A Pilot Study to Evaluate A Noninvasive Multimodal Biosensing Device for Screening and Monitoring Response to Treatment of Infectious Respiratory Diseases

Eunice Kennedy Shriver National Institute of Child Health and Human Development (NICHD)2 个研究点 分布在 1 个国家目标入组 40 人开始时间: 2022年5月26日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
40
试验地点
2
主要终点
Compare performance of a multimodal biosensor device with commercial systems for measuring vital physiological signals including cardiac, respiratory, and tissue oxygenation in individuals at rest.

研究概览

简要总结

Background:

The COVID-19 outbreak has strained the health care system. New tools are needed for diagnostic testing and monitoring of people who have the virus. Researchers want to test a device they hope can screen, detect, and monitor symptoms linked to respiratory diseases like COVID-19.

Objective:

To evaluate and validate a device that measures breathing, body temperature, heart rate, and tissue oxygenation.

Eligibility:

Healthy adults ages 18 and older with no flu-like symptoms and no current signs of infection, cough, fever, or sneezing.

Design:

Participants will have a physical exam. Their vital signs will be taken.

Participants will sit in a chair. They will be monitored for 60 to 80 minutes while they do the following tasks:

Rest for 10 minutes. They will repeat this after each task.

Hold their breath for up to 2 minutes and then rest for 2 minutes. They will do this task 3 times.

Pace-breathe with breathing rates of 10, 20, and 30 breaths per minute. They will do this task 2 times.

Breathe air that has 5% of carbon dioxide for 5 minutes.

During these tasks, data will be collected and recorded with a pulse oximeter, thermometer, respiratory belt, and spirometer.

Participants will fill out questionnaires related to their daily activity (medication intake, exercise, smoking, and drinking).

Participation will last for 2 to 3 hours.

详细描述

Study Description:<TAB>

This observational pilot study will characterize the performance of a multimodal biosensor device (a portable and a wireless NIRS device, PPG and temperature sensor) in measuring human vital signs, which later will be explored as a point-of-care method for screening and treatment response monitoring of individuals with an infectious respiratory illness. The devices will measure heart, respiratory, and tissue oxygenation parameters in healthy subjects at rest and during induced hypercapnia, breath holding, and paced breathing.

Objectives:

<TAB>

Primary objective: Compare performance of two multimodal NIRS biosensor devices with commercial systems for measuring vital physiological signals including cardiac, respiratory, and tissue oxygenation in individuals at rest.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Device Feasibility
盲法
None

入排标准

年龄范围
18 Years 至 78 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • INCLUSION CRITERIA:
  • In order to be eligible to participate in this study, an individual must meet all of the following criteria:
  • Provision of signed and dated informed consent form.
  • Stated willingness to comply with all study procedures and availability for the duration of the study.
  • Male or female aged 18 years or greater.
  • In good general health as evidenced by medical history with no signs of cough, sneeze and upper respiratory symptoms.
  • Body temperature in normal range (afebrile, temperature < 100.4 (Infinite) F) on the day of the experiment.

排除标准

  • Any skin disease.
  • Fever (Temperature greater than or equal to 100.4 degrees F).
  • Any past or present cardiovascular or pulmonary diseases.
  • Known adverse reaction to latex.
  • Any medical condition that, in the opinion of the Principal Investigator would preclude the inclusion of a patient onto this research study.
  • Unable or unwilling to give informed consent.
  • Individuals with known respiratory conditions.
  • Individuals who are currently taking medication that may cause methemoglobinemia such as nitrates derivatives, sulfonamides, dapsone, phenacetin, phenazopyridine, some local anesthetics such as prilocaine, topical anesthetics such as emla cream, benzocaine.
  • Individuals with history of seizure.
  • Smokers and those on narcotics.
  • Pregnant women are excluded due to risk associated to hypercapnia risk

结局指标

主要结局

Compare performance of a multimodal biosensor device with commercial systems for measuring vital physiological signals including cardiac, respiratory, and tissue oxygenation in individuals at rest.

时间窗: End of study

Compare performance of two multimodal NIRS biosensor devices with commercial systems for measuring vital physiological signals including cardiac, respiratory, and tissue oxygenation in individuals at rest.

次要结局

  • Compare measured changes in cardiac, respiratory, and tissue oxygenation parameters during induced hypercapnia, breath holding, and paced breathing exercises between the biosensor and commercial systems.(End of study)
  • Characterize arterial oxygen saturation (SpO2), peripheral oxygen saturation (StO2) and cerebral oxygen saturation (ScO2) during respiratory perturbations.(End of study)