跳至主要内容
临床试验/CTRI/2020/04/024599
CTRI/2020/04/024599尚未招募不适用

Comparison of the 10-2 full threshold, 10-2 ZEST, 10-2 fast algorithm Elisar AVATM with corresponding algorithm of 10-2 of Humphrey visual field analyzer

Dr Amar Agarwal1 个研究点 分布在 1 个国家目标入组 165 人开始时间: 2020年4月20日最近更新:
适应症

试验速览

阶段
不适用
状态
尚未招募
发起方
入组人数
165
试验地点
1
主要终点
To establish the equivalence between threshold estimates of 10-2 Elisar AVA with the 10-2 of Humphrey visual field analyser

研究概览

简要总结

Purpose: The study aims to prove the equivalence of threshold estimates of 10-2 full threshold algorithm, 10-2 Elisar ZEST and 10-2 Elisar fast of AVATM with the corresponding algorithm of an established, industry-recognized visual field analyzer (Zeiss Humphrey Field Analyzer, or HFA).

Description of the study: Cross-sectional study to compare thethreshold estimates of 10-2 full threshold algorithm, 10-2 Elisar ZEST the algorithm, 10-2 Elisar fast algorithm of AVATM with thecorresponding algorithm of Zeiss Humphrey visual field analyzer (HFA)in both a the healthy control group and a study group exhibiting field loss (secondary toglaucoma or non-glaucoma conditions).

Study duration: 45 days

Study design: A cross-sectional study.

Inclusion criteria: Best-corrected visual acuity better than 6/12; Cup disc ratio less than 0.5 for controls.

Best-corrected visual acuity better than 6/12; cup disc ratio more than 0.5 for glaucoma.

Exclusion criteria: Patients who are under miotic therapy will be excluded from the study.

Methodology: The control group will undergo dilationfollowed by random execution of both 10-2 full threshold of AVATM and10-2 full threshold of HFA trial procedures. The glaucoma group and the other conditions group will undergogonioscopy and applanation tonometry; patients with open angles will be dilatedprior to random execution of AVATM and HFA trial procedures. ForPatients with closed angles the trial will be done with undilated pupils.

Analysis: ICC and Bland Altman plots will be made to compare the threshold estimates of 10-2 of Elisar AVATM and the 10-2 of Humphrey visual field analyzer

研究设计

研究类型
Observational

入排标准

年龄范围
17.00 Year(s) 至 70.00 Year(s)(—)
性别
All

入选标准

  • •Controls:
  • •Cup disc ratio of less than 0.
  • •IOP less than 20 mm Hg
  • •Visual acuity better than 6/12.

排除标准

  • •Patients who had undergone ocular surgeries (other than cataract surgery), patients with ocular disease, amblyopia, neurological disorders will be excluded from the study.
  • •Patients using a miotic drug will be excluded from the study.

结局指标

主要结局

To establish the equivalence between threshold estimates of 10-2 Elisar AVA with the 10-2 of Humphrey visual field analyser

时间窗: 45 days

次要结局

  • To establish the equivalence in mean deviation and pattern standard deviation between threshold estimates of 10-2 Elisar AVA with the 10-2 of Humphrey visual field analyser(45 days)

研究者

发起方
Dr Amar Agarwal
申办方类型
Other [self]

研究点 (1)

Loading locations...