跳至主要内容
临床试验/NCT01342822
NCT01342822Unknown不适用

A Prospective, Randomized, Multi-center Trial to Assess the Everolimus-Eluting Coronary Stent System (PROMUS Element) for Coronary Revascularization in a Population of Unrestricted Patients

European Cardiovascular Research Center49 个研究点 分布在 8 个国家目标入组 2,980 人开始时间: 2010年10月最近更新:
适应症

试验速览

阶段
不适用
发起方
入组人数
2,980
试验地点
49
主要终点
Target Vessel failure (TVF)

研究概览

简要总结

The PROMUS Element™ clinical trial (PLATINUM-PLUS) consists of a randomized controlled trial (RCT) in the European Union (EU) which will enroll approximately 2980 subjects (2:1 randomization PROMUS Element™: Xience™ Prime) in a Population of consecutive, all comers in the reimbursed indications per-country

All subjects will be screened per the protocol required inclusion/exclusion criteria.

详细描述

The PLATINUM-PLUS trial will investigate in a broad patient and lesion population, the CE Mark approved PROMUS Element™ Everolimus-Eluting Coronary Stent System (PROMUS Element), which combines the Element™ stent (the latest generation stent from Boston Scientific Corporation [BSC, Natick, Massachusetts, United States]), everolimus, and the poly (n butyl methacrylate) (PBMA) and poly (vinylidene fluoride co hexafluoropropylene) (PVDF-HFP) polymers. The PROMUS Element, received CE Mark on November 3rd 2009; it is currently under investigation in the PLATINUM clinical trial, and has great promise as it combines BSC's novel stent technology with the everolimus drug and polymers that have demonstrated excellent performance in the SPIRIT clinical program.

PROMUS Element comprises the following key components: everolimus, 2 polymers, and the Element stent component. The same everolimus and polymer combination is commercially available in many countries on the MULTI-LINK VISION™ stent. It is manufactured and distributed by Abbott as the XIENCE™ V Everolimus Eluting Coronary Stent System (XIENCE V), and also distributed by BSC as the identical stent system, also manufactured by Abbott, as the PROMUS™ Everolimus-Eluting Coronary Stent System (PROMUS). The names XIENCE V and PROMUS are used synonymously within this protocol.

While PROMUS Element is a new DES system, its constituent parts are either approved by the Food and Drug Administration (FDA, i.e., drug and polymers from PROMUS, P070015), are under investigation in an FDA-approved trial (i.e., Element stent component in the PERSEUS trial, G060237), or have received an approvable letter from the FDA. The balloon component material of the PROMUS Element delivery system is the same as that used in TAXUS Liberté (P060008), which received an approvable letter on February 11, 2008. The PROMUS Element stent delivery system is from the Apex™ Monorail™ PTCA Dilatation Catheter (P860019/S208), which received an approvable letter on October 24, 2006. Table 1 compares the TAXUS Express2, TAXUS Liberté, and PROMUS Element stent systems.

研究设计

研究类型
Observational
观察模型
Case Only
时间视角
Prospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • General Inclusion Criteria
  • The patient must be ≥18 of age
  • Symptomatic ischemic heart disease (CCS class 1-4, Braunwald Class IB, IC, and/or objective evidence of myocardial ischemia);
  • Acceptable candidate for CABG;
  • The patient is willing to comply with specified follow-up evaluations;
  • The patient or legally authorized representative has been informed of the nature of the study, agrees to its provisions and has been provided written informed consent, approved by the appropriate Medical Ethics Committee (MEC).
  • Angiographic Inclusion criteria:
  • Single or multiple native coronary artery or saphenous vein graft lesions in single or multiple vessels;
  • Patients with multi-lesion or multi-vessel coronary disease may undergo staged (planned) procedures within 30-days of the index procedure.
  • Reference vessel diameter must be ≥2.25 to ≤ 4.25 mm by visual estimate.

排除标准

  • Pregnant or nursing subjects and those who plan pregnancy in the period up to 1 year following index procedure. Female subjects of child-bearing potential must have a negative pregnancy test done within 7 days prior to the index procedure per site standard test;
  • Patients in whom anti-platelet and/or anticoagulant therapy is contraindicated;
  • Patient has other medical illness (e.g., cancer, known malignancy , congestive heart failure, organ transplant recipient or candidate) or known history of substance abuse (alcohol, cocaine, heroin etc.) that may cause non-compliance with the protocol, confound the data interpretation or is associated with a limited life expectancy (i.e., less than 1 year);
  • Patient has a known hypersensitivity or contraindication to aspirin, heparin/bivalirudin, clopidogrel/ticlopidine, prasugrel, platinum chromium alloy, everolimus, and/or contrast sensitivity that cannot be adequately pre-medicated;
  • Patient with LVEF <20%, cardiogenic shock, or hemodynamic compromise requiring pressors or inotropes or mechanical support devices
  • Any significant medical condition which in the Investigator's opinion may interfere with the patient's optimal participation in the study;
  • Currently participating in another investigational drug or device study. -

结局指标

主要结局

Target Vessel failure (TVF)

时间窗: 12 months

Target Vessel failure (TVF) of the PROMUS Element™ Everolimus-Eluting Coronary Stent at 12 months post-procedure. TVF is defined as any ischemia-driven revascularization of the target Vessel (TVR), MI (Q-wave and non-Q-wave) related to the target vessel, or cardiac death related to the target vessel.

次要结局

  • Clinical endpoints(30 days, 12 months and 24 months)

研究者

发起方
European Cardiovascular Research Center
申办方类型
Network
责任方
Sponsor

研究点 (49)

Loading locations...

相似试验