跳至主要内容
临床试验/NCT04049708
NCT04049708已完成不适用

Intrarater Reliability in Different Days and Interrater Reliability of Physical Function Assessment in HD Patients

Cardenal Herrera University1 个研究点 分布在 1 个国家目标入组 30 人开始时间: 2019年8月7日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
30
试验地点
1
主要终点
Change from baseline Short Physical Performance Battery at one week

研究概览

简要总结

The investigators will calculate values of absolute and relative reliability for intrarater reliability when the measures are taken during a hemodialysis treatment day and during a non-dialysis day. Interrater reliability between two different observers will be also calculated

详细描述

Patients suffering from End Stage Renal Disease are commonly involved in haemodialysis treatment, which is the most common treatment at this stage. Haemodialysis substitutes the renal function but is associated with several alterations that lead to decrease in functional capacity. Many studies show that functional capacity is significantly worse than their healthy sedentary age - matched counterparts. The purpose of the present study is to calculate values of absolute and relative intrarater reliability (dialysis vs non dialysis day) and interrater reliability of different physical function measures (Short Physical Performance Battery, one-leg balance, Timed Up and go, sit to stand to sit tests, triceps and handgrip strength, six-minute walking test).

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • At least 3 months in hemodialysis treatment
  • Clinically stable

排除标准

  • Recent cardiac events (less than 3 months)
  • Unable to exercise

结局指标

主要结局

Change from baseline Short Physical Performance Battery at one week

时间窗: It will perform the test three times with one week interval between the testing sessions, one before hemodialysis, and the other one next week during a non-dialysis day

Assess lower extremity, which includes objective performance-based measure of balance (side-by-side, semitandem and tandem), endurance (4m gait speed) and strength (five chair stands). Each component was scored from 0 to 4 and when summed yielded SPPB scores between 0 (poor) and 12 (best).

次要结局

  • Change from baseline Gait speed at one week at one week(It will perform the test three times with one week interval between the testing sessions, one before hemodialysis, and the other one next week during a non-dialysis day)
  • Change from baseline One-leg standing test at one week(It will perform the test three times with one week interval between the testing sessions, one before hemodialysis, and the other one next week during a non-dialysis day)
  • Change from baseline Sit to stand 10 test at one week(It will perform the test three times with one week interval between the testing sessions, one before hemodialysis, and the other one next week during a non-dialysis day)
  • Change from baseline Sit to stand 60 test at one week(It will perform the test three times with one week interval between the testing sessions, one before hemodialysis, and the other one next week during a non-dialysis day)
  • Change from baseline Timed up and go at one week(It will perform the test three times with one week interval between the testing sessions, one before hemodialysis, and the other one next week during a non-dialysis day)
  • Change from baseline One-leg heel rise test at one week(It will perform the test three times with one week interval between the testing sessions, one before hemodialysis, and the other one next week during a non-dialysis day)
  • Change from baseline 6 minutes walk test at one week(It will perform the test three times with one week interval between the testing sessions, one before hemodialysis, and the other one next week during a non-dialysis day)
  • Change from baseline Handgrip at one week(It will perform the test three times with one week interval between the testing sessions, one before hemodialysis, and the other one next week during a non-dialysis day)

研究者