Rod Shape Changing After Scoliosis Correction Surgery
- Conditions
- Scoliosis, SevereScoliosis Idiopathic
- Interventions
- Diagnostic Test: 3D ScanningDiagnostic Test: EOS 2D/3D scanning
- Registration Number
- NCT05033171
- Lead Sponsor
- University of Pecs
- Brief Summary
The change of the fixation-rod after posterior srew-rod fixation segmentdesis is not widely known. The recent development of the 3D scanning technics and the opportunities of the EOS 2D/3D system made us possible to have the exact rod shape immediately after implantation, and at each control examination. These progressions made us available to follow up the shape changing of the fixation-rod, hereby the changing of the correction.
- Detailed Description
The adolescent idiopathic scoliosis can affect the 0,5-2% of the European population. One of the widely accepted treatment of severe scoliosis (Cobb angle is over 40-50°, or more than 10° progression observed a year) is posterior correction segmentdesis with screw and rod instrumentation. As a scoliosis treatment center, about 90-110 scoliosis correction surgeries are performed in our department, using conventional preoperative planning, coronal and sagittal translation technique from posterolateral approach.
An EOS 2D/3D system is available in our department making possible the scanning of the patient with upright biplanar ultra-low dose x-rays technique. The SterEOS software makes us possible to reconstruct the surface of the spine, pelvis and lower limb. The biplanar modality of the images makes possible to 3D reconstruct any simple shape using CAD (computer-aided design) softwares.
The recent updates in the 3D scanning technology also made us possible to perform intraoperative scannings without harming the sterility.
The aim of the study to define the change of the fixation-rod's shape after scoliosis correction surgery.
Main hypothesis: there is significant change in the rod shape after implantation
Secondary hypothesis 1: during the implant of the rod, it will loose from the prebent correction depending of the severity and rigidity of the curve.
Secondary hypothesis 2: in the early stage of the rehabilitation, after the mobilization the shape of the rod (and the spinal parameters) can change Secondary hypothesis 3: after the 3. month postoperatively the shape of rod does not change anymore
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 10
- routine patient care of University of Pécs Medical School Department of Orthopaedics
- diagnosed idiopathic adolescent scoliosis
- scoliosis induced surgical indication (Cobb-degree>45)
- early onset or adult degenerative scoliosis
- scoliosis with known origin
- the angle of the curve does not reach the criteria of surgical indication (Cobb-degree<45)
- former spine surgery
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- SINGLE_GROUP
- Arm && Interventions
Group Intervention Description Study group 3D Scanning Patients with scoliosis induced surgical indication (Cobb-degree\>45). * Posterior screw-rod fixation segmentdesis * Before the implantation, right after the implantation and after the in situ bending 3D scanning of the rod using Artec Eva Spider type manual 3D scanner will be performed. Scanning is possible from a more than 60 cm distance, so that means the operational area stays sterile. * EOS Micro Dose imaging will be done on the third day after surgery, on the third, the sixth, the twelfth and twenty fourth month after surgery (as in the actual clinical protocal). Study group EOS 2D/3D scanning Patients with scoliosis induced surgical indication (Cobb-degree\>45). * Posterior screw-rod fixation segmentdesis * Before the implantation, right after the implantation and after the in situ bending 3D scanning of the rod using Artec Eva Spider type manual 3D scanner will be performed. Scanning is possible from a more than 60 cm distance, so that means the operational area stays sterile. * EOS Micro Dose imaging will be done on the third day after surgery, on the third, the sixth, the twelfth and twenty fourth month after surgery (as in the actual clinical protocal).
- Primary Outcome Measures
Name Time Method Shape changing of the rod 2 years The fitted 3D models of the implanted rod right after implantation, 3 day, than 3-6-12-24 months after the surgery
- Secondary Outcome Measures
Name Time Method
Trial Locations
- Locations (1)
Ádám Schlégl
🇭🇺Pécs, Baranya, Hungary