5 Year Clinical and Radiographic Follow-up of the Uncemented Symax Hip Stem in an International Study

Maastricht University Medical Center0 sites80 target enrollmentStarted: November 2, 2004Last updated:
Conditions
Interventions

Trial Snapshot

Phase
Not Applicable
Status
Completed
Enrollment
80
Primary Endpoint
Change of Harris Hip Score (HHS) during follow-up

Study Overview

Brief Summary

The uncemented Symax hip stem is developed through optimization of the uncemented Omnifit hip stem. The Symax stem design combines an anatomical anteverted proximal geometry with a straight distal section. The proximal part is coated with a biomimetic hydroxyapatite (HA) coating for improved osseointegration to enhance load transfer and to minimize proximal bone loss. The distal part is treated with an anodization surface treatment in order to prevent distal bone apposition, which is expected to prevent distal loading and reduce proximal stress shielding. Aim of this study is to report mid-term clinical performance and evaluate whether the radiographic features are in line with the design principles of the Symax hip in an international clinical study with 5 years of follow-up.

Study Design

Study Type
Interventional
Allocation
Na
Intervention Model
Single Group
Primary Purpose
Treatment
Masking
None

Eligibility Criteria

Ages
18 Years to 70 Years (Adult, Older Adult)
Sex
All
Accepts Healthy Volunteers
No

Inclusion Criteria

  • •Patients requiring uncemented primary total hip arthroplasty (osteoarthritis, avascular necrosis and/or post-traumatic arthritis), age between 18-70 years, BMI less or equal to 35.

Exclusion Criteria

  • •Patients with bilateral hip complaints, impaired cognitive function and use of medication or illness influencing bone metabolism.

Arms & Interventions

Symax uncemented hip stem

Other

The Symax hip stem is an uncemented design forged from Ti6Al4V alloy (Stryker EMEA). Primary mechanical stability is provided by anatomical metaphyseal geometry. The hip stem features a size dependent anteversion, neck length and offset, with a CCD angle of 128°. Secondary biological stability is accomplished by fast osseous integration due to the BONIT-HA coating on the metaphyseal part of the stem.

Intervention: Symax uncemented hip stem (Device)

Outcomes

Primary Outcomes

Change of Harris Hip Score (HHS) during follow-up

Time Frame: Preoperative HHS and postoperatively change in HHS at 6 months, 1 year, 2 years, 3 years and 5 years

A hip specific functional score

Secondary Outcomes

  • Radiographic evaluations(Immediately postoperative radiograhpic evaluation as baseline and changes in radiography at follow-up 6 months, 1 year, 2 years, 3 years and 5 years we evaluated the radiograhip evaluations again)