MedPath

Outcomes of Transcatheter Aortic Valve Implantation in Management of Severe Symptomatic Aortic Stenosis

Conditions
Aortic Valve Stenosis
Interventions
Device: Transcatheter aortic valve
Registration Number
NCT03633383
Lead Sponsor
Assiut University
Brief Summary

TAVI is still a relatively new technique that is emerging with advance in the percutaneous and implantable valve technology. Despite its safe use in inoperable and high risk patients with severe symptomatic aortic valve stenosis, minimizing complications, predictors of outcomes and approach preference is still an area of study. Here we decided to study the outcomes of patients undergoing TAVI, different approaches used and their subsequent results and complications.

Detailed Description

Severe symptomatic aortic stenosis in elderly patients represents a surgical challenge for cardiac surgeons due to heavy calcifications and associated comorbidities. Such conditions usually are associated with dramatic intra and postoperative complications leading to many cases being declined for open surgical replacement. Many treatment modalities were described including trans-catheter valvotomy but with only temporary improvements and high rates of recurrence.

Transcatheter Aortic Valve Implantation (TAVI) has offered an alternative solution to such cases in which open surgery is deemed too risky or prohibited. Percutaneous Heart Valves (PHV) implantations have been experimented on animals since the early 1990s. Yet the first human case was not reported till 2002, in which a percutaneously implanted heart valve (PHV) composed of 3 bovine pericardial leaflets mounted within a balloon-expandable stent was developed and implanted through the antegrade trans-septal approach in a patient presenting with severe calcific aortic stenosis associated with many noncardiac comorbidities including leg ischaemia. Despite Patient's death after 17 weeks due to noncardiac causes, his follow-up showed significant improvement of left ventricle (LV) function and aortic valve area after implantation of the percutaneous valve.

This case was followed by several single-center and small multicenter registries and series that included inoperable or very-high-risk patients, which were associated with promising results that confirmed the feasibility of TAVI.

Many approaches are used for TAVI with the transfemoral approach being the primary option. Abnormalities of the iliofemoral anatomy have led to the emergence of other approaches including transapical, subclavian, axillary, and transaortic routes. Potential advantages of such approaches would be the avoidance of using large catheters though the iliofemoral system, aortic arch, ascending aorta, and aortic valve. Yet, their main disadvantage would be the need for general anaesthesia.

As any surgical procedure, TAVI carries some risk of complications, major vascular injuries, stroke, conduction abnormalities, myocardial infarction, coronary obstruction and acute kidney injury have been reported. Although, careful planning, patient selection, perioperative workup and individualised approach choice play an important role in avoiding such problems.

Recruitment & Eligibility

Status
UNKNOWN
Sex
All
Target Recruitment
50
Inclusion Criteria
  • Patients with severe symptomatic aortic stenosis undergoing TAVI.
Exclusion Criteria
  • Patients with concomitant valvular heart disease.

Study & Design

Study Type
OBSERVATIONAL
Study Design
Not specified
Arm && Interventions
GroupInterventionDescription
Transapical ApproachTranscatheter aortic valve-
Transfemoral ApproachTranscatheter aortic valve-
Primary Outcome Measures
NameTimeMethod
All cause mortalityone month

Causes of mortality such stroke, myocardial infarction, kidney injury,bleeding

Secondary Outcome Measures
NameTimeMethod
BleedingOne month after tavi

Amount of blood loss post Tavi

Hospital stayOne month

Calculated in days

Acute kidney injuryOne month

According to RIFLE system

StrokeOne month

Major or minor

Myocardial infarctionOne month after tavi
Number of patients with conduction disturbance and pacemaker implantation6 months

AV block by Electrocardiogram

Gradient on implanted valveOne month

By echocardiography measured in mmhg

Degree of transvalvular leakageOne month

By echocardiography divided in no, mild, moderate and severe

© Copyright 2025. All Rights Reserved by MedPath