The Use of CO2 Automated Angiographies Combined With Fusion Imaging to Obtain Zero- or Near Zero- Contrast FEVAR for Complex Aortic Aneurysms.
试验速览
- 阶段
- 不适用
- 状态
- 招募中
- 发起方
- 入组人数
- 40
- 试验地点
- 1
- 主要终点
- Number of participants with perioperative renal function worsening
研究概览
简要总结
Fenestrated endovascular aneurysm repair (FEVAR) is an established technique used to treat complex aortic aneurysms (TAAAs), with satisfactory early and midterm results.
Postoperative renal function worsening is a common adverse event after FEVAR of complex aneurysms and is associated with prolonged hospital stay, higher morbidity, and long-term mortality in the peri-operative period and during follow-up. One of the more common causes of renal function worsening is contrast-induced nephropathy resulting from the use of iodinated contrast medium (ICM).
Automated carbon dioxide (CO2) angiography has been proposed as an alternative to ICM for standard endovascular aneurysm repair (EVAR) in consideration of its absence of nephrotoxicity that can be of further help in preserving renal function.
In adjunct, hybrid room and fusion imaging (FI) technologies are useful tools to reduce intraoperative contrast medium and fluoroscopy time.
In literature there are few reports regarding the use of CO2 for fenestrated endografting repair of complex aortic aneurysms.
The aim of the present study is to report the possibility to combine the use of automated CO2 angiographies and Fusion Imaging to obtain zero- or near zero- contrast FEVAR for complex aortic aneurysms.
详细描述
Fenestrated endovascular aneurysm repair (FEVAR) is an established technique used to treat juxtarenal and pararenal abdominal aortic aneurysms (AAAs) and type IV thoracoabdominal aortic aneurysms (TAAAs), as demonstrated by early and midterm literature results.
Postoperative renal function worsening is a common adverse event after FEVAR of complex aneurysms and is associated with prolonged hospital stay, higher morbidity, and long-term mortality in the peri-operative period and during follow-up.
Renal function may worsen after FEVAR because of a variety of factors, but one of the more common causes of renal function worsening is contrast-induced nephropathy resulting from the use of iodinated contrast medium (ICM).
Automated CO2 angiography has been proposed as an alternative to ICM for standard endovascular aneurysm repair (EVAR) in consideration of its absence of nephrotoxicity that can be of further help in preserving renal function.
In adjunct, hybrid room and fusion imaging (FI) technologies, based on a three-dimensional preoperative computed tomography angiography (CTA) image over-laid on a two-dimensional live fluoroscopy image, are useful tools to reduce intraoperative contrast medium and fluoroscopy time.
研究设计
- 研究类型
- Observational
- 观察模型
- Case Control
- 时间视角
- Prospective
入排标准
- 年龄范围
- 18 Years 至 99 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Patients with complex aortic aneurysms eligible for FEVAR.
- •Obtaining informed consent.
- •Age >18 years at the time of diagnosis
排除标准
- •Age <18 years at the time of diagnosis
结局指标
主要结局
Number of participants with perioperative renal function worsening
时间窗: 30-day
according to RIFLE classification
Reintervention and mortality
时间窗: 30-day
In-hospital/30-day
Rate of TVVs instability
时间窗: through study completion, an average of 1 year
Freedom from TVVs instability
Number of participants with renal function worsening
时间窗: through study completion, an average of 1 year
Freedom from renal function worsening
Rate of reintervention
时间窗: through study completion, an average of 1 year
Freedom from reintervention
Rate of technical success
时间窗: 24-hour
correct endograft deployment with stenting and patency of all planned TVVs and absence of type I and type III endoleaks, iliac leg stenosis or kinking and mortality at 24 hours
Rate of survival
时间窗: through study completion, an average of 1 year
Survival
次要结局
未报告次要终点
研究者
Enrico Gallitto
Principal Investigator
University of Bologna