跳至主要内容
临床试验/NCT07276854
NCT07276854
尚未招募
不适用

Study of a Novel Near-Infrared (NIR) Fluorescent Molecular Probe Based on Humanized Ferritin for the Identification of Benign and Malignant Margins in Gastric Tissue

Nanfang Hospital, Southern Medical University1 个研究点 分布在 1 个国家目标入组 32 人开始时间: 2025年12月30日最近更新:

概览

阶段
不适用
状态
尚未招募
入组人数
32
试验地点
1
主要终点
The area under the curve (AUC) value of FTn-ICG for diagnostic performance

概览

简要总结

Radical surgery remains the primary treatment for gastric cancer, but intraoperative tumor margin assessment relies on surgeons' visual inspection, limiting accuracy. There is thus an urgent clinical need for real-time visualisation of tumour margins.

In recent years, near-infrared (NIR) fluorescence imaging has emerged as a critical tool for precision tumor resection. However, existing probes like indocyanine green (ICG) lack tumor-targeting specificity. Ferritin (FTn), with its unique nanocage structure, excellent biosafety, and well-defined in vivo behavior, presents an attractive platform for targeted molecular probes.

Yet, translational challenges persist, including animal model limitations and clinical validation bottlenecks. To address this, our study employs freshly resected human gastric tissue in an ex vivo perfusion system, simulating the circulatory dynamics of the humanized ferritin-based probe FTn-ICG in vivo. Using a prospective clinical sample cohort, we aim to validate its diagnostic efficacy in delineating gastric cancer margins, ultimately overcoming the critical barrier of precise tumor boundary identification.

研究设计

研究类型
Observational
观察模型
Case Only
时间视角
Prospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Pathologically or cytologically confirmed gastric or gastroesophageal junction adenocarcinoma eligible for radical resection, with histologically verified predominant adenocarcinoma component; Age ≥ 18 years; No gender restriction ; Voluntary participation with written informed consent.

排除标准

  • Patients who have received neoadjuvant therapy; Patients deemed ineligible for participation by the investigator's assessment.

结局指标

主要结局

The area under the curve (AUC) value of FTn-ICG for diagnostic performance

时间窗: 2 years

Pathologists performed histopathological examination of the tumors, while researchers compared the margins identified by pathological results with those predicted by the fluorescence imaging of the probe to calculate the AUC value of ICG-FTn.

次要结局

  • Expression of the TfR1 in the tumor(2 years)
  • FTn-ICG distribution in the tumor region(2 years)
  • Incidence rates of all adverse events (AEs)(2 years)

研究者

申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验