Pocket Echocardiography System (PES) for Detection of Patent Ductus Arteriosus (PDA) in Neonates
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 50
- 试验地点
- 2
- 主要终点
- False Positives Results of Pocket Echocardiography System (PES) Detection of Patent Ductus Arteriosus (PDA) to Full Featured Echo System (FFES)
研究概览
简要总结
This is a single-center, feasibility study involving all neonates admitted to the neonatal intensive care unit with orders for a cardiac echo evaluation. Parents will be approached and provided a description of the study. No written consent will be requested, but parents have the option of opting out. Each patient will have a 5 minute Pocket echocardiography system scan followed by a full echo performed on a traditional full featured echo system. The objective is to assess if the current Food and Drug administration (FDA) approved Pocket echocardiography system (PES) can detect patent ductus arteriosus (PDA) in neonates as comparable to traditional full featured echo systems (FFES) and/or physical exam alone.
详细描述
All newborns admitted to the neonatal intensive care unit with orders for a cardiac echo evaluation will be included in this study. Parents will be approached and provided a description of the study. No written consent will be requested, but parents have the option of opting out. If parents agree to be part of this study, a 5-minute PES scan will be performed first so as to not bias the sonographer. Then, a full echocardiogram study will be performed on a traditional FFES. The scans will be performed at the bedside. The images will be reviewed and compared by fellow and/or attending and by experienced sonographer. The scans will include short axis view, ductal view and arch view.
The objective of the study is to assess if the current FDA approved PES can detect PDA in neonates as comparable to traditional full featured echo systems and/or physical exam alone. Using PES for PDA diagnosis will be an accessible, economic and effective way of complementing the findings in our physical exam by increasing diagnostic accuracy, and detecting PDA's at the bedside comparable to a full size traditional echocardiographic system.
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 盲法
- None
入排标准
- 年龄范围
- 1 Day 至 90 Days(Child)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •All newborn infants with orders for cardiac echocardiography evaluation in clinically stable condition
排除标准
- •Known congenital heart disease.
- •Clinically unstable (Meaning by unstable patients: Those patients that need cardiopulmonary resuscitation, or in maximum ventilatory or inotrope support and in immediate need for Extracorporeal Membrane Oxygenation or major surgery or whenever the physician attending responsible for the clinical care of the patient considers that a traditional echo needs to be done urgently)
结局指标
主要结局
False Positives Results of Pocket Echocardiography System (PES) Detection of Patent Ductus Arteriosus (PDA) to Full Featured Echo System (FFES)
时间窗: at baseline
Evaluate the usefulness of the currently FDA approved Pocket Echocardiography System (PES) in PDA detection as compared to Full Featured Echo System (FFES) by looking at false positives between the two systems.
False Negative Results of Pocket Echocardiography System (PES) Detection of Patent Ductus Arteriosus (PDA) to Full Featured Echo System (FFES)
时间窗: at baseline
Evaluate the usefulness of the currently FDA approved Pocket Echocardiography System (PES) in PDA detection as compared to Full Featured Echo System (FFES) by looking at false negatives between the two systems.
次要结局
未报告次要终点
