跳至主要内容
临床试验/NCT04389879
NCT04389879进行中(未招募)不适用

CAD/CAM Fixed Retainers vs. Conventional Multistranded Fixed Retainers in Orthodontic Patients. Comparison of Stability, Retainer Failure Rate, Adverse Effects, Cost-effectiveness, and Patient Satisfaction. A Randomized Controlled Clinical Trial.

University of Aarhus4 个研究点 分布在 2 个国家目标入组 126 人开始时间: 2018年9月1日最近更新:
适应症

试验速览

阶段
不适用
状态
进行中(未招募)
入组人数
126
试验地点
4
主要终点
Stability

研究概览

简要总结

Introduction:

Orthodontic retainers are used after the completion of orthodontic treatment to assure dental occlusal stability and to maintain the achieved end-result. However, without retention teeth could go back to their initial dental malposition or could even take a different unpredicted position resulting once again in dental malocclusion (a deviation from normal occlusion).

There are different types of retainers, some are fixed (glued to the back of the front teeth), and others are removable (can be removed and replaced into the mouth by the patient).

While there are various retainers used for retention (stability), there is no perfect method. Fixed retainers (FRs) are used worldwide. On the one hand, FRs focus on preventing relapse. On the other hand, there are sometimes some adverse effects of retainers; they could fail at a certain point (break/get loose), or cause unwanted tooth movements. Until now, the choice of a retention method is based solely on clinicians' experience as there is no substantial evidence regarding the best retention method or the duration of the retention period. Some clinicians prolong the retention period while others prefer to keep the retainers for an indefinite time.

As the world is advancing, so is the orthodontic science. New FR fabricated by CAD/CAM (Computer-Aided Design/Computer-Aided Manufacturing), are assumed to have greater accuracy, better fit, and most importantly, might offer a passive positioning of the retainer. However, the evidence about CAD/CAM FRs is very limited.

Purpose:

To investigate and compare the clinical effectiveness of two types of FRs; CAD/CAM vs. multistranded wire, in terms of stability (primary outcome), failure rate, adverse effects, cost-effectiveness, and patient satisfaction (secondary outcomes), substantial up to 5 years after retainer placement.

Hypotheses:

Compared to traditional multistranded FRs, CAD/CAM FRs have:

  • Better long term stability,
  • Similar failure rate,
  • Fewer adverse effects,
  • Similar cost-effectiveness and patient satisfaction.

详细描述

Material and Methods

Setting: Section of Orthodontics, Department of Dentistry and Oral Health, Aarhus University, Denmark and Department of Orthodontics, Faculty of Dentistry, University of Oslo, Norway.

Sample size: 126 participants are needed for this study.

Randomization: After oral and written consent is obtained, allocation to groups, either conventional multistranded Stainless Steel fixed retainers, or CAD/CAM custom-cut Nickel Titanium fixed retainers, will take place at the last appointment before debonding. Subjects will be allocated 1:1 into one of the two groups.

Intervention protocol: After completing a full active orthodontic treatment, at both centers. The achieved treatment end result has to be maintained in the long term in order to prevent relapse (movement of teeth to the initial malocclusion). One of either two different fixed retainers will be bonded (to the upper and lower anterior teeth) by one operator in each center.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Other
盲法
None

盲法说明

The outcome assessor will be blinded only to the patient satisfaction and cost-effectiveness outcomes.

入排标准

年龄范围
12 Years 至 25 Years(Child, Adult)
性别
All
接受健康志愿者

入选标准

  • Healthy patients.
  • Age: 12-25 years old (at time of debonding).
  • Presence of all maxillary and mandibular anterior teeth, with normal shape and size.
  • Completion of a course of fixed appliance therapy involving both dental arches.
  • Subjects willing to consent to the trial and comply with the trial regime.
  • No restriction to presenting initial malocclusion, type of active orthodontic treatment undertaken provided that it included full fixed appliances (functional/removable appliances in combination with fixed appliances - extraction or non-extraction)

排除标准

  • Patients with cleft lip or palate, or both or any other craniofacial syndrome.
  • Patients who had surgical correction of the jaws: Le fort I (2- or 3-piece maxilla) or SARPE (surgically assisted rapid palatal expansion).
  • Lingual appliance treatments.
  • Periodontal disease.
  • Hypoplasia of enamel.
  • Active caries, restorations or fractures in the anterior teeth.
  • Patients who have had separate debonding appointments for each jaw, with a difference of more than 2 months in between.
  • Re-treated patients.

结局指标

主要结局

Stability

时间窗: From debonding (T1), and after 6, 12, 24, 36 and 60 months in retention phase (T4, T5, T6, T7, and T8 respectively)

Change in lower incisor crowding will be assessed using Little's Irregularity Index (LII). Change in overall occlusal stability will be assessed by the Peer Assessment Rating (PAR) index. In addition, changes in arch dimensions, occlusal relationships, and re-opening of extraction spaces will be recorded.

次要结局

  • Adverse effects(From debonding, and up to 60 months later)
  • Failure rate and survival time(From the time of retainer bonding to the first failure episode: From debonding, and up to 60 months later)
  • Cost-effectiveness(From debonding, and up to 60 months later)
  • Patient satisfaction(From debonding, and after 1, 6 and 12 months in retention phase)

研究者

申办方类型
Other
责任方
Sponsor

研究点 (4)

Loading locations...

相似试验