Skip to main content
Clinical Trials/NCT00842231
NCT00842231
Completed
Not Applicable

Assessment of Visual Performance in Patients With Low Levels of Astigmatism

Alcon Research1 site in 1 country40 target enrollmentJanuary 2009

Overview

Phase
Not Applicable
Intervention
Not specified
Conditions
Cataract Extraction
Sponsor
Alcon Research
Enrollment
40
Locations
1
Primary Endpoint
High and Low Contrast Acuity
Status
Completed
Last Updated
15 years ago

Overview

Brief Summary

To assess visual performance in patients with low levels (0.5-0.75 Diopters) of corneal astigmatism.

Registry
clinicaltrials.gov
Start Date
January 2009
End Date
March 2009
Last Updated
15 years ago
Study Type
Observational
Sex
All

Investigators

Eligibility Criteria

Inclusion Criteria

  • 50-75 years of age
  • Proof of eye exam within the last 12 months
  • Operated for uncomplicated, age-related cataracts \>3 months
  • Corneal astigmatism of 0.5-0.75 diopter

Exclusion Criteria

  • Previous ocular or refractive surgery/trauma
  • Clinically severe corneal dystrophy
  • Amblyopia
  • Degenerative visual disorders

Outcomes

Primary Outcomes

High and Low Contrast Acuity

Time Frame: Day of study visit

Visual acuity differences between subjects tested with full correction and spherical equivalent (SE) correction at contrast levels of 9% and 25% (low contrast acuity) and 100% (high contrast acuity). LogMAR is the "logarithm of the minimum angle of resolution". A lower logMAR value indicates better VA. These measurements were performed under photopic conditions by means of 9%, 25%, and 100% contrast ETDRS (Early Treatment Diabetic Retinopathy Study) charts (Vector Vision).

Contrast Sensitivity

Time Frame: Day of Study Visit

Contrast Sensitivity (CS) differences between subjects tested with full correction \& spherical equivalent (SE) correction. CS is the measurement of one's ability to detect slight changes in luminance before it becomes indistinguishable. CS is measured in logarithmic units by means of an illuminated box, the CSV 1000 by Vector Vision. Testing was performed under photopic conditions (no glare) \& mesopic conditions (with \& without glare), and was measured at four spatial frequencies of 3, 6, 9, and 12 cycles per degree (cpd). A higher value for the logarithmic units translates to better CS.

Reading Acuity and Speed

Time Frame: Day of Study Visit

Reading Acuity and Speed differences between subjects tested with full correction and spherical equivalent (SE) correction. Reading Acuity was measured using the Radner reading charts, which are logarithmically scaled at different acuity levels (print sizes), and expressed in terms of logRAD (logrithmic Reading Acuity Determination). Reading speed was measured in words per minute (wpm). The results were presented as Average Reading Speed by Print Size (logRAD).

Study Sites (1)

Loading locations...

Similar Trials