Pilot Study of the ACE System in Lung Procedures
- Conditions
- Lung Diseases
- Interventions
- Device: XACT ACE Robotics study arm
- Registration Number
- NCT04651517
- Lead Sponsor
- Xact Robotics Ltd.
- Brief Summary
To evaluate the XACT ACE Robotic System in lung procedures.
- Detailed Description
The XACT ACE Robotic System is a user-controlled positioning system intended to assist in the planning and advancement of an instrument during Computed Tomography (CT) guided percutaneous lung procedures. The system is used for trajectory planning and is intended to assist the physician in the positioning of an instrument, such as a needle, where CT imaging is used for target trajectory planning and intraoperative tracking. This study will evaluate safety and accuracy of the XACT ACE Robotic System in subjects undergoing CT guided, minimally invasive percutaneous procedures of the lung in the interventional radiology suite.
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 20
- 18 years of age
- Subjects undergoing CT-guided, minimally invasive percutaneous lung procedures in the interventional radiology suite, e.g., core biopsy, fine needle aspiration (FNA), tumor ablation, etc.
- Following planning and registration CT scans, subject is found eligible to undergo CT-guided, minimally invasive percutaneous procedure
- Subject is willing to sign informed consent
- Subject is capable of adhering to study procedures
- Subjects in whom the target is within 1 cm of a major blood vessel, major nerve or heart
- Subject with significant coagulopathy
- Subject with preexisting or unstable medical condition(s), which in the opinion of the investigator, might interfere with the conduct of the study
- Subjects who are pregnant or nursing
- Following planning and registration CT scans, required clinical trajectory to target is beyond system workspace limits (e.g., entry angle is too sharp)
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- SINGLE_GROUP
- Arm && Interventions
Group Intervention Description Study arm XACT ACE Robotics study arm Subjects undergoing procedures with the XACT ACE Robotic system.
- Primary Outcome Measures
Name Time Method Adverse Events 30 days Incidence, severity, and frequency of adverse events and device-related adverse events
- Secondary Outcome Measures
Name Time Method Secondary Performance Evaluation - Clinical Accuracy 1 hour Percent of procedures in which the needle reached the pre-defined target based on the physician's determination and CT imaging confirmation (clinical accuracy)
Secondary Performance Evaluation - System Accuracy 1 hour The measured distance from the tip of the needle/tool to the target location at the end of the needle/tip insertion.
Trial Locations
- Locations (1)
Lahey Hospital and Medical Center
🇺🇸Burlington, Massachusetts, United States