跳至主要内容
临床试验/NCT03605160
NCT03605160Unknown不适用

Efficacy of Fluid-jet as an Innovative Method to Prevent Posterior Capsular Opacity After Phacoemulsification

Sun Yat-sen University1 个研究点 分布在 1 个国家目标入组 740 人开始时间: 2018年1月1日最近更新:
适应症
干预措施

试验速览

阶段
不适用
发起方
入组人数
740
试验地点
1
主要终点
change in rate of posterior capsulotomy

研究概览

简要总结

Residual lens fibers (RLFs) on the posterior lens capsule during cataract surgery can cause after cataract, affecting visual quality and increasing the medical cost for further laser posterior capsulotomy. However, conventional polish is inconvenient and time-consuming. We use an innovative fluid-jet method to remove RLFs, and compare the efficacy of fluid-jet and polish to prevent posterior capsular opacity after phacoemulsification.

详细描述

Purpose: Residual lens fibers (RLFs) on the posterior lens capsule during cataract surgery can cause after cataract, affecting visual quality and increasing the medical cost for further laser posterior capsulotomy. However, conventional polish is inconvenient and time-consuming. We use an innovative fluid-jet method to remove RLFs, and compare the efficacy of fluid-jet and polish to prevent posterior capsular opacity after phacoemulsification.

Design: Single-center, prospective, randomized controlled clinical study Subjects of study: Age-related cataract patients receiving phacoemulsification from Zhongshan Ophthalmic Center, Guangzhou, China.

Methods: patients are 1: 1 randomized to two groups. Polish group: After irrigation and aspiration (I/A), the RLFs on the posterior capsule are removed by polishing before intraocular lens (IOL) implantation; Fluid-jet group: Polish is not performed. RLFs on posterior capsule are removed by jetting fluid with an irrigating syringe after IOL implantation. The posterior capsular images of all the patients are obtained immediately before and after IOL implantation, and at the end of surgery, then the amount of RLFs is quantitatively analyzed by using LYZ-PCO, a software we developed. Best corrected visual acuity and parameters of visual quality, such as objective scattering index(OSI), Strehl ratio (SR) and Modulation Transfer Function (Mtf)-cut off are evaluated by objective visual quality analyser (OQAS) at 1 day, 1 week and 1 year after surgery. The patients receives telephone follow-up every month. The severity of posterior capsular opacification (PCO) and incidence of laser posterior capsulotomy is recorded.

Main indicators for the study: The incidence of laser posterior capsulotomy a year after surgery.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Prevention
盲法
Double (Care Provider, Outcomes Assessor)

入排标准

年龄范围
50 Years 至 80 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Iinclusion criteria:
  • cataract patients aged between 50 and 80 years; 2) graded 5 or less for lens opalescence by the Lens Opacities Classification System, version III (LOCS III); 3) listed for phacoemulsification combined with intraocular lens implantation in topical anesthesia; 4) Signed informed consent.

排除标准

  • a history ophthalmic trauma or surgery; 2) other ophthalmic diseases such as glaucoma, uveitis, high myopia; 3) diabetes requiring medical control; 4) disagree with follow-up monitoring; 5) Other factors inappropriate to participate in this project, including but not limited to severe cataracts, very shallow anterior chambers, etc.

研究组 & 干预措施

traditional group

Active Comparator

Perform conventional continuous curvilinear capsulorhexis. After phacoemulsification and I/A, switch to polish mode and use I/A instrument to remove the RLFs visible on the posterior capsule before injection of viscoelastic agent. IOP: 55mmHg; Aspiration: 0-10; Vacuum: 0-20. The standard for stopping polish is that the RLFs can no longer be absorbed by the side holes on the I/A instrument in this mode, or there are no discernible RLFs on the posterior capsule. If RLFs on the posterior capsular are found after IOL implantation, polish to remove them after the removal of viscoelastic agents. All operations are videotaped during the whole operation. The total polish time is recorded as the time of all polish procedures.

干预措施: traditional polish (Procedure)

fluid-jet group

Experimental

Perform conventional continuous curvilinear capsulorhexis. After phacoemulsification and I/A, inject viscoelastic agent and implant IOL without polish. Use I/A instrument to remove viscoelastic agent. A 27G irrigating syringe was used, and the RLFs on the posterior capsule were gently aligned to make a fluid-jet basically parallel to the iris. The liquid pressure of 50-120 mmHg is produced. The standard for stopping in this mode is that the RLFs can no longer be washed down from the capsule, or there are no discernible RLFs on the posterior capsule. All operations are videotaped during the whole operation. The total time of all jet procedures recorded in the videotape is the total time of jet.

干预措施: fluid-jet (Procedure)

结局指标

主要结局

change in rate of posterior capsulotomy

时间窗: 1 year, 2 year, 3 year, 4 year, 5 year after surgery

Incidence rate of laser posterior capsulotomy

次要结局

  • area of posterior capsular opacification(1 year, 2 year, 3 year, 4 year, 5 year after surgery)
  • change in objective scattering index(1 day, 1 week, 1 year post-op, and every year thereafter.)
  • change in visual acuity(1 day, 1 week, 1 year post-op, and every year thereafter.)
  • change in Strehl ratio(1 day, 1 week, 1 year post-op, and every year thereafter.)
  • change in modulation transfer function cut off(1 day, 1 week, 1 year post-op, and every year thereafter.)
  • residual lens fibers(the amount of residual lens fibers is to be measured for every participant using ocular image taken with surgical microscope at the end of the cataract surgery)

研究者

发起方
Sun Yat-sen University
申办方类型
Other
责任方
Principal Investigator
主要研究者

Haotian Lin

professor

Sun Yat-sen University

研究点 (1)

Loading locations...

相似试验