Percutaneous Ultrasound-Guided Biopsy Evaluated for Axillary Lymph Node Sampling Efficacy (PULSE)
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- 入组人数
- 140
- 试验地点
- 7
- 主要终点
- Rate of successful biopsies (= success rates)
研究概览
简要总结
The aim of the study is to document performance characteristics of a biopsy device indicated for use in axillary lymph nodes, to provide basic insights into the complexity of axillary biopsy procedures and generate hypothesis for further larger comparative trials.
This is a Sponsor-initiated prospective, multicenter, registry trial. Patients that present with suspicious axillary lymph nodes at the time of breast cancer diagnosis undergo axillary sampling using the NeoNavia biopsy system. This is in accordance with clinical routine and current clinical guidelines. The system incorporates a new mechanism for controllable and precise needle insertion and a newly developed sampling needle for high yield sampling acquisition. It is approved for use in the breast and axillary lymph nodes.
详细描述
Determining axillary nodal status at the time of diagnosis is paramount for optimal staging and treatment planning. SLNB is indicated for patients with a clinical and radiological negative axilla. 25%-43% of breast cancer patients are reported to present with radiologically suspicious axillary lymph nodes at the time of diagnosis. In these patients, a pre-operative ultrasound-guided needle sampling of suspicious axillary lymph tissue is indicated.
This can rationalize patient care by identifying those with axillary metastases using merely a minimally-invasive intervention. These patients can be counselled with regards to proceeding directly to definitive axillary surgery in the form of axillary lymph node dissection (ALND) rather than sentinel node biopsy (SLNB), thereby omitting a potentially unnecessary surgical procedure. Patients with a negative axillary status can proceed to SLNB for definitive nodal status determination. Furthermore, in the paradigm of neoadjuvant treatment, confirming a histopathologic involvement of lymph nodes by US-guided needle biopsies enables for decision on neoadjuvant chemotherapy without the need for a surgical procedure.
The main challenge in performing CNB (Core Needle Biopsy) within the axilla is to avoid damaging the major vessels and nerves. Technical, operator and procedural requirements that mitigate risks in CNB sampling of the axilla have been reported in the literature. It is suggested that the operator shall fully acknowledge the detailed anatomy including vessels and nerves in the axilla, have good hand-eye coordination as well as be experienced in US-guided interventions. Proper positioning of the patient is reported to be important. Color Doppler ultrasound shall be used to assess the location of large vessels relative to the intended biopsy track and to avoid sampling a vascular component of the node. Perfect guiding and visualization of the needle tip at all times is reported to be essential. It is suggested that a biopsy device with a controllable needle action is safer to use. Omitting the firing action gives the operator greater control over the final needle tip placement.
Due to the difficulty of the procedure there may be inclusion bias in the reported studies. In one series, patients presenting with nodes adjacent to a vessel or located very deep and difficult to access were not asked to participate in the study and hence not subjected to CNB. In another study FNA (Fine Needle Aspiration) was performed instead of CNB when the lymph nodes were in close proximity to vessels. A recent German survey showed that merely 79% of breast centers (41/52) perform biopsies in the axilla (data on file), and anecdotal evidence suggests that in certain departments only the most experienced physician performs CNB procedures in axillary lymph nodes, risking economic/operational inefficiencies.
For the purpose of documenting the prevalence and composition of cases deemed challenging in this study, an experienced expert panel has compiled a comprehensive list of risk parameters characterizing the anatomic complexity and procedural difficulty of axillary lymph node needle biopsies.
研究设计
- 研究类型
- Observational
- 观察模型
- Case Only
- 时间视角
- Prospective
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •cT1-4c (multifocality / multicentricity permitted)
- •Female / male patient aged ≥ 18 years
- •cN+ based on the following criteria (at least one criteria must be met):
- •lymph node is palpable
- •cortical asymmetry (focal or diffuse cortical thickening of >3mm) under US
- •cortex:hilum ratio >2:1 under US
- •loss of hilum/cortex structure under US
- •Written informed consent (ICF)
排除标准
- •Suspicious lymph nodes after neoadjuvant therapy
- •No confirmed breast cancer and no abnormality in the breast
- •Patient uses Marcumar
- •Pregnant and lactating women
- •Known hypersensitivity reaction against local anesthesia
- •Prior chemo or radiation therapy in breast or axilla
- •Missing written informed consent
结局指标
主要结局
Rate of successful biopsies (= success rates)
时间窗: after histopathological analysis af tissue samples, up to 1 week after biopsy
Lymph node tissue present in biopsy samples as assessed by histopathologist
次要结局
- Rate of cases in which pulses facilitated control during needle insertion(time of biopsy, 1 day)
- Sensitivity(post-surgery, up to 200 days)
- Rate of patients presenting with risk parameters for an anatomically complex procedure(time of biopsy, 1 day)
- Rate of cases in which it was possible to target the selected lymph node or, if present, the lesion inside the node(time of biopsy, 1 day)
- Specificity(post-surgery, up to 200 days)