Pulmonary Vein Isolation Plus Left Atrial Slow Zone Mapping and Ablation An AcQMap Substrate Characterization Study (PLASZMA)
试验速览
- 阶段
- 不适用
- 状态
- 撤回
- 主要终点
- Number of Participants With Freedom From Device/Procedure Related Major Adverse Events (MAEs)
研究概览
简要总结
Pulmonary Vein Isolation Plus Left Atrial Slow Zone Mapping and Ablation: An AcQMap Substrate Characterization Study (PLASZMA)
详细描述
The AcQMap Imaging and Mapping System® is intended for use in patients for whom electrophysiology procedures have been prescribed.
When used with the AcQMap Catheters, the AcQMap System is intended to be used to reconstruct the selected chamber from ultrasound data for purposes of visualizing the chamber anatomy and displaying electrical impulses as either charge density-based or voltage-based maps of complex arrhythmias that may be difficult to identify using conventional mapping systems alone.
AND
When used with specified Patient Electrodes, the AcQMap System is intended to display the position of the AcQMap Catheters and conventional electrophysiology (EP) catheters in the heart.
OR
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 主要目的
- Diagnostic
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 80 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Male or female ≥ 18 years of age at the time of consent
- •Clinically indicated and scheduled for a de novo catheter ablation of a complex left atrial arrhythmia including AF/AT/AFL
- •Willing and able to provide written informed consent to participate in the study and agree to comply with all follow-up visits and evaluations for the duration of the study.
排除标准
- •In the opinion of the investigator, any contraindication to the planned atrial ablation, including anticoagulation contraindications, renal failure, or sepsis.
- •Atrial arrhythmias secondary to electrolyte imbalance, thyroid disease, or any other reversible or non-cardiac cause.
- •Any DCCV within 60-days of the index procedure where sinus rhythm was not maintained for at least 60-minutes.
- •Any cardiac defibrillator (ICD) or pacemaker implanted within 8-weeks prior to the ablation procedure.
- •History of previous left atrial ablation (including surgical treatment) for AF/AT/AFL.
- •Structural heart disease or cardiac history including:
- •Left ventricular ejection fraction (LVEF) < 35% based on a 2-d transthoracic echocardiogram (TTE) within the previous 180-days prior to enrollment.
- •Left atrial size > 60 mm (parasternal long-axis view) based on 2-d TTE within the previous 180-days prior to enrollment.
- •Prior history of New York Heart Association (NYHA) Class IV heart failure.
- •Any evidence of NYHA Class III heart failure in the previous 3-months prior to enrollment.
- •Unstable angina or ongoing myocardial ischemia.
- •Myocardial infarction (STEMI) within the previous 180-days (sub-endocardial infarct within previous 90-days) prior to enrollment.
- •Moderate or severe valvular heart disease (stenosis or regurgitation).
- •Presence of a left atrial appendage occlusion device.
- •Body Mass Index (BMI) > 40kg/m2
- •History of blood clotting or bleeding disease.
- •History of chronic obstructive pulmonary disease (COPD) requiring use of oxygen in the treatment regimen.
- •History of obstructive sleep apnea not currently being treated.
- •Pregnant or lactating (current or anticipated during study follow-up).
结局指标
主要结局
Number of Participants With Freedom From Device/Procedure Related Major Adverse Events (MAEs)
时间窗: 6 Months
MAEs inlcude: death, myocardial infarction, cardiac perforation/tamponade, cerebral infarct, or systemic embolism, Major bleeding requiring transfusion of blood products, Mitral or tricuspid valve damage, Symptomatic pulmonary vein (PV) stenosis, Asymptomatic PV stenosis ≥ 70%, Permanent phrenic nerve injury, Access site complications requiring pharmacological or surgical intervention, Atrio-esophageal fistula, Pericarditis, Heart block requiring a permanent pacemaker, Vagal nerve injury leading to gastroparesis, Other serious adverse device effects (SADEs), including transient ischemic attack (TIAs), adjudicated as "probably or definitely related" to the AcQMap System
次要结局
- Number of Participants Who Experienced at Least One procedure and device related Serious Adverse Events.serious adverse device effects (SADEs), and all unanticipated device effects (UADEs)(6 Months)