跳至主要内容
临床试验/NCT01097434
NCT01097434已完成4 期

Randomized Comparison of Limus-Eluting Stents With Biodegradable or Permanent Polymer Coating Regarding Stent Coverage Assessed by Optical Coherence Tomography

Deutsches Herzzentrum Muenchen2 个研究点 分布在 1 个国家目标入组 48 人开始时间: 2010年4月1日最近更新:
适应症

试验速览

阶段
4 期
状态
已完成
发起方
入组人数
48
试验地点
2
主要终点
Percentage of uncovered stent strut segments assessed by OCT

研究概览

简要总结

The objective of the study is to assess the superiority of the biodegradable polymer based limus-eluting stent (Nobori®) compared with the permanent polymer based everolimus-eluting stent (XIENCE V®) regarding absolute percentage of uncovered stent strut segments.

详细描述

The mid-term efficacy of drug-eluting stents has been well-established, but there is an ongoing debate on the potential of an increased incidence of late stent thrombosis, particularly after discontinuation of thienopyridine therapy, as well as of delayed onset of restenosis or catch-up phenomenon with permanent polymer-based DES. The extent of strut coverage with reduction of exposed thrombogenic material has been shown to be associated with the inflammatory reaction grade and with the incidence of stent thrombosis. The optical coherence tomography (OCT) is an intravascular imaging modality based on light. The principle is similar to intravascular ultrasound, but due to the much shorter wave length of light, it offers a much better resolution up to 10µm, enabling the exact determination of strut coverage, neointimal thickness, vessel size, presence of dissections, and even the presence of inflammation.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patients older than age 18 with ischemic symptoms or evidence of myocardial ischemia in the presence of ≥ 50% stenosis located in native coronary vessels
  • Written, informed consent by the patient or her/his legally-authorized representative for participation in the study
  • In women with childbearing potential a negative pregnancy test is mandatory

排除标准

  • Lesion length >16mm requiring a stent length >18mm
  • Target lesion located in the left main trunk
  • In-stent restenosis
  • Acute myocardial infarction
  • Malignancies or other comorbid conditions (for example severe liver, renal and pancreatic disease) with life expectancy less than 12 months or that may result in protocol non-compliance
  • Known allergy to the study medications: rapamycin, everolimus, biolimus, stainless steel or cobalt chrome
  • Inability to take dual antiplatelet therapy for at least 6 months
  • Pregnancy (present, suspected or planned) or positive pregnancy test
  • Previous enrollment in this trial
  • Patient's inability to fully cooperate with the study protocol

结局指标

主要结局

Percentage of uncovered stent strut segments assessed by OCT

时间窗: 6-8 months

次要结局

  • Percentage of malposed stent strut segments assessed by OCT(6-8 months)

研究者

发起方
Deutsches Herzzentrum Muenchen
申办方类型
Other
责任方
Sponsor

研究点 (2)

Loading locations...

相似试验