Impedance Cardiography in the Evaluation of Left Ventricular Diastolic Dysfunction in Patients With Arterial Hypertension Study (IMPEDDANS)
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- 入组人数
- 154
- 试验地点
- 3
- 主要终点
- Predictive value of impedance cardiography to identify diastolic dysfunction
研究概览
简要总结
Arterial hypertension (AHT) is responsible for important morbidity and mortality. The cardiac repercussion of AHT is usually assessed by electrocardiography and echocardiography, time-consuming, technically demanding examinations that require experienced operators, which limits their use for screening diastolic dysfunction. Alternative tools for the screening of diastolic function in hypertensive patients are needed. Impedance cardiography (IC) is presently used in the study of AHT and in the optimization of antihypertensive therapy. It seems an attractive and economical option to change the clinical approach for screening; however, its validation in well-defined populations is required to sustain its use in clinical practice. The IMPEDDANS study aims to validate IC for screening left ventricular diastolic dysfunction in outclinic patients with AHT, using functional echocardiography as the clinical standard. Descriptive and analytical study with analysis of the agreement between the diagnosis of diastolic dysfunction and its degree, as well as the parameters obtained by impedance cardiography and echocardiography in patients with AHT.
详细描述
BACKGROUND. Impedance cardiography (IC) is a complementary diagnostic test used in the study of arterial hypertension (AHT) and in the optimization of antihypertensive therapy. It is easy-to-execute, non-operator-dependent and cost-effective. It analyses and registers hemodynamic changes through the measurement of electrical resistance changes in the thorax and translates them graphically as impedance and electrocardiogram waveforms. IC has evolved in recent years, making it an attractive and economical tool, particularly in screening settings and there is extensive published literature on its usefulness. More widespread use of IC has been limited due to limitations of the studies, mostly cross-sectional, with small samples, recruiting hemodynamically stable patients and providing inconsistent estimates of accuracy and reproducibility in different settings.
AHT is responsible for high morbidity and mortality. In Portugal, according to PHYSA study, has overall prevalence of hypertension, in 2014, of 42.2% (44.4% in men, 40.2% in women). The progression of hypertensive heart disease involves myocardial fibrosis and changes in left ventricular geometry that precedes functional changes. Diastolic dysfunction is part of this continuum, and despite the growing recognition of its importance, it is generally undervalued because of the difficulty in its diagnosis and the absence of effective therapies. This reinforces the importance of finding alternative tests that provide important information for an initial assessment of diastolic function in hypertensive patients.
This study intends to define the importance and usefulness of IC in the evaluation of LV diastolic dysfunction in patients with AHT.
METHODS. Study Design. This is a validation study of a diagnostic method used in a new context, comparing it with the diagnostic method currently used for this effect in usual clinical practice. Its purpose is to determine the positive predictive value, negative predictive value, sensitivity and specificity of the presence of the D wave, the isovolumetric relaxation time, the systolic time ratio (STR) and thoracic fluid content (TFC) by IC, for the diagnosis of LV diastolic dysfunction (LVDD). To study the relationship between LV geometry, hemodynamic profile, diastolic dysfunction and its degree (confirmed by echocardiography) in hypertensive patients with diastolic dysfunction. We chose to perform a concordance study between IC and echocardiography, the validated , non-invasive test used for the clinical diagnosis of LVDD as well as for the characterization of hypertensive cardiopathy.
To calculate the sample size we considered the primary endpoint (concordance of the diagnosis of diastolic dysfunction between IC and echocardiography). Thus, considering a hypothesized positive predictive value of 70 ± 5% of the parameters obtained by IC, 77 individuals are estimated to be able to verify the expected positive predictive value with 95% confidence. Since the prevalence of diastolic dysfunction in patients with AHT estimated to be approximately 50% in most studies, the sample size is doubled for 154 hypertensive patients.
研究设计
- 研究类型
- Observational
- 观察模型
- Case Control
- 时间视角
- Cross Sectional
入排标准
- 年龄范围
- 18 Years 至 75 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •grade 2 or 3 hypertension (systolic blood pressure ≥ 160 mmHg and/or with diastolic blood pressure values ≥ 100 mmHg) and/or with resistant hypertension (as defined by European Society of Cardiology
排除标准
- •pregnancy,
- •height less than 120 cm or more than 230 cm,
- •weight less than 30 kg or greater than 155 kg,
- •heart failure II-IV NYHA,
- •heart rate (HR) less than 50 bpm or greater than 110 bpm,
- •atrial fibrillation or flutter,
- •> 3 premature ventricular contractions per hour,
- •complete left bundle branch or atrioventricular block,
- •severe valvulopathies,
- •constrictive pericarditis,
- •hypertrophic and restrictive cardiomyopathy,
- •prior history of ischemic heart disease and/or segmental kinetics alterations assessed by echocardiography,
- •left ejection fraction < 50%,
- •poor echocardiographic window ,
- •pacemaker.
结局指标
主要结局
Predictive value of impedance cardiography to identify diastolic dysfunction
时间窗: Less than 10 days between measurements
Positive predictive value of impedance cardiography to identify diastolic dysfunction, compared with echocardiography
Area under the curve (AUC)
时间窗: Less than 10 days between measurements
The area under the receiver-operator curves (ROC) for identification of diastolic dysfunction by impedance cardiography, compared with echocardiography
次要结局
- Negative predictive value of impedance cardiography to identify diastolic dysfunction(Less than 10 days between measurements)