Outcomes of Transcatheter Aortic Valve Implantation in Management of Severe Symptomatic Aortic Stenosis
- Conditions
- Aortic Valve Stenosis
- Interventions
- Device: Transcatheter aortic valve
- Registration Number
- NCT03633383
- Lead Sponsor
- Assiut University
- Brief Summary
TAVI is still a relatively new technique that is emerging with advance in the percutaneous and implantable valve technology. Despite its safe use in inoperable and high risk patients with severe symptomatic aortic valve stenosis, minimizing complications, predictors of outcomes and approach preference is still an area of study. Here we decided to study the outcomes of patients undergoing TAVI, different approaches used and their subsequent results and complications.
- Detailed Description
Severe symptomatic aortic stenosis in elderly patients represents a surgical challenge for cardiac surgeons due to heavy calcifications and associated comorbidities. Such conditions usually are associated with dramatic intra and postoperative complications leading to many cases being declined for open surgical replacement. Many treatment modalities were described including trans-catheter valvotomy but with only temporary improvements and high rates of recurrence.
Transcatheter Aortic Valve Implantation (TAVI) has offered an alternative solution to such cases in which open surgery is deemed too risky or prohibited. Percutaneous Heart Valves (PHV) implantations have been experimented on animals since the early 1990s. Yet the first human case was not reported till 2002, in which a percutaneously implanted heart valve (PHV) composed of 3 bovine pericardial leaflets mounted within a balloon-expandable stent was developed and implanted through the antegrade trans-septal approach in a patient presenting with severe calcific aortic stenosis associated with many noncardiac comorbidities including leg ischaemia. Despite Patient's death after 17 weeks due to noncardiac causes, his follow-up showed significant improvement of left ventricle (LV) function and aortic valve area after implantation of the percutaneous valve.
This case was followed by several single-center and small multicenter registries and series that included inoperable or very-high-risk patients, which were associated with promising results that confirmed the feasibility of TAVI.
Many approaches are used for TAVI with the transfemoral approach being the primary option. Abnormalities of the iliofemoral anatomy have led to the emergence of other approaches including transapical, subclavian, axillary, and transaortic routes. Potential advantages of such approaches would be the avoidance of using large catheters though the iliofemoral system, aortic arch, ascending aorta, and aortic valve. Yet, their main disadvantage would be the need for general anaesthesia.
As any surgical procedure, TAVI carries some risk of complications, major vascular injuries, stroke, conduction abnormalities, myocardial infarction, coronary obstruction and acute kidney injury have been reported. Although, careful planning, patient selection, perioperative workup and individualised approach choice play an important role in avoiding such problems.
Recruitment & Eligibility
- Status
- UNKNOWN
- Sex
- All
- Target Recruitment
- 50
- Patients with severe symptomatic aortic stenosis undergoing TAVI.
- Patients with concomitant valvular heart disease.
Study & Design
- Study Type
- OBSERVATIONAL
- Study Design
- Not specified
- Arm && Interventions
Group Intervention Description Transapical Approach Transcatheter aortic valve - Transfemoral Approach Transcatheter aortic valve -
- Primary Outcome Measures
Name Time Method All cause mortality one month Causes of mortality such stroke, myocardial infarction, kidney injury,bleeding
- Secondary Outcome Measures
Name Time Method Bleeding One month after tavi Amount of blood loss post Tavi
Hospital stay One month Calculated in days
Acute kidney injury One month According to RIFLE system
Stroke One month Major or minor
Myocardial infarction One month after tavi Number of patients with conduction disturbance and pacemaker implantation 6 months AV block by Electrocardiogram
Gradient on implanted valve One month By echocardiography measured in mmhg
Degree of transvalvular leakage One month By echocardiography divided in no, mild, moderate and severe