NCT00751283WithdrawnPhase 2
Minnow Medical GRST Peripheral Catheter System First-in-Man Study Radiofrequency for the Treatment of Peripheral Vascular Occlusive Disease of the Lower Extremities
Conditions
Interventions
Trial Snapshot
- Phase
- Phase 2
- Status
- Withdrawn
- Sponsor
- Vessix Vascular, Inc
- Primary Endpoint
- Major adverse clinical events rate
Study Overview
Brief Summary
The purpose of this study is to evaluate the safety and efficacy of the Minnow Medical GRST Peripheral Catheter System in the treatment of new lesions in the superficial femoral artery or the popliteal artery.
Study Design
- Study Type
- Interventional
- Allocation
- Non Randomized
- Intervention Model
- Single Group
- Primary Purpose
- Treatment
- Masking
- None
Eligibility Criteria
- Ages
- 18 Years to — (Adult, Older Adult)
- Sex
- All
- Accepts Healthy Volunteers
- No
Inclusion Criteria
- •Patient is ≥18 years of age
- •Patient is Rutherford category 2-4
- •De novo lesion in the SFA or popliteal artery with a diameter stenosis ≥50%
- •Target lesion is a de novo occlusion that can be successfully pre-dilated resulting in a lesion of <99%
- •Target lesion stenosis has a length of ≤100 mm based on visual assessment
- •Target vessel reference diameter is ≥3.0 mm and ≤7.0 mm based on visual assessment
- •Angiographic evidence of distal runoff defined as minimum one (1) patent tibial artery with a straight flow to the foot
- •Patient is willing and able to provide written informed consent prior to any study specific procedure
- •Patient is willing and able to comply with specified follow-up evaluations at the specified times
Exclusion Criteria
- •Any prior intervention in the intended target lesion including 10 mm proximal or distal from the intended treatment area
- •Evidence of thrombus in the target vessel
- •Prior ipsilateral or contralateral lower limb arterial bypass
- •Treatment of ipsilateral lesions during the index procedure or planned treatment after the index procedure
- •Target lesion is severely calcified
- •Any known allergies and / or intolerances to the following: ASA, Clopidogrel, Heparin, contrast agents (that cannot be adequately pre-medicated).
- •Any planned surgery within 30 days of the study procedure.
- •Renal failure (serum creatinine > 2.0 mg/dL)
- •Female with childbearing potential without a negative pregnancy test
- •Patient has had an organ transplant
- •Patient is currently participating in an investigational drug or device study which has not reached the primary endpoint yet or which clinically interferes with the endpoints of this study
- •In the investigator's opinion, the patient has a severe co-morbid condition(s) that could limit the ability to participate in the study
Arms & Interventions
1
Experimental
GRST Peripheral Catheter System
Intervention: GRST Peripheral Catheter System (Device)
Outcomes
Primary Outcomes
Major adverse clinical events rate
Time Frame: Up to 30 days
Secondary Outcomes
- Amputation rate(30 days, 3 months, 6 months)
- Binary restenosis(30 days, 3 months, 6 months)
- Target lesion revascularization(30 days, 3 months, 6 months)
- Technical success(Treatment)
- Serious adverse events rate, including major adverse clinical events(30 days, 3 months, 6 months)
Investigators
Similar Trials
Active, not recruiting
Not Applicable
Clinical Investigation of Clinical Safety and Performance of the SP-GRIPFLOW, Selective Cerebral Perfusion Catheter When Used for Cerebral Perfusion During Aortic Arch RepairAortic Arch Aneurysm, DissectingAortic AneurysmAortic DissectionAortic Arch AneurysmNCT05421130Fuji Systems Corporation149
Completed
Not Applicable
A Pilot Study Evaluating the Safety and Effectiveness of a New Pleural Catheter for the Medical Management of Symptomatic, Recurrent, Malignant Pleural EffusionsMalignant Pleural EffusionsNCT02227732C. R. Bard10
Terminated
Not Applicable
Evaluation of the Safety and Clinical Performance of the Connected Catheter StudyChronicUrinary RetentionNCT05330598Spinal Singularity26
Recruiting
Not Applicable
FIH Study of the GEMINUS TAVI System in Patients With Severe Symptomatic Aortic StenosisAortic Valve StenosisNCT05909748Valve Medical30
Completed
Not Applicable
Safety and Effectiveness of a New Pleural Catheter for Symptomatic, Recurrent, MPEs Versus Approved Pleural CatheterMalignant Pleural EffusionNCT02649894C. R. Bard119