MedPath

Opsens Optowire for Fractional Flow Reserve - The O2 Pilot Study

Not Applicable
Completed
Conditions
Stable Angina
Unstable Angina Pectoris
Chest Pain
Ischemia
Interventions
Device: Fractional flow reserve measurement
Registration Number
NCT02144090
Lead Sponsor
Laval University
Brief Summary

The purpose of this study is to assess the usability and safety of the Opsens OptoWire and Optomonitor in measuring fractional flow reserve (FFR) in patients with coronary artery disease who are undergoing a coronary angiogram.

Detailed Description

Fractional flow reserve (FFR) measurement involves determining the ratio between the maximum achievable blood flow in a diseased coronary artery and the theoretical maximum flow in a normal coronary artery. An FFR of 1.0 is widely accepted as normal. An FFR value lower than 0.75 - 0.80 is generally considered to be associated with myocardial ischemia (MI).

FFR is easily measured during routine coronary angiography by using a pressure wire to calculate the ratio between coronary pressure distal to a coronary artery stenosis and aortic pressure under conditions of maximum myocardial hyperemia. This ratio represents the potential decrease in coronary flow distal to the coronary stenosis.

Over the past decade, FFR measurement has been increasingly used in cardiac catheterization laboratories. It provides a quantitative assessment of the functional severity of a coronary artery stenosis identified during coronary angiography and cardiac catheterization.

Opsens, Inc. has developed a new pressure wire for use in determining FFR in coronary arteries; the OptoWire. The OptoWire is an instrumented guide wire with a fiber optic pressure sensor mounted 3.5 cm proximal to the tip. The Optowire measures blood pressure during diagnostic and/or interventional procedures when used in combination with the OptoMonitor.

The O2 study is a pilot study which aims to provide preliminary experience in human patients with coronary artery disease. The study data will also be used as part of design validation.

The O2 study is a prospective single arm study designed to assess the usability, functionality, and safety of the Optowire and Optomonitor in patients.

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
60
Inclusion Criteria
  • Patients with

    • Stable angina or,
    • Unstable angina pectoris or,
    • Atypical chest pain or no chest pain but with suspected ischemia
  • At least one moderate lesion in native coronary artery thought to produce ischemia

  • Operator and patient agree for procedures

  • Patient (> 18 years) has signed a written informed consent prior to procedure

Exclusion Criteria
  • Lesions with angiographic 'haziness' or suspected to contain thrombus
  • Post-coronary artery bypass grafting
  • Total occlusion
  • If use of atherectomy device is indicated

Study & Design

Study Type
INTERVENTIONAL
Study Design
SINGLE_GROUP
Arm && Interventions
GroupInterventionDescription
Fractional flow reserveFractional flow reserve measurementFractional flow reserve measurement
Primary Outcome Measures
NameTimeMethod
Safety and handling assessment of the OptowirePatients will be followed through removal of the OptoWire from percutaneous insertion site and completion of the cardiac catheterization procedure (expected average <1hr)

1. Safely reach and cross a target lesion;

2. perform an FFR measurement using the Optowire and Optomonitor according to the product user guide;

3. disconnect the proximal connector on the OptoWire during the procedure, placing an interventional device (if necessary), and reconnecting the Optowire proximal connector;

4. safely remove the Optowire from the coronary artery.

Dedicated questionnaires will be used for such assessment

Secondary Outcome Measures
NameTimeMethod
Comparison of FFR values measured with Optowire vs. with FFR guide wire used in standard practicePatients will be followed through removal of the OptoWire from percutaneous insertion site and completion of the cardiac catheterization procedure (expected average <1hr)

In selected cases, the operator may choose to perform FFR measurements using currently approved FFR wires. Values obtained with standard FFR wires and Optowire may therefore be compared.

Trial Locations

Locations (1)

IUCPQ - Laval Hospital

🇨🇦

Quebec, Canada

© Copyright 2025. All Rights Reserved by MedPath