Left Atrial Appendage Closure With the LAmbre
- Conditions
- Atrial FibrillationLeft Atrial Appendage ClosureStroke
- Interventions
- Device: LAA closure with LAmbre
- Registration Number
- NCT03147391
- Lead Sponsor
- Shanghai 10th People's Hospital
- Brief Summary
The study was to retrospectively analyse the efficacy and safety of LAA closure using the LAmbre in our center from April 2014 to November 2015.
- Detailed Description
The study was to retrospectively analyse the efficacy and safety of percutaneous left atrial appendage (LAA) closure using the LAmbre (Lifetech Scientific Co., Ltd., Shenzhen, China) in our center from April 2014 to November 2015. 89.4% has finished the 12-month esophageal ecllocardiogrhy (TEE) examination. The average followup was 2-years.
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 66
- Patient is ≥18 years of age;
- Chronic atrial fibrillation ≥3 months; paroxysmal, persistent or permanent non-valvular AF;
- CHADS2-VAS score 2 or higher;
- Patient can understand the trial purpose, voluntarily join this clinical trial with informed consent;
- Patient voluntarily completes the follow-up and follow-up inspection in accordance with the clinical trials process.
• A. Clinical exclusion criteria
- Presence of rheumatic, degenerative or congenital valvular heart diseases,
- The diameter of left atrial ≥65 mm;
- LAA size < 12mm or > 30 mm
- Left atrium has been removed;
- Heart transplantation patients;
- Symptomatic patients with carotid artery disease (such as carotid stenosis ≥ 50%);
- Acute myocardial infarction or unstable angina;
- Decompensated heart failure (New York Heart Association functional class III-IV);
- Recent myocardial infarction (< 3 months);
- Patients with an atrial septal defect or received an atrial septal occluder. The patient has an ablation procedure planned within 30 days of potential LAmbre Occluder implant
- The patient has a planned cardioversion 30 days post implant of the LAmbre Occluder
- Patient who after artificial mechanical heart valve replacement operation;
- Uncontrolled Heart rate ≥ 110 beats / min17) History stroke or TIA within 30 days;
- Presence of complex aortic plaque(4mm) in ascending aorta;
- Cardiac tumors or other malignancy with estimated life expectancy u less than 2 years;
- Have thrombocytopenia (platelet 《105 / μl) or anemia(Hb<10g/dl);
- Women who is pregnancy or plan to pregnancy during the trial period;
- Presence of active sepsis or endocarditis;
- Patient participated in the other trials;
- The investigators expect the patient not be able to complete the trial according to requirements.
B. Esophageal ultrasonic exclusion criteria
- LVEF≤30%;
- Presence of left atrial appendage thrombus;
- High risk PFO patients(presence of atrial septal aneurysm);
- Have obvious mitral valve stenosis (the area of mitral valve≤ 2 cm2);
- Have obvious and unexplained pericardial effusion(≥4 cm2).
- Presence of complex aortic plague(≥4 mm) in ascending aorta.
Study & Design
- Study Type
- OBSERVATIONAL
- Study Design
- Not specified
- Arm && Interventions
Group Intervention Description LAA closure with LAmbre LAA closure with LAmbre The patients with atrial fibrillation who received left atrial appendage (LAA) closure using the LAmbre device in our center from April 2014 to November 2015.
- Primary Outcome Measures
Name Time Method Ischemic stroke up to 5 years Ischemic stroke
- Secondary Outcome Measures
Name Time Method The composite safety and efficacy end-points up to 5 years all-cause death, stroke, major bleeding, thromboembolism, device related severe complications
Successful sealing of the LAA up to 5 years successful sealing around the device at the LAA orifice (residual jet flow of \< 5 mm) as measured by transesophageal echocardiogram (TEE) at 6 months after device implantation