INJ-LIVERB-01 Identification of Liver Tumours Using BIP - Biopsy System

Injeq Ltd2 个研究点 分布在 1 个国家目标入组 26 人开始时间: 2016年6月9日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
26
试验地点
2
主要终点
Difference in mean between measured bioimpedance spectra from tumorous and nontumorous tissue

研究概览

简要总结

This clinical device investigation is conducted by performing liver biopsies using the BIP - Biopsy Tool. The aim is to assess the feasibility of bioimpedance spectroscopy based biopsy tool guidance method and test how well BIP biopsy system is able to distinguish liver tumours from surrounding tissue. In addition, user feedback is obtained to improve the usability of the investigational device. The study does not affect the traditional treatment procedure and only the patients in clinical need for diagnosis by liver biopsy are included on voluntary basis. The invasive products used in actual biopsy operation are designed so that their performance is essentially equal to the currently used biopsy devices, the only difference is the measurement capability of biopsy needle and connection to measurement device.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Other
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Consenting adults undergoing ultrasound-guided core liver biopsy to diagnose liver tumour or other abnormalities
  • Identifiable non-tumorous liver tissue along the planned needle injection path.

排除标准

  • Inability to give informed consent
  • Being under aged
  • Being pregnant
  • Being high risk patient
  • Lack of identifiable non-tumorous liver tissue along the injection path to the tumour location
  • Known contraindications to liver biopsy.

研究组 & 干预措施

BIP Biopsy System

Experimental

Biopsy system that enables real-time bioimpedance measurement from the tip of the biopsy needle.

干预措施: BIP Biopsy System (Device)

结局指标

主要结局

Difference in mean between measured bioimpedance spectra from tumorous and nontumorous tissue

时间窗: During liver biopsy (couple of minutes/patient)

Liver biopsy is performed in traditional way but with biopsy needle that enables bioimpedance measurement from multiple frequencies (spectrum). Tumorous and nontumorous tissue is measured during ultrasound guided biopsy procedure and the tumorous tissue type is verified by histological biopsy sample analysis. The bioimpedance spectra (impedance and phase angle) are compared with each other and differences in means of the spectra calculated. The data analysis is performed offline.