Randomized Clinical Trial Assessing Laryngeal Mask Airway (LMA) Versus Face-mask Ventilation (FMV) in Neonatal Resuscitation at Mulago Hospital, Uganda
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- 入组人数
- 50
- 试验地点
- 1
- 主要终点
- time to spontaneous ventilation
研究概览
简要总结
The purpose of this study is to compare the use of a laryngeal mask airway (LMA) vs. face-mask ventilation (FMV) during first-line neonatal resuscitation in Mulago Hospital, Kampala, Uganda.
详细描述
Background: Perinatal mortality in Eastern Uganda 2007/2008 was estimated to 41/1000 pregnancies. The rate of stillbirth was 19/1000. In the whole of Uganda in 2008, neonatal deaths constituted 21% of an estimated 190,000 under five deaths, while HIV constituted only 5%. Implementing a Helping Babies Breathe (HBB) program in one centre in Tanzania resulted in almost 40 % reduction of early neonatal mortality. Introducing a neonatal intervention package even reduced the rate of stillbirths. Birth asphyxia (BA) accounted for 60% of early neonatal deaths in Haydom Lutheran Hospital, Tanzania.
The need for resuscitation is greater in the neonate than in any other age group. Providing effective positive pressure ventilation (PPV) is the single most important component of successful neonatal resuscitation (5). Ventilation is frequently initiated with face-mask ventilation (FMV) followed by endotracheal intubation (ETT) if depression continues. These techniques may be difficult to perform resulting in prolonged resuscitation. The laryngeal mask airway (LMA) may achieve initial ventilation and successful resuscitation faster than a face-mask device or ETT. Various publications and a Cochrane review has shown LMA to be as efficient as ETT. Important air leakage during FMV is an issue. LMA reduces the need for ETT. The latest generation of LMA is made of a medical-grade gel-like elastomer designed to provide an efficient seal to the larynx without an inflatable cuff. The risk for trauma is minimised. Insertion is easy with a low risk of tissue compression or dislodgement. In a study to evaluate educational intervention in the Democratic Republic of Congo, both physicians and midwifes showed a good level of expertise in LMA insertion on mannequins. Both groups almost unanimously manifested a high degree of approval of neonatal resuscitation with LMA.
Objective: To compare the use of uncuffed LMA vs. FMV during neonatal resuscitation in Mulago Hospital, Kampala, Uganda.
Study design, setting and population: A randomized clinical trial will be conducted in Mulago hospital among asphyxiated neonates in the delivery unit. Approximately 33000 babies are born in this hospital each year.
Prior to the intervention all staff in the labour ward performing resuscitation will receive training according to the HBB curriculum with a special module for training on LMA insertion.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Parallel
- 主要目的
- Treatment
- 盲法
- None
入排标准
- 年龄范围
- — 至 1 Hour(Child)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •estimated gestation > 34 weeks
- •estimated weight > 2000 gram
- •need for Positive Pressure Ventilation (PPV) at birth
排除标准
- •still birth
- •major malformations
- •severe prenatal depression (Heart rate <60 1 minute after birth)
结局指标
主要结局
time to spontaneous ventilation
时间窗: one day
To assess if the ventilation time needed for neonates with an estimated birth weight of 2 kg or above and in need of initial respiratory support can be decreased from an average of 132 seconds in infants being resuscitated using FMV (control arm) to an average ventilation time of 72 seconds for infants resuscitated with the use of LMA (interventions arm).
次要结局
- proportion of infants who require advanced resuscitation(1 day)
- the proportion of infants with adverse birth outcome(2 days)