跳至主要内容
临床试验/NCT05805189
NCT05805189进行中(未招募)不适用

Prospective Evaluation of Biophysical Parameters as Long-term Predictors of PVI With Multi-Electrode Radiofrequency Catheter: Comparison Between CARTO Guided and Fluoroscopy Guided Approach (MERCY Study)

Maria Cecilia Hospital2 个研究点 分布在 1 个国家目标入组 60 人开始时间: 2023年2月9日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
进行中(未招募)
发起方
入组人数
60
试验地点
2
主要终点
Pulmonary vein single shot isolation

研究概览

简要总结

Current, worldwide assessments of the prevalence of AF estimate that 33 million people are affected by this cardiac arrhythmia. As the most common sustained atrial arrhythmia, AF has a well-established association with systemic embolic events, stroke, heart failure, and increased mortality. Current treatment guidelines and consensus statements for patients with AF suggest that most patients should be first managed with a pharmaceutical drug therapy; however, when a patient becomes drug refractory (intolerant or non-responsive), catheter ablation by PV isolation (PVI) is recommended.

The aim of PVI is abolishment of all conducted electrical activity beyond the isolating lesions.

The recent NICE guidelines have established that today RF point-by-point ablation is the most cost-effective treatment approach over a lifetime after failure of 1 or more anti-arrhythmic drugs5, but until now a new technology, HELIOSTAR, RF Balloon, has not been included in this cost-effectiveness analysis

详细描述

The multi-electrode RF Balloon catheter (HELIOSTAR, Biosense Webster) is a compliant Balloon with 10 circularly orientated electrodes bonded to its surface. It has been designed to be used in conjunction with the Carto3 system (Biosense Webster, CA). It is able to deliver RF energy directly forming a continuous circular ablation lesion around the PV ostia. With HELIOSTAR, each individual electrode can sense temperature and can be controlled separately. The electrodes can be used for visualization, stimulation, recording and ablation. The compliance of the Balloon allows conformation to the anatomy of the PVs and therefore maximizing tissue contact. The advantages of the RF Balloon include the ease of use to the operator that is associated with Balloon delivery systems, possibility of single shot PVI with tailored RF energy delivery, potentially shorter procedure times and avoidance of collateral damage to non-PVI structures, due to the capacity to individually select and deselect electrodes during ablation.6,7 To date, retrospective analyzes conducted in the RADIANCE and SHINE studies have shown the pre-ablation indicators of optimal electrode positioning and post-RF indicators associated with better outcomes; specifically, baseline impedance range 90-110 Ohms, impedance variability across ten electrodes ≤20 Ohms, baseline electrode temperature ≤31°C, baseline temperature variability ≤3°C and the post-RF indicators (impedance drop ≥12 Ohm and temperature rise ≥6°C) seem to independently predict a durable PVI. To the best of our knowledge, no studies have investigated prospectively the performance of impedance drop and temperature rise of HELIOSTAR ablation in terms of feasibility, acute PVI and post-procedural outcomes.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Sequential
主要目的
Treatment
盲法
Single (Participant)

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • The following criteria must be met for subjects to be eligible for inclusion into the study
  • Subjects indicated for the treatment of paroxysmal AF with the RF ablation system according to current and future Guidelines and system indications for use
  • Subjects who are willing and capable of providing informed consent
  • Patients who have stopped amiodarone for at least one month
  • Subjects whose age is > 18 years old
  • Subjects whose age is < 80 years old
  • Subjects who are willing and capable of participating in all testing associated with this clinical study at an approved clinical investigational center

排除标准

  • Subjects who meet any one of the following criteria will be excluded from this clinical study
  • Patients who had already undergo an AF ablation procedure
  • Any known contraindication to an AF ablation or anticoagulation, including those listed in the instructions for use
  • Subjects with indication for treatment of AF that is not according to current and future Guidelines and system indications for use
  • Presence of an intracavitary thrombus
  • Subjects that are unable or not willing to complete follow-up visits and examination for the duration of the study
  • Patients with left ventricular ejection fraction < 35%
  • Women of childbearing potential who are, or plan to become, pregnant during the time of the study (method of assessment upon investigator's discretion)
  • Hematological contraindications to ionizing radiation exposure
  • Presence of complex congenital heart disease, and cardiac surgery within 1 month from enrollment
  • Uncontrolled heart failure
  • Subjects with severe valvular disease OR with a prosthetic - mechanical or biological- heart valve (not including valve repair and annular rings)
  • Contraindications to general anesthesia
  • Subjects who are currently enrolled in another investigational study or registry that would directly interfere with the current study

研究组 & 干预措施

Heliostar group A

Experimental

In this group the achievement of isolation of the pulmonary veins is evaluated with one shot tecnology Heliostar, multielecrode radiofrequency ballon catheter guided by the impedance level measured in the veins

干预措施: pulmonary vein (PV) isolation (Procedure)

Carto Group B

Active Comparator

In this group the achievement of isolation of the pulmonary veins is evaluated with classic method guided by fluoroscopy

干预措施: pulmonary vein (PV) isolation (Procedure)

结局指标

主要结局

Pulmonary vein single shot isolation

时间窗: 12 months

The primary objective of this study is PV single shot isolation in acute and at 1-3-6-12 months follow up with stringent monitoring including medical examination (Echo, ECG, and 24h-Holter).. It will be assessed the time necessary to reach the isolation, the number of erogations, the fluoroscopy dose and any use of contrast medium and they will be compared between the two arms. Our aim is to demonstrate that, even in the case of equivalent relapse rates during the follow up, the CARTO guided approach allows patients to benefit from a faster and less invasive procedure compared to the fluoroscopy guided method. This occurs because the former doesn't require contrast medium and the fluoroscopy time is notably reduced.

次要结局

  • Correlation of biophysical parameters, procedural, and ablation times(12 months)

研究者

发起方
Maria Cecilia Hospital
申办方类型
Other
责任方
Sponsor

研究点 (2)

Loading locations...