Heart Rate Variability in Patients With Neurogenic Detrusor Overactivity Before and After Botulinum Neurotoxin Type A Intradetrusor Injections
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- 入组人数
- 36
- 试验地点
- 1
- 主要终点
- Changes in frequency and time
研究概览
简要总结
Heart rate variability (HRV) is an important indicator of cardiac autonomic function and predictor of cardiac mortality and of all-cause mortality. In this study the investigators examined changes of the HRV in patients with neurogenic detrusor overactivity (NDO) undergoing botulinum neurotoxin type A intradetrusor injections (BoNT/A).
详细描述
BoNT/A is a common treatment in patients with NDO. Possible known side effects are urinary retention or increased post void residual. Systemic side effects seems to be rare. However this has not been investigated in detail. Although in very small amounts, BoNT/A can enter the systemic circulation during intradetrusor injections and might cause distant effects on other neuro-muscular systems, i.e. the heart. Aim of this trial is to asses potential systemic adverse effects of BoNT/A on the heart following intradetrusor injections for NDO. Potential effects on the cardiac autonomic function can be detected using HRV analysis. Patients without relevant preexisting disorders of cardiac function and proven NDO are included. During four separate visits, all subjects receive two ECG measurements before (Visit 1 and 2) and two ECG measurements following BoNT/A intradetrusor injections (Visit 3 and 4). We investigate three different groups: 1) patients not receiving BoNT/A intradetrusor injections (= control group), 2) patients receiving intradetrusor injections with 100 units BoNT/A, and 3) patients receiving intradetrusor injections with 300 units BoNT/A.
研究设计
- 研究类型
- Observational
- 观察模型
- Case Control
- 时间视角
- Prospective
入排标准
- 年龄范围
- 18 Years 至 80 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •patient with neurogenic detrusor overactivity
- •written informed consent
- •Medical indication for BoNT/A injections
- •able to learn or conduct clean intermittent self-catheterization
排除标准
- •No written informed consent
- •Pregnancy
- •Cancer of infection of the lower urinary tract
- •Cardiac pacemaker
- •Previous heart attack, angina pectoris
- •Medication with effect on HRV
- •Previous cardiosurgery
- •Cardiac arrhythmia
- •Skin disease not allowing application of ECG-electrodes
结局指标
主要结局
Changes in frequency and time
时间窗: The outcome measures (VLF, LF and HF, SDNN and RMSSD are measured with an ECG recording during 10 minutes, at four different time points (two times before, and two times following the BoNT/A application
Changes in frequency (low frequency (LF), high frequency (HF), low frequency/highfrequency (LF/HF)) and time (domain parameters. This include the root mean square of differences of successive NN (normal to normal, i.e. interval between two R peaks) intervals (RMSSD), and the standard deviation of the NN intervals (SDNN)
次要结局
- Adverse events related to BoNT/A injection (urinary tract infection, urinary retention, increasing postvoiding urine, need for intermittend catheterization(This outcome measured will be evaluated at visit 4 (six weeks, following the BoNT/A application)
