Ultrasound Imaging of Quadriceps Muscle in Patients With Knee Osteoarthritis: Reliability of Echo Intensity Measurement
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 30
- 试验地点
- 1
- 主要终点
- Muscle Echogenicity Assessment ( Physiological parameter)
研究概览
简要总结
Echo intensity (EI) assessment using ultrasonography helps monitoring disease-induced muscle quality changes. However, there are no study investigating the reliability of EI in patients with knee osteoarthritis (OA). The primary aim of the present study was to investigate the inter and intra-rater reliability of EI evaluation by grayscale histogram analysis of quadriceps femoris muscle in patients with knee OA. The second aim was to compare the mean grayscale values obtained using both the Free Hand Tool (FHT) and Rectangular Marquee Tool (RMT) methods in ImageJ. Thirty patients with knee OA were included in this cross-sectional study. The echogenicity measurements of the Rectus Femoris, Vastus Inter-medius, Vastus Lateralis and Vastus Medialis were performed by two different researchers. Reliability analysis of EI measurements were calculated with using intraclass correlation coefficient (ICC), standard error of measurement (SEM) and coefficient of variation (CV) and Bland and Altman plot analysis.
研究设计
- 研究类型
- Observational
- 观察模型
- Cohort
- 时间视角
- Prospective
入排标准
- 年龄范围
- 40 Years 至 65 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Patients had tibiofemoral joint OA in at least one knee according to the American College of Rheumatology classification criteria with knee pain most days of the past month and osteophytes apparent on knee radiograph were included to the study
排除标准
- •Patients were excluded if they had a history of lower limb joint replacement and fracture, rheumatoid arthritis, diabetic neuropathy or polyneuropathy, and cardiovascular and neuromuscular problems.
结局指标
主要结局
Muscle Echogenicity Assessment ( Physiological parameter)
时间窗: Thirty minute
Muscle echogenicity assessed by using ultrasound. Ultrasound assessment was performed on rectus femoris (RF), vastus intermedius (VI), vastus medialis (VM) and vastus lateralis (VL) muscles using with an ultrasound-imaging device (Philips Medical Systems EPIQ 5 Release 5.0.2, Amsterdam). Ultrasound Brightness mode (B-mode) with musculoskeletal scanning and a multi-frequency linear transducer (8-12 MHz, code: eL18-4) were used. For calculating echogenicity of muscles; all images obtained ultrasonography were analysed using the Image J software (Version 1.48v, National Institutes of Health, Bethesda, MD, USA) by two different analysers (five years and one-year of experience in US image analysis). The echogenicity results of the muscles performed by the two researchers recorded.
次要结局
未报告次要终点
研究者
MERVE KARAPINAR
Research Assisstant, Physiotherapist
Suleyman Demirel University
