Effect of Bi-ventricular Pacing on Autonomous Nervous System
试验速览
- 阶段
- 不适用
研究概览
简要总结
Patients with congestive heart failure are often associated with delayed intraventricular depolarization which causing dyssynchrony and an inefficient pattern of left ventricular contraction. A number of studies have shown that bi-ventricular or left ventricular pacing improves indexes of systolic function as well as decreases sympathetic activation in patients with severe left ventricular systolic dysfunction, dilated cardiomyopathy and a major left-sided intraventricular conduction disorder such as left bundle branch block. One recent study also demonstrated that bi-ventricular pacing can shift heart rate variability (HRV) toward a more favorable profile. Baroreflex sensitivity (BRS) is a measure of the negative feedback properties that interact in modulating the dynamic heart rate and arterial pressure fluctuations. Blunted BRS is found to be associated with an increased risk for both cardiac deaths and arrhythmic events. However, the effect of bi-ventricular pacing on BRS has never been studied. In the present proposal, we plan to measure common hemodynamic parameters, BRS and HRV in a group of heart failure patients receiving open heart surgery in different pacing conditions (bi-ventricular pacing, single LV pacing, single RV pacing). The major aims are to investigate the effect of bi-ventricular pacing on BRS and to clarify the underlying mechanisms.
详细描述
Operation and lead placement:
Off-pump coronary artery bypass (OPCAB) is performed based on patient's coronary angiography. Following the completion of coronary anastomoses, epicardial pacemaker leads are implanted by simple stitches in different locations. The right atrial (RA) lead is placed on the right atrial appendage. The right ventricle (RV) lead is placed on the RV free wall near the apex. The left ventricle (LV) lead is placed on the lateral wall of LV at the border zone between diagonal and obtuse marginal branches of coronary artery. All three ground leads are placed on the rectus abdominis muscle. All these leads are pulled out of the patient percutaneously. Medtronic dual-chamber pacemaker is used for this study. The change of different pacing protocol (RV pacing, LV pacing, or biventricular pacing) is through the connection of different pacemaker leads.
Hemodynamic study:
All patients underwent OPCAB have Swan-Ganz catheter in our institute. Cardiac output measurement is obtained by thermodilution method. Hemodynamic variables (systemic blood pressure, pulmonary artery pressure, central venous pressure, pulmonary capillary wedge pressure, systemic vascular resistance, and pulmonary vascular resistance, etc) are recorded during the measurement.
ECG and blood pressure monitoring system:
研究设计
- 研究类型
- Interventional
- 分配方式
- Non Randomized
- 干预模型
- Single Group
- 主要目的
- Treatment
- 盲法
- None
入排标准
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Patients with normal sinus rhythm proposed to undergo coronary artery bypass surgery.
排除标准
- 未提供
