Non-invasive Continuous Total Hemoglobin Measurement by Pulse CO-Oximetry
- Conditions
- Transcutaneous Continuous Hemoglobin Measurement
- Registration Number
- NCT04506957
- Lead Sponsor
- Klinik Hirslanden, Zurich
- Brief Summary
This study is a data collection/sampling project for transcutaneous continuous Pulse CO-Oximetry and accessories (SW-Version Radical-7® Pulse CO-Oximeter with the Masimo rainbow SETTM, V1.6.2.4i Masimo Corp., Irvine, CA, USA, and the RD rainbow SET-2, Rev-O Fingersensor). The device received the CE Mark in 2012 and is approved by the Swiss Medic for clinical use. The Radical-7 device isolates multiple (7+) wavelengths of light of arterial signals using adaptive filters. It provides continuous noninvasive monitoring of arterial oxygen saturation (RadSpO2), pulse rate (RadPR), carboxyhaemoglobin saturation (SpCO), methaemoglobin saturation (SpMET), total haemoglobin concentration in g/dl (SpHb) and/or respiration rate (RRa). Additionally, Low Signal IQ (Low SIQ), Perfusion Index (PI), Pleth Variability Index (PVI), total arterial oxygen content (SpOC), Haematocrit (SpHCT), Signal identification Quality (SIQa), Respiration Indicator (RI) are displayed.The purpose of this prospective study is to investigate the reliability of non-invasive continuously measured SpHb by the Masimo Radical-7® Pulse co-oximeter (Radical 7 device) under steady state conditions by comparison against simultaneously invasive measured arterial haemoglobin concentrations (CoOxHb) in major spine surgery patients, in which high blood loss was expected
- Detailed Description
The objective of this investigation is the comparison of CoOxHb, HCT and SaO2 values of a blood gas analyzer (ABL 825, Radiometer Medical A/S) with simultaneously measured SpHb values of the Radical 7 device during the procedure of major spine surgery.
The primary endpoint of the study is the reliability of SpHb to detect CoOxHb and its changes during the process Secondary endpoint is the reliability of RadSpO2, RadPR, SpHCT and SpMET to detect SaO2, PR, HCT and MetHb and its changes during the process.
Inclusion criteria:
1. Patients scheduled for major spine surger
2. Age 18 years and older
3. Written consent of the participation after clarification about the study
Exclusion criteria:
1. No consent to participate
2. No German comprehension
3. Black skin patients
4. Patients with COVID-19 illness All patients were monitored based on the institutional routine monitoring for major spine surgery (continuous 2-channel electrocardiogram, a continuous invasive arterial blood pressure monitoring via fluid-filled cather system, inserted in the radial artery mainly of the non-dominant hand, SpO2, and in the case of high-risk patient a triple-lumen central venous line). Then a single use finger sensor (MasimoSet RD rainbow SET SpHb SpMet-Sensor) is attahed to the ring finger of the hand, where the catheter is introduced in the radial artery.
During the surgery routinely, arterial blood samples are drawn before induction of Anaesthesia, every 45 min and after acute blood loss during surgery. With each blood sample for a blood gas analysis the SpHb, SpMet, PI, PVI and the low SQI are recorded.
No additional blood sampling is necessary to perfom this investigation
50 patients will be included and the duration of the study is 24 month's Sample size calculation was performed with the StatsDirect Statistical Software Version 2.8.0 2013 (StatsDirect Ltd, Altrincham, UK) and revealed a sample size of 95 paired SpHb and CoOxHb measurements to achieve a power of 0.9, α = 0.05 to detect a mean difference (bias) of CoOxHb and SpHb of 0.50 g/dl with an estimated standard deviation (SD) of 1.0g/dl. The mean difference is determined based on previous investigations. Continuous variables are tested for normal distribution with the Kolmogorov-Smirnow test. Normally distributed data are expressed as mean ± standard deviation (SD); median, interquartile range (IQR ; 25th to 75th percentile) and \[maximum\] are specified when the data were not normally distributed. Categorical variables are presented as number and percentage (%). For subgroup analysis continuous variables are compared using the t-test or Mann-Whitney U test, when appropriate. All tests are two-sided and a P-value \< 0.05 was determined to be significant.
For all determinants that might have an impact on the fault detection of the SpHb stepwise multiple regressions analysis was performed. Correlation is evaluated by Spearman rank test. To determine agreement of the methods, the Bland Altman analysis for repeated measurements is performed for SpHb and CoOcHb.
Recruitment & Eligibility
- Status
- UNKNOWN
- Sex
- All
- Target Recruitment
- 50
- Patients scheduled for major spine surgery
- Written consent of the participation after clarification about the study
- No consent to participate
- No German comprehension
- Black skin patients
- Patients with COVID-19 illness
Study & Design
- Study Type
- OBSERVATIONAL
- Study Design
- Not specified
- Primary Outcome Measures
Name Time Method Reliability of SpHb to detect CoOxHb and its changes 24 months Co-oximetry hemoglobin values from blood gas analyzer is simultaneous compared with the transcutaneous detected SpHb (Pulse CO-Oximetry hemoglobin measurement). Linear correlation and Bland Altman Analysis are performed for analysis these data pairs
- Secondary Outcome Measures
Name Time Method