MedPath

Auditory Rehabilitation in Stroke Patients With Auditory Processing Disorders

Not Applicable
Completed
Conditions
Auditory Processing Disorder, Central
Stroke
Interventions
Other: personal frequency modulated systems
Registration Number
NCT02889107
Lead Sponsor
University College, London
Brief Summary

This study aimed to evaluate long term benefits in speech reception in noise, after daily 10 week use of an assisting listening device (personal frequency-modulates systems) , in non-aphasic stroke patients with auditory processing deficits.

Detailed Description

Stroke can affect all levels of the auditory pathway. Approximately one in five stroke survivors report severe difficulties when listening to speech-in-noise, despite normal hearing, attributed to abnormal processing of sounds within the brain, and these individuals are more likely to experience communication difficulties in poor acoustic environments, The patient with significant auditory deficits and functional limitations may require a range of rehabilitation and remediation approaches. Several studies conclusively demonstrate substantial improvements in speech recognition in noise when using personal frequency-modulated (FM) systems. These devices are used to improve speech perception in noise in adults with neurological disorders including stroke with good immediate benefits. However, the long-term benefits of FM systems in stroke patients has not been studies. In this research study the investigators aimed to investigate the long term benefits in speech reception in noise in non-aphasic stroke patients and measure the potential improvement in unaided speech in background noise performance after 10 weeks.

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
9
Inclusion Criteria
  • Clinical history of ischaemic stroke verified by brain magnetic resonance imaging (MRI)
  • Diagnosis of auditory processing disorders
  • Normal pure-tone audiogram
Exclusion Criteria
  • Severe aphasia
  • Significant psychiatric illnesses

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Arm && Interventions
GroupInterventionDescription
interventionpersonal frequency modulated systemsPatients received an assistive listening device (personal frequency modulated systems) for 10 weeks
Primary Outcome Measures
NameTimeMethod
The signal-to-noise ratio (SNR) benefit for speech in noise (reported in decibel, dB)week 1

Patients are tested in a sound attenuated booth (the crescent of sound) with nine audio stands, an equipment cabinet, and a testing station for the assessment of spatial-listening skills. A 'Speech in noise' test was used. In this test, recorded spoken sentences are presented from straight ahead (0°) while noise is also coming from 90° to the left or right from the participant, who is asked to repeat the sentence. The number of keywords successfully repeated is recorded and repetition of at least three keywords per sentence is required to judge correct performance. The level of the sentences and the background noise are adaptively varied to estimate the signal-to-noise ratio (SNR) for 50% correct performance. The test was conducted with the participant using the frequency modulated systems (aided condition) or not using the frequency modulated systems (unaided condition). The level of SNR is reported in dB.

Secondary Outcome Measures
NameTimeMethod
The signal-to-noise ratio (SNR) benefit for speech in noise (reported in decibel, dB)week 10

Patients are tested in a sound attenuated booth (the crescent of sound) with nine audio stands, an equipment cabinet, and a testing station for the assessment of spatial-listening skills. A 'Speech in noise' test was used. In this test, recorded spoken sentences are presented from straight ahead (0°) while noise is also coming from 90° to the left or right from the participant, who is asked to repeat the sentence. The number of keywords successfully repeated is recorded and repetition of at least three keywords per sentence is required to judge correct performance. The level of the sentences and the background noise are adaptively varied to estimate the signal-to-noise ratio (SNR) for 50% correct performance. The test was conducted with the participant using the frequency modulated systems (aided condition) or not using the frequency modulated systems (unaided condition). The level of SNR is reported in dB.

Trial Locations

Locations (1)

University College London Hospitals

🇬🇧

London, United Kingdom

© Copyright 2025. All Rights Reserved by MedPath