Permanent Conduction System Pacing Versus Atrioventricular Management for Patients With Wide QRS and Patent AV Conduction
试验速览
- 阶段
- 不适用
- 状态
- 招募中
- 发起方
- 入组人数
- 120
- 试验地点
- 3
研究概览
简要总结
Intraventricular conduction delay alone or in combination with AV conduction delay is associated with a dyssynchronous activation of the ventricles and may result in LV function impairment.
Conduction system pacing can restore physiologic ventricular activation in the presence of intraventricular and atrioventricular conduction delays.
Patients with intraventricular conduction delay alone or in combination with AV conduction delay who have a permanent pacemaker indication due to intermittent bradycardia and have predominantly intact AV conduction may benefit from continuous CSP.
详细描述
Study design: Multicenter, prospective, randomized, cross-over, patient-blinded study
Study Objectives:
- Primary objective: The primary objective of the study is to demonstrate that CSP is associated with better LVEF and GLS preservation at 12-month follow-up in comparison to native conduction with wide QRS. The percentages of patients with a ≥10% decline in LVEF and or ≥ 15% decline in GLS between groups will be considered for the primary outcome.
- Principal secondary objectives: NYHA class at 12 months, Walking distance in 6 minutes walking test, Quality of life (EQ EQ 5D), To evaluate reverse ventricular remodeling response and dyssynchrony parameters based on echocardiographic data at 12 months follow-up, To evaluate device battery longevity estimation at 12-month follow-up, To evaluate HF related hospitalizations/ER visits at 12 months follow-up, To evaluate mortality (global and cardiovascular) at 12-month follow-up, To evaluate incidence of ventricular arrhythmias at 12-month follow-up, To evaluate differences in LVEF and remodeling parameters depending on the final CSP modality (LBBP vs LVSP), To evaluate device related complications at 12-month follow-up, To evaluate differences between pacing indication groups (acute LBBB vs unknown/chronic wide QRS)and To evaluate percentage of patients randomized to continuous pacing who loose AV conduction after 12 months of continuous pacing Primary Endpoint: LVEF decrease ≥ 10% and/or GLS decrease ≥ 15% at 12-month follow-up with respect to baseline value
Study population criteria
- Inclusion criteria: age > 18 years, Any indication for cardiac pacing with an expected VP burden ≤ 10% after 1-month run-in period, Baseline wide QRS (≥150 ms) with normal PR or QRS ≥ 130 ms + PR≥230 ms, Confirmed CSP criteria (LBBAP including LBBP and LVSP), LVEF≥50% and Signed and dated informed consent.
- Exclusion criteria: Pregnant woman, Age < 18 years, Permanent or long-lasting atrial fibrillation, Previous PM/ICD, Unstable angina, acute Myocardial Infarction (MI), Coronary Artery Bypass Graft (CABG), Percutaneous Coronary Angioplasty (PCI), valve repair or replacement within 90 days prior enrollment, Moderate-severe valvular heart disease (not repaired), Already included in another clinical study that could confound the results of the present study, Infiltrative disease or any other genetically or acquired primary myocardial disease, Life expectancy < 2 years and LVEF <50%
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Crossover
- 主要目的
- Supportive Care
- 盲法
- Single (Participant)
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •age > 18 years
- •Any indication for cardiac pacing with an expected VP burden ≤ 10% after 1- month run-in period
- •Baseline wide QRS (≥150 ms) with normal PR or QRS ≥ 130 ms + PR≥230 ms
- •Confirmed CSP criteria
- •Signed and dated informed consent
排除标准
- •Pregnant woman
- •Permanent or long-lasting atrial fibrillation
- •Previous PM/ICD
- •Unstable angina, acute Myocardial Infarction (MI), Coronary Artery Bypass Graft (CABG), Percutaneous Coronary Angioplasty (PCI), surgical valve repair or replacement within 90 days prior enrollment
- •Moderate-severe valvular heart disease (unrepaired)
- •Already included in another clinical study that could confound the results of the present study
- •Infiltrative disease or any other genetically or acquired primary myocardial disease
- •Life expectancy < 2 years
- •LVEF <50%
研究组 & 干预措施
CSP ON
Continuous Conduction System Pacing (CSP)
干预措施: Pacemaker implant (Device)
CSP OFF
Non active Conduction System Pacing (CSP)
干预措施: Pacemaker implant (Device)
研究者
Óscar Cano Pérez
Principal Investigator
Spanish Society of Cardiology
