was the lesion, equivalent to the subject, since each subject had a single lesion that was to be characterized.

True negative: subject with a target lesion characterized as benign by both ultrasonography and the truth standard.

Truth standard: CE-CT and /or CE-MRI examination OR tissue pathology/histology from surgical resection/biopsy OR 6-month follow up. Calculated as (number of true negative lesions/number of benign lesions per ultrasound) x 100.

Positive Predictive Value (PPV): Percentage of True Positive Lesions Among All Malignant Lesions Per Ultrasound24 hours to 6 months

Positive Predictive Value of SonoVue-enhanced versus unenhanced ultrasound for characterization of FLLs, using the diagnosis provided by each of the 3 off-site assessors (blinded to patient data) for the ITD population. Unit of analysis was the lesion, equivalent to the subject, since each subject had a single lesion that was to be characterized.

True positive: subject with a target lesion characterized as malignant by both ultrasonography and the truth standard.

Truth standard: CE-CT and /or CE-MRI examination OR tissue pathology/histology from surgical resection/biopsy OR 6-month follow up. Calculated as (number of true positive lesions/number of malignant lesions per ultrasound) x 100.

Inter-reader Agreement24 hours to 6 months

Inter-reader agreement of assessment of malignant or benign by unenhanced and SonoVue-enhanced ultrasonography separately. Unit of analysis was the lesion, equivalent to the subject, since each subject had a single lesion that was to be characterized. Computation for the percentage agreement within two categories: "3 out of 3 readers agree" and "2 out of 3 readers agree".

Specific Diagnosis of Benign FLLs24 hours to 6 months

SonoVue-enhanced versus unenhanced ultrasound for specific diagnosis of benign FLLs, using the diagnosis provided by each of the 3 off-site assessors (blinded to patient data) for the ITD population. Unit of analysis was the lesion, equivalent to the subject, since each subject had a single lesion that was to be characterized.

Truth standard: CE-CT and /or CE-MRI examination OR tissue pathology/histology from surgical resection/biopsy OR 6-month follow up. Calculated as (number of correctly characterized lesions/number of lesions per truth standard) x 100.

Accuracy: Percentage of True Positive and True Negative Among All Lesions24 hours to 6 months

The Accuracy of SonoVue-enhanced versus unenhanced ultrasound for characterization of malignant and benign FLLs, using the diagnosis provided by each of the 3 off-site assessors (blinded to patient data) for the ITD population Unit of analysis was the lesion, equivalent to the subject, since each subject had a single lesion that was to be characterized.

True positive: subject with a target lesion characterized as malignant by both ultrasonography and the truth standard.

True negative: subject with a target lesion characterized as benign by both ultrasonography and the truth standard.

Truth standard: CE-CT and /or CE-MRI examination OR tissue pathology/histology from surgical resection/biopsy OR 6-month follow up. Calculated as (number of true positive and true negative lesions/number of total lesions per truth standard) x 100.

Specific Diagnosis of Malignant FLLs24 hours to 6 months

SonoVue-enhanced versus unenhanced ultrasound for specific diagnosis of malignant FLLs, using the diagnosis provided by each of the 3 off-site assessors (blinded to patient data) for the ITD population. Unit of analysis was the lesion, equivalent to the subject, since each subject had a single lesion that was to be characterized.

Truth standard: CE-CT and /or CE-MRI examination OR tissue pathology/histology from surgical resection/biopsy OR 6-month follow up. Calculated as (number of correctly characterized lesions/number of lesions per truth standard) x 100.

Trial Locations

Locations (1)

Bracco Diagnostics Inc

🇺🇸

Princeton, New Jersey, United States