MedPath

Exploring an Alternative Pre-operative SLN Mapping Method Using a Magnetic Tracer and MRI for Melanoma Patients

Not Applicable
Recruiting
Conditions
Melanoma
Registration Number
NCT05145829
Lead Sponsor
Zuyderland Medisch Centrum
Brief Summary

Sentinel lymph node biopsy (SLNB) is crucial in the management of malignant melanoma treatment and is currently performed by pre-operatively inject a colloid nanomaterial labeled with Technetium (99mTc) as radioactive tracer. Intra-operatively, Patent Blue (PB) will be injected to improve the visualization of the lymphatic tract. However, current pre-operative SLN mapping technique is associated with disadvantages as radiation exposure for both patients and health care staff and logistic challenges, because of time constraints due to short half-live time of 99mTc.

Superparamagnetic iron oxide (SPIO) is a non-radioactive technique using a magnetic tracer (Magtrace® (Endomagnetics Ltd.)) to identify SLNs. Several studies showed that SPIO is non-inferior to dual tracing with 99mTc and PB in breast cancer patients. SPIO is expected to be non-inferior to dual tracing with 99mTc and PB in melanoma patients. However, further research is needed to demonstrate the use of SPIO in pre-operative MRI scanning.

The primary objective of this study is to evaluate the feasibility and diagnostic accuracy of pre-operative MRI scanning using SPIO compared to lymphoscintigraphy (LS) and single-photon emission computed tomography/computed tomography (SPECT/CT) using 99mTc for identifying SLN status in melanoma patients.

Detailed Description

Rationale: Sentinel lymph node biopsy (SLNB) is crucial in the management of malignant melanoma treatment and is currently performed by pre-operatively inject a colloid nanomaterial labeled with Technetium (99mTc) as radioactive tracer. Intra-operatively, Patent Blue (PB) will be injected to improve the visualization of the lymphatic tract. However, current pre-operative SLN mapping technique is associated with disadvantages as radiation exposure for both patients and health care staff and logistic challenges, because of time constraints due to short half-live time of 99mTc.

Superparamagnetic iron oxide (SPIO) is a non-radioactive technique using a magnetic tracer (Magtrace® (Endomagnetics Ltd.)) to identify SLNs. Several studies showed that SPIO is non-inferior to dual tracing with 99mTc and PB in breast cancer patients. SPIO is expected to be non-inferior to dual tracing with 99mTc and PB in melanoma patients. However, further research is needed to demonstrate the use of SPIO in pre-operative MRI scanning.

Objective: The primary objective of this study is to evaluate the feasibility and diagnostic accuracy of pre-operative MRI scanning using SPIO compared to lymphoscintigraphy (LS) and single-photon emission computed tomography/computed tomography (SPECT/CT) using 99mTc for identifying SLN status in melanoma patients. A secondary objective is to assess the feasibility and diagnostic accuracy of SPIO/magnetometer (Sentimag®, Endomagnetics Ltd.) in comparison with dual trace gold standard (99mTc and PB) in SLN procedures in melanoma patients.

Study design: A prospective single-arm feasibility study will be performed at the department of Surgical oncology at Zuyderland Medical Center Sittard, the Netherlands.

Study population: Adult patients (≥18 years) with primary melanoma stage I-II and an indication for wide local excision (1 cm) and SLN procedure will be included in the study.

Intervention (if applicable): All patients will undergo lymphatic mapping with a SPIO tracer (Magtrace®), 99mTc and PB.

Main study parameters/endpoints: The concordance in SLN detection rate (sensitivity and specificity) of SPIO/MRI and LS and SPECT/CT using 99mTc.

The concordance in SLN detection rate (sensitivity and specificity) of SPIO/magnetometer and the gold standard dual trace technique using 99mTc/Gamma probe and PB. Additionally, the number of post-injection (skin) reactions, complication and adverse events will be noted.

Recruitment & Eligibility

Status
RECRUITING
Sex
All
Target Recruitment
40
Inclusion Criteria
  • Patients ≥18 years of age at the time of consent;
  • Histological confirmed melanoma (patient must have primary cutaneous melanoma with Breslow thickness ≥ 0.8-2.0mm with or without ulceration or <0.8mm with ulceration (pT1b - pT2b, AJCC 8th edition));
  • Indication for wide local excision (margin 1 cm) and SLN procedure;
  • Patients should be willing and able to provide informed consent.
Exclusion Criteria
  • Intolerance/hypersensitivity to 99mTc-nanocolloid, PB, iron or dextran compounds;
  • Iron overload disease;
  • Pregnant or breast-feeding women;
  • Previous surrounded lymph node surgery;
  • Patients with head and neck melanomas;
  • Standard MRI exclusion criteria;
  • Implantable (electrical) devices (e.g. pacemaker, cochlear implants, neurostimulator);
  • Any other metal implants;
  • Claustrophobia;
  • MR-incompatible prosthetic heart valves;
  • Patients who are unable or refuse to provide informed consent.

Study & Design

Study Type
INTERVENTIONAL
Study Design
SINGLE_GROUP
Primary Outcome Measures
NameTimeMethod
The diagnostic accuracy of SPIO/MRI and LS+SPECT/CT and 99mTc to identify SLNBefore surgery (MRI scanning and scintigraphy)

The diagnostic accuracy of SPIO/MRI and LS+SPECT/CT and 99mTc to identify SLN will be expressed as sensitivity and specificity, and positive and negative predictive values, including their 95% exact binomial confidence intervals. MRI image analyses will be performed by two independent professionals.

Secondary Outcome Measures
NameTimeMethod
The diagnostic accuracy of SPIO/magnetometer and PB, 99mTc and Gamma probeDuring SLNB (surgery)

The diagnostic accuracy of SPIO/magnetometer and PB, 99mTc and Gamma probe will be expressed as sensitivity and specificity, and positive and negative predictive values, including their 95% exact binomial confidence intervals .

Number of post-injection (skin) reactions, complication and adverse eventsAt 10-14 days and at 3 months after the procedure

Descriptive only

Comparison between 99mTc injection + LS + SPECT/CT time vs SPIO injection + MRIDuring SLNB (surgery)

Time/duration of 99mTc injection + LS + SPECT/CT and time/duration of SPIO injection + MRI will be compared

Trial Locations

Locations (1)

Zuyderland Medical Center

🇳🇱

Sittard, Limburg, Netherlands

© Copyright 2025. All Rights Reserved by MedPath