Clinical Trial Investigating the BeGraft Peripheral Plus Stent Graft System for Iliac Lesion Treatment

Not Applicable
Active, not recruiting
Conditions
Peripheral Arterial Disease
Interventions
Device: BeGraft Peripheral Plus Stent Graft System
Registration Number
NCT03286361
Lead Sponsor
ID3 Medical
Brief Summary

The BeGraft Plus PMCF Trial investigates the efficacy of the BeGraft Peripheral Plus Stent Graft System in the treatment of iliac stenotic or occlusive lesions (TASC A, B, C and D). An expected total of 20 patients with TASC A and B lesions and an expected total of 50 patients with TASC C and D lesions will be treated. The lesion is located within the native Iliac arteries. Prior to stenting with the BeGraft Peripheral Plus Stent Graft System, pre-dilatation can be performed according to the physician's discretion. Also post-dilatation can be performed according to the physician's discretion. Patients will be invited for a follow-up visit at 1, 6, 12, 24 and 36- month post-procedure. The primary efficacy endpoint of the study is the primary patency at 12 months. The primary safety endpoint is the freedom of periprocedural Serious Adverse Events (SAEs). Secondary endpoint include primary patency rate at 1, 6, 24, and 36-month, stent graft occlusion rate at pre-discharge,1, 6, 24, and 36 month follow-up, anke-brachial index (ABI) at 1, 6, 12, 24 and 36-month follow-up, amputation rate at 1, 6, 12, 24 and 36-month follow-up, performance success rate, freedom from target lesion revascularization (TLR), technical success and clinical success at 1, 6, 12, 24 and 36-month follow-up. The extension in the Begraft Plus protocol is being made to evaluate the long-term safety and efficacy of the BeGraft Peripheral Plus Stent Graft.

Detailed Description

The objective of this clinical investigation is to evaluate, in a controlled setting, the long-term safety and efficacy of the BeGraft Peripheral Plus Stent Graft System in clinical settings post CE-certification when used according to the indications of the IFU with focus on the treatment of complex TASC A, B, C and D iliac lesions.

Patients will be selected based on the investigator's assessment, evaluation of the underlying disease and the eligibility criteria. The patient's medical condition should be stable, with no underlying medical condition which would prevent them from performing the required testing or from completing the study. Patients should also be geographically stable, willing and able to cooperate in this clinical study and remain available for long-term follow-up. A patient is considered enrolled in the study after obtaining the patients informed consent, if there is full compliance with the study eligibility criteria and after successful guidewire passage through the study target lesion.

Prior to the index procedure the following tests and clinical data will be collected: informed consent for data collection, demographics, medical history, medication record, physical examination, clinical category of chronic limb ischemia (Rutherford category) and resting ankle-brachial index (ABI).

During the procedure, the vascular access can be achieved to the investigator's standard clinical practice. After successful lesion passage, diagnostic angiography of the lesion area and distal run-off is performed and angiographic measurements (vessel diameter, percentage stenosis and lesion length) are collected. At the physician's discretion, the patient receives at least 1 BeGraft Peripheral Plus Stent Graft System. Pre- and post-dilatation are according to the physician's discretion. No other adjunctive therapies (atherectomy, laser) are allowed. The complete iliac vasculature should be treated in one single session, staged interventions are not allowed. All outflow-limiting lesions must be treated according to the hospital treatment standard.

The regular follow-ups are necessary to monitor the condition of the patient and the stent/procedure. Patients will be invited for a follow-up visit at 1, 6, 12, 24 and 36 months after the index procedure. The following data will be collected during these follow-up visit: medication record, physical examination, rutherford categorization, ABI and color flow doppler ultrasound.

Recruitment & Eligibility

Status
ACTIVE_NOT_RECRUITING
Sex
All
Target Recruitment
70
Inclusion Criteria

Not provided

Exclusion Criteria
  • PTA is technically not possible (not feasible to access the lesion or a defect with the guidewire or balloon catheter)

  • Presence of an aneurysm immediately adjacent to the site of stent implantation

  • Stenosis distal to the site of stent implantation

  • Lesions in or adjacent to essential collaterals(s)

  • Lesions in locations subject to external compression

  • Heavily calcified lesions resistant to percutaneous transluminal angioplasty (PTA)

  • Patients with diffuse distal disease resulting in poor stent outflow

  • Patients with a history of coagulation disorders

  • Patients with aspirin allergy or bleeding complications and patients unable or unwilling to tolerate anticoagulant/antiplatelet therapy and/or non-responders to anticoagulant/antiplatelet therapy

  • Fresh thrombus formation

  • Patients with known hypersensitivity to the stent material (L605) and or polytetrafluoroethylene (PTFE)

  • Previously implanted stent(s) at the same lesion site

  • Reference segment diameter is not suitable for the available stent design

  • Untreatable lesion located at the distal outflow arteries

  • Use of alternative therapy (e.g. atherectomy, cutting balloon, drug-coated balloon (DCB), laser, radiation therapy) as part of the index procedure

  • Patients refusing treatment

  • Patients for whom antiplatelet therapy, anticoagulants or thrombolytic drugs are contraindicated

  • Patients who exhibit persistent acute intraluminal thrombus of the proposed lesion site

  • Patients with a history of prior life-threatening contrast medium reaction

  • Patients with uncorrected bleeding disorders

  • Female patient with child bearing potential not taking adequate contraceptives or currently breastfeeding

  • Life expectancy of less than twelve months

  • Any planned surgical intervention/procedure within 30 days of the study procedure

  • Any patient considered to be hemodynamically unstable at onset of procedure

  • Patient is currently participating in another investigational drug or device study that has not completed the entire follow up period.

  • The target lesion is either a modified TASC-II class B, C or D lesion with aortic or common femoral lesion involvement:

    o Type B lesions

  • Short (≤3 cm) stenosis of infrarenal aorta

    o Type C lesions

  • Unilateral External Iliac Artery stenosis extending into the Common Femoral Artery

  • Unilateral External Iliac Artery occlusion that involves the origins of the Internal Iliac and/or Common Femoral Artery

  • Heavily calcified unilateral External Iliac Artery occlusion with or without involvement of origins of the Internal Iliac and/or Common Femoral Artery

    o Type D lesions

  • Infra-renal aortoiliac occlusion

  • Iliac stenoses in patients with an Abdominal Aortic Aneurysm (AAA) requiring treatment and not amenable to endograft placement or other lesions requiring open aortic or iliac surgery

  • Diffuse multiple stenoses involving the unilateral Common Iliac, External Iliac and Common Femoral Artery

Study & Design

Study Type
INTERVENTIONAL
Study Design
SINGLE_GROUP
Arm && Interventions
GroupInterventionDescription
BeGraft Peripheral + Stent Graft SystemBeGraft Peripheral Plus Stent Graft SystemPatients treated with the BeGraft Peripheral Plus Stent Graft System
Primary Outcome Measures
NameTimeMethod
Primary patency at 12 months12 months

Freedom from \>50% restenosis as indicated by an independently verified duplex ultrasound peak systolic velocity ratio (PSVR) \<2.5 in the target vessel with no target lesion revascularization within 12 months.

Periprocedural Serious Adverse Events (SAEs)30-days post-procedure

Periprocedural SAEs up to 30-days post-procedure, as defined according to the International Organization of Standardization (ISO) guidelines: ISO 14155:2011

Secondary Outcome Measures
NameTimeMethod
Primary patency rate1-, 6-, 24- and 36-months post-procedure

Freedom from \>50% restenosis as indicated by an independently verified duplex ultrasound peak systolic velocity ratio (PSVR) \<2.5 in the target vessel with no target lesion revascularization within 12 months.

Stent graft occlusion ratePre-discharge, 1-, 6- 12-, 24-, and 36-month follow-up

Occlusion of the stent graft system

Ankle-brachial index (ABI)1-, 6-, 12-, 24-, and 36-month follow-up

ABI at follow-up compared with the baseline ABI

Amputation rate1-, 6-, 12-, 24-, and 36-month follow-up

Any amputation above the knee

Performance success rateBaseline

Successful in sealing acute perforation or rupture, in treating aneurysms and fistulae of restoration of blood flow

Freedom from target lesion revascularization (TLR)1-, 6-, 12-, 24-, and 36-month follow-up

Freedom from a repeated intervention to maintain or re-establish patency within the region of the treated arterial vessel plus 5mm proximal and distal to the treated lesion edge

Technical successIndex procedure

Ability to achieve final residual angiographic stenosis no greater than 30%

Clinical success1-, 6-, 12-, 24-, and 36-month follow-up

Improvement of Rutherford classification compared to the pre-procedure Rutherford classification

Trial Locations

Locations (9)

az Groeninge

🇧🇪

Kortrijk, Belgium

Imelda Hospital

🇧🇪

Bonheiden, Belgium

RZ Heilig Hart

🇧🇪

Tienen, Belgium

ZOL

🇧🇪

Genk, Belgium

O.L.V. Hospital

🇧🇪

Aalst, Belgium

ZNA

🇧🇪

Antwerpen, Belgium

CHU de Nantes

🇫🇷

Nantes, France

A.Z. Sint-Blasius

🇧🇪

Dendermonde, Belgium

AZ Jan Portaels

🇧🇪

Vilvoorde, Belgium