Randomized, Controlled, Single-Center, Cross-Over Clinical Study to Evaluate Tear Characteristics Following Acute TrueTear™ Use

Allergan2 个研究点 分布在 1 个国家目标入组 10 人开始时间: 2017年10月18日最近更新:
适应症

试验速览

阶段
不适用
状态
终止
发起方
Allergan
入组人数
10
试验地点
2
主要终点
Change From Baseline (Pre-application) in Tear Meniscus Height (TMH) at Eye Opening and Pre-Blink

研究概览

简要总结

This study will evaluate the change in tear meniscus height (TMH) produced by intranasal stimulation with TrueTear™ compared with the same device applied extranasally (control).

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Crossover
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Baseline Ocular Surface Disease Index© (OSDI©) score of at least 23 with no more than three responses of "not applicable"
  • In at least one eye, a baseline Schirmer test of ≤ 10 mm/5 minutes AND a cotton swab nasal stimulation Schirmer test of at least 7 mm higher in the same eye

排除标准

  • Chronic or recurrent epistaxis, coagulation disorders or other conditions that may increase the risk of bleeding
  • History of nasal or sinus surgery
  • Vascularized polyp, deviated septum or severe nasal airway obstruction at the Screening visit
  • Intraocular and extraocular surgery in either eye within three months of the Screening Visit or refractive surgery within twelve months of the Screening Visit
  • Cardiac demand pacemaker, implanted defibrillator, or other active implanted metallic or active implanted electronic device in the head

结局指标

主要结局

Change From Baseline (Pre-application) in Tear Meniscus Height (TMH) at Eye Opening and Pre-Blink

时间窗: Pre-application (Day 0) to time (T) 0 (immediately), 15, 30, 60, 120, 180, 240, 300 and 360 minutes on Day 0 after application

Tear meniscus height is defined as the mean height of the lower tear prism to the edge of the eye lid measured by the investigator using the Tear scope Plus in conjunction with a Topcon SL-D7 slit lamp biomicroscope and high-resolution digital video recording. Change from Baseline to time (T) T0 (immediately), T15, T30, T60, T120, T180, T240, T300, T360 minutes (mins) after application was reported. A negative change from Baseline (Pre-application) indicates improvement.

Change From Baseline (Pre-application) in Tear Lipid Layer Thickness at Eye Opening and Pre-Blink

时间窗: Pre-application (Day 0) to time (T) 0 (immediately), 15, 30, 60, 120, 180, 240, 300 and 360 minutes on Day 0 after application

Lipid layer thickness is defined as the average thickness of the lipid layer calculated from the thickness of the various pattern weighted by the relative coverage of each pattern measured by the investigator using the Tearscope Plus in conjunction with a Topcon SL-D7 slit lamp biomicroscope and high-resolution digital video recording. Change from Baseline to T0 (immediately), T15, T30, T60, T120, T180, T240, T300, T360 mins after application was reported. A negative change from Baseline (Pre-application) indicates improvement .

Change From Baseline (Pre-application) in Non-Invasive Tear Film Break-Up Time (NIBUT)

时间窗: Pre-application (Day 0) to time (T) 0 (immediately), 15, 30, 60, 120, 180, 240, 300 and 360 minutes on Day 0 after application

Non-invasive break-up time is the time in seconds between eye opening and the appearance of the first visible break in the lipid layer of the pre-corneal tear film measured by the investigator using the Tearscope Plus in conjunction with a Topcon SL-D7 slit lamp biomicroscope and high-resolution digital video recording. Change from Baseline to T0 (immediately), T15, T30, T60, T120, T180, T240, T300, T360 mins after application was reported. A negative change from Baseline (Pre-application) indicates improvement.

Change From Pre-application in Protective Index (PI)

时间窗: Pre-application (Day 0) to time (T) 0 (immediately), 15, 30, 60, 120, 180, 240, 300 and 360 minutes on Day 0 after application

The Protected Index (PI) corresponds to the percentage of the corneal surface that is not exposed to the atmosphere (i.e. fully covered by the tear film) over the full interblink period measured by the investigator using a Tear scope Plus in conjunction with a Topcon SL-D7 slit lamp biomicroscope and high-resolution digital video recording. Change from Baseline to T0 (immediately), T15, T30, T60, T120, T180, T240, T300, T360 mins after application was reported.

Change From Pre-application in Exposed Area (EA)

时间窗: Pre-application (Day 0) to time (T) 0 (immediately), 15, 30, 60, 120, 180, 240, 300 and 360 minutes on Day 0 after application

Exposed Area is defined as the percentage of the observed area not covered by the tear film at the time of the blink hence exposed to the atmosphere measured by the investigator using a Tear scope Plus in conjunction with a Topcon SL-D7 slit lamp biomicroscope and high-resolution digital video recording. Change from Baseline to T0 (immediately), T15, T30, T60, T120, T180, T240, T300, T360 mins after application was reported.

次要结局

未报告次要终点

研究者

发起方
Allergan
申办方类型
Industry
责任方
Sponsor

研究点 (2)

Loading locations...

相似试验