A Prospective Evaluation of the Catheter Science C3 "Umbrella Catheter" for Patients With Urinary Retention Due to Bladder Dysfunction (C3 Catheter Study)
试验速览
- 阶段
- 不适用
- 发起方
- 入组人数
- 50
- 试验地点
- 2
- 主要终点
- The retreat of the C3 back into the bladder from the engaged position
研究概览
简要总结
The Catheter Science C3 "Umbrella Catheter" has been developed for management of urinary retention in patients who are either using a Foley or Self Intermittent Catheter. This device is inserted into the bladder in an extended state and once the stylet is removed the device folds into collapsed state. A thread is attached to the device and traverses thru the urethra and is attached to a bobber. With gentle traction on the thread the device engages the bladder neck and the central tube extends which allows for the flow of urine. Once voiding is complete, the thread is released and the device collapses back to the folded state into the bladder. Each voiding cycle is accomplished in a similar fashion. This is a novel technique in which the bladder is catheterized with the device from within the bladder into the bladder neck and urethra. The standard self catheter technique is for placement of a catheter from the outside into the urethra and into the bladder.
详细描述
Interventional (clinical trial): Participants are assigned prospectively to an intervention or interventions according to a protocol to evaluate the effect of the intervention(s) on biomedical or other health related outcomes.
This single arm, prospective study is designed to produce valid scientific evidence regarding:
- Safety and efficacy of the Catheter Science C3 "Umbrella Catheter" in establishing urinary drainage and allowing the control of micturition when indwelling for up to 7 days.
- The reduction in Catheter Acquired Urinary Tract Infection (CAUTI)
A single arm study design was chosen because there is no alternative treatment to serve as an appropriate control. The C3 catheterizes the bladder with engagement into the bladder neck under the control of the patient or care giver. A Foley catheter, a pre- amendment device, was considered for a control treatment. However, although a Foley catheter is used to establish urinary drainage with close to 100% efficacy, it does not restore voiding function like the C3, and severely impairs activities of daily life.
The intrinsic design flaws of a Foley catheter traversing thru the urinary passage which violates the anatomical protective points which help to avoid bacterial contamination. The distal 1/3 portion of the urethra in females is commonly colonized with bacteria. Standard Catheter technique traverses from the outside into the entire length of the urethra to drain the bladder. The standard self catheter flow characteristics are impacted due to the placements of the "eyes" to the catheter lumen. The C3 lumen is open in line with the flow.
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 主要目的
- Other
- 盲法
- None
入排标准
- 年龄范围
- 21 Years 至 —(Adult, Older Adult)
- 性别
- Female
- 接受健康志愿者
- 是
入选标准
- •Patients with Bladder Dysfunction requiring mechanical drainage.
- •Patients with actual urinary retention
排除标准
- •Inability to undergo bladder catheterization (e.g., urethral stricture or history of urethral stricture)
- •Gross hematuria
研究组 & 干预措施
C3 PATIENT PARTICIPANTS
This single arm prospective study is designed to produce valid scientific evidence regarding safety and efficacy of the C3 in establishing urinary drainage and allowing the control of micturition when indwelling for up to 7 days in patients. The total study population will initially include 50 subjects with open enrollment of additional subjects.
干预措施: C3 "UMBRELLA CATHETER" (Device)
结局指标
主要结局
The retreat of the C3 back into the bladder from the engaged position
时间窗: Measurement of data points are collected sequentially every 7 days up to 28 days.
The percentage of enrolled patients who upon completion of bladder drainage with the engaged tubular portion of the C3 in bladder neck and urethral location retreats back into the default position in the bladder.
Catheterization of the bladder from an antegrade direction with the C3 device.
时间窗: Measurement of data points are collected sequentially every 7 days up to 28 days.
The percentage for patients enrolled in the student with the C3 inserted who are able to engage the tubular portion of the device into the bladder neck and urethra from the default position in the bladder with resultant drainage of the bladdder.
次要结局
- Reduction in Catheter Acquired Urinary Tract Infection Rate(Measurement of data points are collected sequentially every 7 days up to 28 days.)
研究者
Dr. Gaines W. Hammond Jr. MD FACS
SPONSOR- INVESTIGATOR
Hammond, Gaines W., Jr., M.D. FACS