跳至主要内容
临床试验/NCT02308566
NCT02308566已完成4 期

Aortic Valve Replacement Using Closed Extracorporeal Circuit. Minimized Versus Conventional Extracorporeal Circulation Technique: Qualitative Differences

Insel Gruppe AG, University Hospital Bern2 个研究点 分布在 1 个国家目标入组 48 人开始时间: 2011年6月最近更新:
适应症

试验速览

阶段
4 期
状态
已完成
入组人数
48
试验地点
2
主要终点
Total and interval-related cerebral microembolic load as measured by transcranial Doppler

研究概览

简要总结

In this study, the investigators aim to compare cerebral embolic load in patients undergoing surgical aortic valve replacement using either the minimized extracorporeal circulation or the conventional extracorporeal circulation technique. The detection of cerebral emboli is performed not-invasively by transcranial Doppler detection of high-intensity transient signals representing solid or gaseous microembolism in the middle cerebral arteries. The investigators hope to get more insight in the mechanism (incl. quantity) of cerebral embolism during aortic valve surgery using extracorporeal circulation.

详细描述

Background

The gold standard to treat severe aortic valve stenosis is currently the surgical aortic valve replacement (SAVR) using conventional extracorporeal circulation (CECC). SAVR, however, can be performed also on minimized extracorporeal circulation (MECC), which is characterized by reduced priming volume and interfaces between blood and artificial surfaces and blood-air interface, respectively. Further technical developments of the MECC system together with reports on less induction of the coagulation cascade and activation of inflammatory systemic response may account for a reduced incidence of microbubble generation with MECC system.

Objective

The aim of the is to investigate the procedural-related incidence of high-intensity transient signals (HITS) representing solid or gaseous microembolism reaching the cerebral vessels.

Methods

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 80 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Isolated Severe Aortic Valve Stenosis
  • No other cardiac disease
  • No other coronary heart disease
  • Written informed consent
  • Exclusion Criteria
  • Double valve surgery
  • Concomitant coronary artery bypass surgery
  • Vascular surgery
  • Age < 18 yrs.
  • Age > 80 yrs.

排除标准

  • 未提供

结局指标

主要结局

Total and interval-related cerebral microembolic load as measured by transcranial Doppler

时间窗: Intraoperative period (start surgical procedure to skin suture, duration approx. 4 hrs)

次要结局

  • Cerebral complications, e.g. delirium and stroke as detected clinically(In-hospital period (until hospital discharge, duration approx. 7-10 days))
  • Redo surgery(In-hospital period (until hospital discharge, duration approx. 7-10 days))
  • In-hospital Mortality(In-hospital period (until hospital discharge, duration approx. 7-10 days))
  • Extubation time(In-hospital period (until hospital discharge, duration approx. 7-10 days))
  • In-hospital infections(In-hospital period (until hospital discharge, duration approx. 7-10 days))
  • ICU length of stay(In-hospital period (until hospital discharge, duration approx. 7-10 days))
  • Thromboembolic complications(In-hospital period (until hospital discharge, duration approx. 7-10 days))

研究者

申办方类型
Other
责任方
Sponsor

研究点 (2)

Loading locations...

相似试验