Early Discovery of Ischemia After Replantation Surgery of the Extremities (EDIR-study) ; An Open, Prospective, Intervention Study

Oslo University Hospital1 个研究点 分布在 1 个国家目标入组 60 人开始时间: 2022年11月15日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
进行中(未招募)
发起方
入组人数
60
试验地点
1
主要终点
Tissue CO2-level

研究概览

简要总结

Investigators will test if changes in CO2 is detected postoperatively in ischemic tissue in a replanted extremity of a traumatically amputated upper or lower extremity. IscAlert is measuring continuously CO2 in muscular and subcutaneous tissue. IscAlert is inserted distal to the operative field into normal muscle and/or subcutaneous tissue in the replanted extremity. Local tissue CO2 and temperature will be monitored continuously postoperatively for the next 10 days. If a reduced or totally obstructed blood flow appear (thrombosis), an increase in tissue CO2 and a lower local temperature will emerge rapidly as a sign of ischemia. This will be detected by the sensor which will alarm the investigators. This will lead to assessment of the replanted extremity and if restricted blood flow is diagnosed, a reoperation will be performed. After reoperation new sensors will be implanted for another ten days if applicable. Sixty patients will be enrolled to undergo the procedures. The IscAlert will be removed from the patient before the patient is discharged from the hospital or a maximum of 10 days (the event that occurs first). 500 devices is planned to be used in this clinical study.

详细描述

This is an open, prospective, interventional, single-center clinical investigation designed to examine the feasibility and safety of the IscAlert™ device in patients scheduled for extremity replant surgery. Sixty patients will be enrolled to undergo the procedures using a total of 400 devices depending on the injuries.

IscAlert is 0.8 mm in diameter and in vitro testing, shows stable and accurate measurements of pCO2. More than 200 animal experiments have been done with the sensor. The experiments have shown that the sensor detects ischemia (Increased CO2-measurements) in real time in the following organs and tissues: Brain, heart, liver, kidneys, pancreas, intestines, musculature and subcutaneous tissue. Sensitivity and specificity are close to 100%. The sensors are inserted into tissue by a split needle technique. The split needle is the size of a 3-gauge peripheral venous catheter. In animal studies, no complications have been detected when using the sensor.

The IscAlert catheters are connected to an electronics unit that is fixed to the skin with an adhesive plaster or glue outside the sterile area. The electrical signals are redirected to a PC approved for clinical use which continuously records tissue pressures of CO2.

IscAlert is inserted into normal muscle and/or subcutaneous tissue distal on the replanted limb to be operated at the end of surgery or immediate postoperatively. The insertion is far away from the operating field. The insertion is done under sterile conditions in accordance with standard sterility criteria at the hospital. No pain during insertion will occur because of insertion is performed during anesthesia (general or regional). Also, the insertion can be compared to an intramuscular injection.

Postoperatively, the IscAlert sensor will continuously monitoring tissue CO2 and temperature. If ischemia occur, for examples caused by a thrombus, an increase in tissue CO2 and a lower temperature will evolve. This will be detected by the sensor which will alarm the investigators. This will lead to assessment of the replanted extremity and if restricted blood flow is diagnosed or suspected, a reoperation will be performed.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Diagnostic
盲法
None

入排标准

年龄范围
18 Years 至 100 Years(Adult, Older Adult)
性别
All
接受健康志愿者
否

入选标准

  • •Patients must be in need of extremity replantation surgery
  • •Subject must be ≥ 18 years
  • •Able to give written signed informed consent

排除标准

  • 未提供

研究组 & 干预措施

Patients with replanted extremity monitored by tissue CO2

Experimental

Patients with traumatic amputation of a limb who are undergoing replantation surgery and are monitored postoperatively with IscAlert biosensor measuring local tissue CO2 and temperature in the replanted extremity

干预措施: IscAlert (Device)

结局指标

主要结局

Tissue CO2-level

时间窗: 10 days

Tissue CO2-level (kPa) during insertion period

次要结局

  • Bleeding(10 days)
  • Infection(30 days)
  • Length of stay at hospital(30 days)
  • Time to reduced blood flow in replanted extremity(10 days)
  • Number of re-operations(30 days)

研究者

发起方
Oslo University Hospital
申办方类型
Other
责任方
Principal Investigator
主要研究者

Magne Røkkum

Professor

Oslo University Hospital

研究点 (1)

Loading locations...

相似试验