Brief Summary

The investigators are conducting research to compare serum and urine titanium levels in children with early onset scoliosis who are being treated with certain types of metal spinal rods. These rods include traditional growing rods (TGR), magnetically-controlled growing rods (MCGR), and Vertical Expandable Prosthetic Titanium Rib (VEPTR). Children with metal rods may have elevated serum and urine titanium levels. These levels may remain elevated over time. The investigators will collect serum titanium levels from children with metal rods and children without metal rods to see if there are differences in their titanium levels. The investigators will then collect a second serum titanium level from children with metal rods at least 6 months later to see if the participants titanium levels remain elevated over time. The investigators will also collect urine titanium levels from children with metal rods to see if titanium is excreted in the urine.

Detailed Description

Not available

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
38
Inclusion Criteria

Cases: Patients with early onset scoliosis treated with traditional growing rods (TGR), magnetically controlled growing rods (MCGR), and the Vertical Expandable Prosthetic Titanium Rib (VEPTR).

Controls: Patients with operative fractures.

Read More
Exclusion Criteria

Cases: Patients who had a previous limited spinal fusion, conversion from one type of GSI to another, TGR with stainless steel or cobalt chromium instrumentation, and indwelling implants for 6 months or less.

Controls: Patients with indwelling implants or prior implant insertion and removal.

Read More

Study & Design

Study Type
OBSERVATIONAL
Study Design
Not specified
Arm && Interventions
GroupInterventionDescription
Early onset ScoliosisGrowth-sparing instrumentation and titanium levelsPatients with early onset scoliosis treated with growth-sparing instrumentation (TGR, MCGR, and, VEPTR).
Primary Outcome Measures
NameTimeMethod
Serum titanium levels between groupsAt enrollment

Compare serum titanium levels in patients with EOS treated with titanium alloy TGR, MCGR, and VEPTR to age-matched controls.

Serial serum titanium levels in scoliosis patientsRoughly 6 months apart

Collect serial serum titanium levels in patients with EOS treated with TGR, MCGR, and VEPTR.

Urine titanium levels in scoliosis patientsAt enrollment

Collect urine titanium levels in patients with EOS treated with TGR, MCGR, and VEPTR.

Secondary Outcome Measures
NameTimeMethod

Trial Locations