Safer Sleep: A Diagnostic Accuracy Study Evaluating Breath Sound Recordings and STOP-Bang In Screening For Obstructive Sleep Apnea While Awake
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 439
- 试验地点
- 1
- 主要终点
- Screening and diagnostic test performance of Awake-OSA and STOP-Bang
研究概览
简要总结
The investigators will perform a diagnostic accuracy study comparing tracheal breath sound recordings in awake individuals to the STOP-Bang screening questionnaire, using the apnea-hypopnea index (AHI) score determined by polysomnography as the gold standard.
详细描述
Obstructive sleep apnea (OSA) is a breathing disorder with numerous health effects including a greater risk of peri-operative anesthetic complications. Numerous screening tools exist but are not without limitations. Diagnostic overnight sleep studies are resource-intensive and difficult to obtain in the short time period between pre-operative clinic assessment and the day of surgery.
This project aims to test the diagnostic performance of a new screening technology, Awake-OSA, for screening of obstructive sleep apnea (OSA). "Awake-OSA" uses a small external microphone placed on the neck, to record and analyze tracheal breath sounds at the bedside while the patient is awake.
Using polysomnography (PSG) as a gold standard, the investigators will compare Awake-OSA (breath sound recording) and the STOP-Bang screening questionnaire in their ability to accurately identify patients with OSA, as well as classify OSA in terms of severity.
Early, point-of-care diagnosis has the potential to provide a low-cost, convenient alternative to traditional screening questionnaires and enable more selective use of PSG. Our goal is to improve peri-operative patient safety while improving use of resources and streamlining patient care.
研究设计
- 研究类型
- Observational
- 观察模型
- Cohort
- 时间视角
- Prospective
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •18 years and older.
- •Referred for diagnostic sleep study.
- •Willing and able to consent.
排除标准
- •Under the age of 18 yrs.
- •Unwilling or unable to give consent.
- •Expected to have an abnormal EEG (epilepsy, brain tumour, deep brain stimulator).
- •Significant craniofacial abnormality (ex. unrepaired cleft lip/palate).
结局指标
主要结局
Screening and diagnostic test performance of Awake-OSA and STOP-Bang
时间窗: Night 1
Screening and diagnostic test performance of Awake-OSA and STOPBang in identifying OSA vs non-OSA patients, using AHI as gold-standard reference.
次要结局
- Development of new diagnostic algorithm determined by predictive values, sensibility, and specificity(Through study completion, average two years)