跳至主要内容
临床试验/NCT07453381
NCT07453381招募中不适用

Multisensor Wireless Pressure Microcatheter For Microvascular Function Assessment In ANOCA/INOCA Patients: A Prospective, Multicenter, Single-Group Target Value Study

Peking University Third Hospital7 个研究点 分布在 1 个国家目标入组 114 人开始时间: 2026年6月30日最近更新:

试验速览

阶段
不适用
状态
招募中
入组人数
114
试验地点
7
主要终点
Sensitivity and specificity of multi-sensor wireless pressure microcatheter for calculating Coronary Flow Reserve (CFR) in diagnosing Coronary Microvascular Dysfunction (CMD)

研究概览

简要总结

This study aims to evaluate the sensitivity and specificity of a multi-sensor wireless pressure microcatheter for the diagnosis of CMD in patients with ANOCA/INOCA, using quantitative myocardial perfusion imaging of cardiac magnetic resonance (CMR) as a reference.

详细描述

This is a prospective, multicenter, single-group target value study, which aims to enroll patients with angina symptoms or objective evidence of myocardial ischemia, whose coronary angiography visual assessment shows a diameter stenosis of <50% and an FFR >0.8 (or cRR >0.89).

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Age ≥ 18 years, gender not limited;
  • Symptoms of angina pectoris, or objective evidence of myocardial ischemia (e.g., electrocardiogram, myocardial injury markers, etc.);
  • Visual assessment of coronary angiography shows diameter stenosis < 50% and FFR > 0.8 (or cRR > 0.89);
  • Microvascular function assessment is planned;
  • Agree to participate in this clinical study and voluntarily sign the informed consent form.

排除标准

  • Acute myocardial infarction, PCI, CABG, or valvular surgery following angiography within the past 30 days;
  • Severe valvular disease requiring surgical or interventional treatment;
  • Chest pain with known non-ischemic causes (e.g., pericarditis, pulmonary hypertension, esophageal spasm);
  • Contraindications to CMR (e.g., certain types of pacemakers or defibrillators, severe claustrophobia);
  • Clear contraindications to adenosine and ATP use (e.g., second- or third-degree atrioventricular block, sick sinus syndrome, severe asthma, systolic blood pressure below 90 mmHg);
  • Renal insufficiency (eGFR ≤ 45 mL/min/1.73 m2) or currently undergoing dialysis;
  • Severe heart failure or LVEF ≤ 35%;
  • Severe organ disease or life expectancy less than 2 years;
  • Known to be participating in other drug or device clinical trials that have not yet met the primary endpoint;
  • Other investigators deem the candidate unsuitable for this clinical trial.

结局指标

主要结局

Sensitivity and specificity of multi-sensor wireless pressure microcatheter for calculating Coronary Flow Reserve (CFR) in diagnosing Coronary Microvascular Dysfunction (CMD)

时间窗: Intraoperative period (day 0) and post-operative (days 1-7)

Using study participants as the unit of study, and with Myocardial Perfusion Reserve (MPR) calculated by Cardiac Magnetic Resonance (CMR) quantitative myocardial perfusion imaging as the reference (MPR\<2.2 is positive, MPR≥2.2 is negative), the sensitivity and specificity of CFR calculated by multi-sensor wireless pressure microcatheter for diagnosing CMD (CFR\<2.5 is positive, CFR≥2.5 is negative) were evaluated.

次要结局

  • Multi-sensor wireless pressure microcatheter calculation of CFR for diagnosing CMD: accuracy, positive predictive value, negative predictive value, Receiver Operating Characteristic Curve (ROC), and Area Under the Curve(AUC)(Intraoperative period (day 0) and post-operative (days 1-7))
  • Pearson correlation analysis and Bland-Altman bias analysis of CFR calculated by multi-sensor wireless pressure microcatheter and MPR calculated by CMR quantitative myocardial perfusion imaging.(Intraoperative period (day 0) and post-operative (days 1-7))
  • Pearson correlation analysis of multi-sensor wireless pressure microcatheter measurements of Tmn,rest and Tmn,hyper with CMR quantitative myocardial perfusion imaging measurements of MBFrest and MBFhyper.(Intraoperative period (day 0) and post-operative (days 1-7))
  • Multi-sensor wireless pressure microcatheter calculation of Index of Microcirculatory Resistance (IMR) for diagnosing CMD: accuracy, sensitivity, specificity, positive predictive value, negative predictive value, ROC, and AUC.(Intraoperative period (day 0) and post-operative (days 1-7))
  • Multi-sensor wireless pressure microcatheter calculation of Microvascular Resistance Reserve (MRR) for diagnosing CMD: accuracy, sensitivity, specificity, positive predictive value, negative predictive value, ROC, and AUC.(Intraoperative period (day 0) and post-operative (days 1-7))

研究者

申办方类型
Other
责任方
Sponsor

研究点 (7)

Loading locations...